用于GERD診斷的膠囊式pH監(jiān)測(cè)系統(tǒng)的初步研發(fā)
本文關(guān)鍵詞: GERD pH值 CC2540 無(wú)線傳輸 應(yīng)用程序 出處:《南京航空航天大學(xué)》2016年碩士論文 論文類型:學(xué)位論文
【摘要】:近年來(lái),居民飲食結(jié)構(gòu)的變化導(dǎo)致胃食管反流病(Gastro Esophageal Reflux Disease,GERD)的發(fā)病率逐年上升。臨床醫(yī)學(xué)中,醫(yī)生通過(guò)鼻腔插入患者的食管下括約肌(Lower Esophageal Sphincter,LES)上5cm處一支pH監(jiān)測(cè)電極,與體外數(shù)據(jù)記錄儀相連以監(jiān)測(cè)患者食道pH值,從而確診GERD。這種pH監(jiān)測(cè)方法不僅會(huì)影響患者的生活、給患者的食管壁帶來(lái)不適,而且由于電極的移動(dòng)也會(huì)導(dǎo)致測(cè)量結(jié)果不夠準(zhǔn)確。本課題結(jié)合GERD診斷的現(xiàn)狀,基于可吞服電子膠囊(Swallow Electronic Capsule,SEC)這一概念,初步設(shè)計(jì)了一種用于GERD診斷的膠囊式pH監(jiān)測(cè)系統(tǒng)。論文的主要內(nèi)容包括:(1)綜合對(duì)比各種pH電極的性能,選擇復(fù)合玻璃電極作為測(cè)量電極并對(duì)其進(jìn)行了實(shí)驗(yàn)驗(yàn)證,實(shí)驗(yàn)表明其穩(wěn)定度好、準(zhǔn)確度高。(2)基于數(shù)據(jù)采集、處理、無(wú)線傳輸?shù)墓δ芤?選擇了TI公司的CC2540微控制芯片,以此芯片為核心設(shè)計(jì)并實(shí)現(xiàn)了上述功能一體化的采集系統(tǒng)。該系統(tǒng)可以進(jìn)行準(zhǔn)確的pH值監(jiān)測(cè)、實(shí)時(shí)的數(shù)據(jù)處理和同步的無(wú)線數(shù)據(jù)傳輸。(3)基于便攜遠(yuǎn)程醫(yī)療的理念,設(shè)計(jì)了基于Android系統(tǒng)的手機(jī)應(yīng)用程序,實(shí)現(xiàn)了來(lái)自CC2450的數(shù)據(jù)的無(wú)線接收、顯示和保存,并通過(guò)相關(guān)測(cè)試證明了所設(shè)計(jì)的應(yīng)用程序可以實(shí)現(xiàn)數(shù)據(jù)傳輸?shù)臏?zhǔn)確性。(4)設(shè)計(jì)了相關(guān)測(cè)試驗(yàn)方案驗(yàn)證了所搭建系統(tǒng)pH值測(cè)量的穩(wěn)定性和準(zhǔn)確性。最后,設(shè)計(jì)并完成了動(dòng)物(新西蘭兔)的在體實(shí)驗(yàn),表明所研發(fā)的用于GERD診斷的膠囊式pH監(jiān)測(cè)系統(tǒng)的初步可行性。本課題在GERD的診斷治療方面具有獨(dú)特應(yīng)用價(jià)值,通過(guò)以后的逐步完善有望應(yīng)用于臨床。此外,該項(xiàng)技術(shù)也可以為非醫(yī)學(xué)領(lǐng)域的pH監(jiān)測(cè)提供一種新的技術(shù)途徑。
[Abstract]:In recent years, the change of people's diet structure lead to gastroesophageal reflux disease (Gastro Esophageal Reflux Disease, GERD) incidence increased year by year. The clinical medicine, the doctor inserted through the nasal cavity in patients with lower esophageal sphincter (Lower Esophageal Sphincter, LES 5cm) on a pH monitor electrode is connected with the data logger to monitor patients with esophageal pH value, thus confirmed GERD. this pH monitoring method will not only affect the life of the patients, to patients with esophageal wall discomfort, and because the movement of the electrode will lead to the result is not accurate enough. This study combined the current status of GERD diagnosis, swallow capsules (Swallow Electronic Capsule, based on the concept of SEC) and the preliminary design for a capsule type pH monitoring system for the diagnosis of GERD. The main contents of this paper include: (1) the performance of comprehensive comparison of various pH electrode, composite glass electrode as measured The amount of electrode and verified the result of the experiment shows that the good stability and high accuracy. (2) based on data acquisition, wireless transmission, functional requirements, the company chose TI CC2540 micro control chip, the chip is used as the core design and implementation of the acquisition system. The system function integration for accurate pH monitoring, real-time data processing and wireless data transmission synchronization. (3) portable telemedicine based on the concept of the design of the Android system based on mobile phone application, realize the wireless receiving data from the CC2450, display and preservation, and proved the accuracy of the designed application can be achieved the data transmission through the relevant test. (4) design related test scheme is verified by building the system pH value measurement stability and accuracy. Finally, the design and completion of the animal (rabbit) in vivo experiment table For preliminary feasibility of capsule type pH monitoring system GERD in the diagnosis of the Ming development. This topic has a unique application value in the diagnosis and treatment of GERD, the future is expected to improve gradually in clinical application. In addition, provides a new approach for monitoring the pH technology also can be a non medical field.
【學(xué)位授予單位】:南京航空航天大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2016
【分類號(hào)】:R197.39
【參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 胡錦麗;;一種基于OSAL的STM32F103微處理器多任務(wù)作業(yè)調(diào)度機(jī)制[J];廊坊師范學(xué)院學(xué)報(bào)(自然科學(xué)版);2015年05期
2 張瑞娟;劉晴;;膠囊內(nèi)窺鏡產(chǎn)品發(fā)展現(xiàn)狀綜述[J];生物技術(shù)世界;2015年09期
3 Pedro Boal Carvalho;Bruno Rosa;Francisca Dias de Castro;Maria Joo Moreira;José Cotter;;PillCam COLON 2~ in Crohn's disease:A new concept of pan-enteric mucosal healing assessment[J];World Journal of Gastroenterology;2015年23期
4 張紅輝;羅海波;余新榮;丁慶海;;多點(diǎn)標(biāo)定的自適應(yīng)非均勻性校正方法[J];紅外與激光工程;2014年11期
5 湯進(jìn)芝;王雯;;胃食管反流病中食管pH檢測(cè)進(jìn)展[J];國(guó)際消化病雜志;2014年03期
6 李琳;;pH(酸度)計(jì)示值誤差測(cè)量值的不確定度評(píng)定[J];計(jì)量與測(cè)試技術(shù);2013年12期
7 趙凱;顏國(guó)正;王志武;姜萍萍;劉華;;人體胃腸道生理參數(shù)無(wú)創(chuàng)檢測(cè)系統(tǒng)及試驗(yàn)研究[J];載人航天;2013年03期
8 曹順;李金鳳;魏立峰;;基于PIC單片機(jī)的pH測(cè)試儀[J];儀表技術(shù)與傳感器;2012年10期
9 崔建國(guó);;消化道微型監(jiān)測(cè)電子膠囊的研究進(jìn)展[J];重慶理工大學(xué)學(xué)報(bào)(自然科學(xué));2012年09期
10 陳瑤;薛月菊;陳聯(lián)誠(chéng);陳漢鳴;王楷;黃珂;;pH傳感器溫度補(bǔ)償模型研究[J];傳感技術(shù)學(xué)報(bào);2012年08期
相關(guān)碩士學(xué)位論文 前8條
1 田丹;基于低功耗藍(lán)牙的移動(dòng)微網(wǎng)系統(tǒng)研究[D];浙江大學(xué);2014年
2 隋寶石;基于24小時(shí)pH值監(jiān)測(cè)分析的食管診斷系統(tǒng)研究[D];天津大學(xué);2012年
3 李曉華;基于pH值檢測(cè)智能釋藥電子膠囊的初步研究[D];重慶大學(xué);2011年
4 劉敏;移動(dòng)終端的Android移植與應(yīng)用程序設(shè)計(jì)[D];西安電子科技大學(xué);2011年
5 劉建青;基于OV6920人體無(wú)線膠囊內(nèi)窺鏡設(shè)計(jì)實(shí)驗(yàn)研究[D];華南理工大學(xué);2010年
6 趙霄;基于單片機(jī)的藍(lán)牙接口設(shè)計(jì)及數(shù)據(jù)傳輸?shù)膶?shí)現(xiàn)[D];北京交通大學(xué);2008年
7 董華;基于MSP430單片機(jī)的pH計(jì)的研制[D];吉林大學(xué);2008年
8 董勝敏;醫(yī)用微型玻璃電極的制備與性能[D];大連輕工業(yè)學(xué)院;2004年
,本文編號(hào):1537248
本文鏈接:http://sikaile.net/kejilunwen/yiqiyibiao/1537248.html