換熱站遠(yuǎn)程監(jiān)控系統(tǒng)的研究與應(yīng)用
本文選題:換熱站 切入點(diǎn):遠(yuǎn)程 出處:《山東大學(xué)》2017年碩士論文 論文類型:學(xué)位論文
【摘要】:隨著工業(yè)的快速進(jìn)步,以及人們環(huán)保意識的提高,集中供暖逐漸代替?zhèn)鹘y(tǒng)的分散鍋爐房供暖。換熱站是集中供暖系統(tǒng)中的關(guān)鍵一環(huán),連接著熱廠與熱用戶,其工作情況直接影響了供熱的質(zhì)量。集中供暖系統(tǒng)中換熱站分布較為分散,依靠人力進(jìn)行每日巡檢和抄表,不僅浪費(fèi)人力,還不能及時(shí)獲取換熱站的工作情況。因此需要設(shè)計(jì)一套換熱站遠(yuǎn)程監(jiān)控系統(tǒng)。目前國內(nèi)大都直接購買大型監(jiān)控軟件,雖然能夠滿足需求,但是對于中小型熱力公司來說成本較高,而且功能繁多,占用大量系統(tǒng)資源,操作復(fù)雜,工作人員無法直接上手。本文采用VS2013作為主要開發(fā)環(huán)境,使用組態(tài)軟件開發(fā)技術(shù)、COM組件、線程池、以及GPRS通信等技術(shù)對換熱站遠(yuǎn)程監(jiān)控系統(tǒng)進(jìn)行了開發(fā)。本文首先對換熱站遠(yuǎn)程監(jiān)控系統(tǒng)進(jìn)行了需求分析,給出了遠(yuǎn)程監(jiān)控系統(tǒng)的整體設(shè)計(jì)方案。根據(jù)功能的不同,采用模塊化設(shè)計(jì)思想,將整個(gè)換熱站遠(yuǎn)程監(jiān)控系統(tǒng)劃分為組態(tài)系統(tǒng)、數(shù)據(jù)存儲中心和運(yùn)行系統(tǒng)三大功能模塊。在明確各模塊的設(shè)計(jì)任務(wù)后,介紹了在進(jìn)行系統(tǒng)開發(fā)時(shí)所用到的關(guān)鍵技術(shù)。組態(tài)系統(tǒng)是進(jìn)行二次開發(fā)的平臺。基于組態(tài)開發(fā)技術(shù),為用戶提供了一個(gè)拖拽式的定制環(huán)境,用戶可以根據(jù)需要對遠(yuǎn)程監(jiān)控系統(tǒng)進(jìn)行組態(tài)與管理,包括數(shù)據(jù)庫組態(tài)、畫面組態(tài)、報(bào)表組態(tài)以及用戶權(quán)限管理;诠S設(shè)計(jì)模式和動態(tài)鏈接庫技術(shù)對畫面組態(tài)模塊進(jìn)行了設(shè)計(jì)與開發(fā)。采用基于角色的訪問控制模型進(jìn)行用戶權(quán)限管理模塊的設(shè)計(jì)。數(shù)據(jù)存儲中心是連接組態(tài)系統(tǒng)和運(yùn)行系統(tǒng)的橋梁,是系統(tǒng)各模塊的數(shù)據(jù)共享中心,保存了組態(tài)信息和運(yùn)行數(shù)據(jù)信息。存儲的數(shù)據(jù)從時(shí)間上分為實(shí)時(shí)數(shù)據(jù)和歷史數(shù)據(jù)。數(shù)據(jù)存儲中心的開發(fā)首先對常用的數(shù)據(jù)庫進(jìn)行比較,選擇合適的實(shí)時(shí)數(shù)據(jù)庫,然后基于FastDB磁盤模式對實(shí)時(shí)數(shù)據(jù)庫進(jìn)行數(shù)據(jù)表的設(shè)計(jì),采用COM組件技術(shù)實(shí)現(xiàn)數(shù)據(jù)庫訪問接口,最后對歷史數(shù)據(jù)的轉(zhuǎn)儲進(jìn)行設(shè)計(jì),將歷史數(shù)據(jù)以二進(jìn)制的形式,串行化到dat文件中,采用多級目錄的方式存儲歷史文件。運(yùn)行系統(tǒng)是實(shí)現(xiàn)換熱站遠(yuǎn)程監(jiān)控的核心部分,包括數(shù)據(jù)通信層、系統(tǒng)表示層、遠(yuǎn)端訪問層。本文采用GPRS通信技術(shù)實(shí)現(xiàn)了各換熱站與系統(tǒng)的遠(yuǎn)程數(shù)據(jù)交互。以畫面、報(bào)表等形式直觀地展現(xiàn)換熱站的實(shí)時(shí)工作狀態(tài),同時(shí)參數(shù)設(shè)置的功能實(shí)現(xiàn)了換熱站的遠(yuǎn)程控制;贕SM/SMS技術(shù)和短信貓實(shí)現(xiàn)了報(bào)警短信推送服務(wù)。在Web服務(wù)器的基礎(chǔ)上設(shè)計(jì)了遠(yuǎn)端訪問層,實(shí)現(xiàn)了可以通過瀏覽器訪問數(shù)據(jù)庫的功能。最后通過對換熱站遠(yuǎn)程系統(tǒng)的功能和性能測試,證明了本設(shè)計(jì)方案的可行性,能夠?qū)崿F(xiàn)預(yù)期目標(biāo),滿足換熱站監(jiān)控的需求。
[Abstract]:With the rapid progress of industry and the improvement of people's awareness of environmental protection, central heating is gradually replacing the traditional decentralized boiler room heating. The heat exchange station is a key link in the central heating system, connecting the heat plant with the thermal users. The working conditions directly affect the quality of heating. The distribution of heat exchange stations in the central heating system is scattered, and it is not only a waste of manpower to carry out daily inspection and meter reading by manpower, It is necessary to design a remote monitoring system for heat transfer stations. At present, most of the domestic direct purchase of large-scale monitoring software, although can meet the demand, However, for the small and medium-sized thermal companies, the cost is high, the functions are various, they occupy a large number of system resources, the operation is complex, and the staff can not directly use it. This paper adopts VS2013 as the main development environment. The remote monitoring system of heat exchange station is developed by using configuration software development technology, such as com component, thread pool and GPRS communication, etc. Firstly, the requirement of remote monitoring system of heat exchange station is analyzed in this paper. The whole design scheme of the remote monitoring system is given. According to the different functions, the remote monitoring system of the heat transfer station is divided into configuration system by adopting the modular design idea. After defining the design tasks of each module, the key technologies used in system development are introduced. Configuration system is the platform for secondary development, and is based on configuration development technology. It provides a custom environment of drag-and-drop type for the user. The user can configure and manage the remote monitoring system according to the need, including database configuration, picture configuration, Report configuration and user rights management. Based on the factory design pattern and dynamic link library technology, the picture configuration module is designed and developed. The role-based access control model is used to set up the user authority management module. Data storage center is the bridge between configuration system and operation system, It is the data sharing center of every module of the system, which saves the configuration information and the running data information. The stored data is divided into real-time data and historical data in time. The development of the data storage center first carries on the comparison to the commonly used database. Select the appropriate real-time database, then based on the FastDB disk mode to design the real-time database data table, using the COM component technology to realize the database access interface, and finally to the historical data dump design, The history data is serialized into the dat file in binary form, and the history file is stored by multilevel directory. The running system is the core part of the remote monitoring of heat transfer station, including the data communication layer, the system presentation layer, the data communication layer and the system presentation layer. Remote access layer. In this paper, GPRS communication technology is used to realize the remote data interaction between the heat transfer stations and the system. The real-time working state of the heat transfer stations is displayed intuitively in the form of pictures and reports. At the same time, the function of parameter setting realizes the remote control of heat exchange station. Based on GSM/SMS technology and short message cat, the alarm short message push service is realized. The remote access layer is designed on the basis of Web server. Finally, by testing the function and performance of the remote system of heat exchange station, the feasibility of the design scheme is proved, and the expected goal can be achieved and the monitoring needs of the heat transfer station can be satisfied.
【學(xué)位授予單位】:山東大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2017
【分類號】:TP277
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 嵇啟春;李金;朱京衛(wèi);;換熱站節(jié)能改造[J];工業(yè)控制計(jì)算機(jī);2010年10期
2 錢漢成,王剛,徐天大,趙亮,張曉梅,郭幼農(nóng);大規(guī)模換熱站微機(jī)控制系統(tǒng)[J];自動化與儀表;2004年02期
3 臧磊真;馬思樂;;變頻器在城市供暖換熱站中的應(yīng)用[J];變頻器世界;2006年08期
4 聞犁;構(gòu)建節(jié)能省錢的換熱站自控系統(tǒng)[J];電氣時(shí)代;2005年06期
5 李軒青;劉輝;;基于研華模塊與觸摸屏的換熱站監(jiān)控系統(tǒng)[J];山西電子技術(shù);2010年05期
6 付淵;付繼宗;陳文星;;計(jì)算機(jī)監(jiān)控系統(tǒng)在無人值守?fù)Q熱站中的應(yīng)用[J];電腦開發(fā)與應(yīng)用;2012年03期
7 周曉陽;何佳;;集中供熱換熱站的優(yōu)化及運(yùn)行探討[J];科技傳播;2014年04期
8 張友兵;張海蓉;胡東力;;全廠換熱站現(xiàn)場無人值守設(shè)計(jì)的實(shí)現(xiàn)[J];儀器儀表用戶;2014年02期
9 林舒宜;張炳偉;;集中供熱智能無人值守?fù)Q熱站自控系統(tǒng)的設(shè)計(jì)與實(shí)現(xiàn)[J];自動化與儀表;2013年09期
10 王彩俠;杜成偉;;換熱機(jī)組節(jié)能改造應(yīng)用[J];科技傳播;2012年02期
相關(guān)會議論文 前9條
1 孫玉慶;孫毅;;關(guān)于換熱站規(guī)模的經(jīng)濟(jì)分析[A];新世紀(jì) 新機(jī)遇 新挑戰(zhàn)——知識創(chuàng)新和高新技術(shù)產(chǎn)業(yè)發(fā)展(下冊)[C];2001年
2 吳鶯;王順利;;換熱站的設(shè)計(jì)[A];土木建筑學(xué)術(shù)文庫(第13卷)[C];2010年
3 牟林朋;王俊;;換熱站無線遠(yuǎn)程監(jiān)控系統(tǒng)[A];推進(jìn)供熱體制改革與節(jié)能改造新技術(shù)新設(shè)備應(yīng)用交流會論文集[C];2010年
4 董玉平;閻宇宏;武秉禮;張芫;;某工業(yè)廠區(qū)換熱站系統(tǒng)設(shè)計(jì)[A];全國暖通空調(diào)制冷2010年學(xué)術(shù)年會資料集[C];2010年
5 馮永華;;供熱系統(tǒng)換熱站主要設(shè)備選型應(yīng)注意的問題[A];2007年山東省制冷空調(diào)學(xué)術(shù)年會論文集[C];2007年
6 白海波;侯永亮;;利用高爐廢熱采暖存在問題的分析及處理[A];河北省冶金學(xué)會冶金設(shè)備學(xué)術(shù)年會會議論文集[C];2013年
7 付玉龍;;智能化板式換熱機(jī)組在集中供熱中的應(yīng)用[A];土木工程建造管理(6)[C];2011年
8 遲軍為;王俊;;無線射頻測溫系統(tǒng)在供暖溫度監(jiān)測中的應(yīng)用[A];推進(jìn)供熱體制改革與節(jié)能改造新技術(shù)新設(shè)備應(yīng)用交流會論文集[C];2010年
9 白海波;侯永亮;;利用高爐廢熱采暖存在問題的分析及處理[A];第七屆全國能源與熱工學(xué)術(shù)年會論文集[C];2013年
相關(guān)重要報(bào)紙文章 前10條
1 本報(bào)記者 王俊美 通訊員 李杰;建設(shè)新熱源 整合換熱站[N];淄博日報(bào);2009年
2 楊湘營 劉俊偉;給換熱站戴上“緊箍” 規(guī)范山東青州供熱發(fā)展[N];中國建設(shè)報(bào);2010年
3 任永科;督導(dǎo)完成換熱站工程[N];中國航天報(bào);2011年
4 華南;市府領(lǐng)導(dǎo)分別與相關(guān)部門座談排查災(zāi)情進(jìn)一步部署抗災(zāi)工作[N];營口日報(bào);2007年
5 地區(qū)糾風(fēng)辦供稿;年內(nèi)新建三座換熱站[N];塔城報(bào);2009年
6 沈河區(qū)太清宮街城中小區(qū) 王文良;換熱站是供暖好壞的關(guān)鍵點(diǎn)[N];沈陽日報(bào);2009年
7 劉子昂 吳晶瑩;一場攻堅(jiān)戰(zhàn)的考驗(yàn)[N];經(jīng)理日報(bào);2008年
8 李明旭 記者肖萌;丹麥新技術(shù)助熱電總公司節(jié)電48.25%[N];錦州日報(bào);2009年
9 記者 曹雷 通訊員 王鑄;商河城區(qū)供熱新增5個(gè)換熱站[N];濟(jì)南日報(bào);2011年
10 記者 王濤;切實(shí)加強(qiáng)領(lǐng)導(dǎo) 嚴(yán)格工作流程 確保如期供熱[N];呂梁日報(bào);2013年
相關(guān)博士學(xué)位論文 前1條
1 楊先亮;集中供熱系統(tǒng)運(yùn)行方式及管網(wǎng)泄漏檢測研究[D];華北電力大學(xué);2015年
相關(guān)碩士學(xué)位論文 前10條
1 薛海松;基于故障樹的無人值守?fù)Q熱站監(jiān)控技術(shù)研究[D];燕山大學(xué);2015年
2 朱昭璐;基于氣候補(bǔ)償器的園區(qū)換熱站供熱控制系統(tǒng)研究[D];西安建筑科技大學(xué);2015年
3 鄺濤;上灣換熱站節(jié)能控制系統(tǒng)設(shè)計(jì)與研究[D];西安建筑科技大學(xué);2015年
4 丁紅亮;某片區(qū)換熱站優(yōu)化實(shí)踐及供熱系統(tǒng)智能化控制策略研究[D];山東建筑大學(xué);2015年
5 孫勇;工業(yè)遠(yuǎn)程控制下的熱網(wǎng)自動控制系統(tǒng)[D];大連海事大學(xué);2015年
6 杜鑫;遠(yuǎn)程無人值守?fù)Q熱站控制系統(tǒng)的設(shè)計(jì)[D];大連交通大學(xué);2015年
7 高曉宇;基于數(shù)據(jù)挖掘的換熱站運(yùn)行規(guī)律研究[D];河北工業(yè)大學(xué);2015年
8 董如彬;基于s7-1200PLC的水水換熱站分布式系統(tǒng)設(shè)計(jì)[D];山東大學(xué);2015年
9 高闖;“一補(bǔ)二”箱體式換熱站[D];太原理工大學(xué);2012年
10 袁孝勇;換熱站監(jiān)控系統(tǒng)設(shè)計(jì)及研究[D];青島科技大學(xué);2015年
,本文編號:1648919
本文鏈接:http://sikaile.net/kejilunwen/zidonghuakongzhilunwen/1648919.html