distribution network structure backup tie line distribution
本文關(guān)鍵詞:基于環(huán)間聯(lián)絡(luò)和配電自動(dòng)化的配電網(wǎng)高可靠性設(shè)計(jì)方案,由筆耕文化傳播整理發(fā)布。
基于環(huán)間聯(lián)絡(luò)和配電自動(dòng)化的配電網(wǎng)高可靠性設(shè)計(jì)方案
A Design Scheme of High-Reliable Distribution Network Based on Tie Line Between Ring-Shaped Distribution Networks and Distribution Automation
[1] [2] [3] [4]
SONG Ruochen, XU Wenjin, YANG Guang, GU Liqiang (State Grid Shanghai Municipal Electric Power Company, Pudong New District, Shanghai 200122, China)
國(guó)網(wǎng)上海市電力公司,上海市浦東新區(qū)200122
文章摘要:針對(duì)傳統(tǒng)單環(huán)網(wǎng)結(jié)構(gòu)無(wú)法滿足城市重點(diǎn)地區(qū)供電可靠性要求,同時(shí)雙環(huán)網(wǎng)結(jié)構(gòu)在舊城區(qū)難以實(shí)現(xiàn)的問(wèn)題,提出基于環(huán)間聯(lián)絡(luò)和配電自動(dòng)化的配電網(wǎng)設(shè)計(jì)方案。環(huán)間聯(lián)絡(luò)表示在2回電纜環(huán)網(wǎng)之間增設(shè)1路備用聯(lián)絡(luò)線的網(wǎng)架優(yōu)化方案。通過(guò)概率分布建模和計(jì)算,研究了環(huán)間聯(lián)絡(luò)線對(duì)負(fù)荷轉(zhuǎn)移能力的影響?紤]聯(lián)絡(luò)線效用、重要負(fù)荷保障、投資建設(shè)成本3個(gè)因素,討論了聯(lián)絡(luò)線落點(diǎn)位置的選擇原則。為充分發(fā)揮環(huán)間聯(lián)絡(luò)結(jié)構(gòu)的負(fù)荷轉(zhuǎn)移能力優(yōu)勢(shì),并降低故障處理時(shí)長(zhǎng),提出集中式和分布式協(xié)調(diào)配合的配電自動(dòng)化設(shè)計(jì)方案,包括詳細(xì)動(dòng)作邏輯。最后,基于樣本停電數(shù)據(jù)的可靠性分析結(jié)果驗(yàn)證了本設(shè)計(jì)方案的有效性,并比較了網(wǎng)架結(jié)構(gòu)優(yōu)化和配電自動(dòng)化各自的應(yīng)用效果和投資回報(bào)率。
Abstr:In allusion to the troubles that traditional distribution network with ring-shaped structure cannot meet the demand on power supply reliability for urban key regions and dual-ring-shaped structure is difficult to be implemented in old towns, a distribution network design scheme based on tie line between ring-shaped networks and distribution automation is proposed, where tie line between ring-shaped networks means that a backup tie line is added between two ring-shaped networks to optimize the network structure. Through modeling of probability distribution and calculation, the impacts of tie line between ring-shaped networks on load-transferring capability are researched. Considering three factors such as the utility of the tie line, ensuring power supply for important loads and investment on construction, the principles to position the tie line are discussed. To bring the tie line's superiority of load-transferring capability into full play and shorten the time for fault processing, a distribution automation scheme, in which the centralized and distributed fault processing are coordinated, is put forward along with detailed action logics. Finally, the results of reliability analysis based on sampled power supply interruption data validate the effectiveness of the proposed design scheme, and respective application effects as well as the return on investment(ROI) of network structure optimization and distribution automation are compared.
文章關(guān)鍵詞:
Keyword::distribution network structure backup tie line distribution automation reliability analysis