瑞利BOTDA系統(tǒng)小波降噪新方法
發(fā)布時(shí)間:2018-06-30 04:12
本文選題:提升小波 + 實(shí)時(shí)降噪。 參考:《半導(dǎo)體光電》2017年06期
【摘要】:基于瑞利散射的布里淵光時(shí)域分析系統(tǒng)(BOTDA)因?yàn)閱味巳肷涞奶匦远袕V泛的應(yīng)用前景。研究了應(yīng)用提升小波變換對傳感信號(hào)進(jìn)行降噪,與傳統(tǒng)小波變換相比,提升小波變換結(jié)構(gòu)簡單,運(yùn)算速度快,易于硬件實(shí)現(xiàn)。分別利用累加平均法、傳統(tǒng)小波變換和提升小波變換對瑞利BOTDA系統(tǒng)傳感信號(hào)進(jìn)行降噪,通過信噪比、均方誤差和計(jì)算時(shí)間對三種方法的降噪效果進(jìn)行比較。結(jié)果表明,累加平均法將信噪比提高了約14dB,傳統(tǒng)小波變換將信噪比提高了約18dB,計(jì)算速度是累加平均法的3.26倍。提升小波變換將信噪比提高了約19dB,計(jì)算時(shí)間僅為傳統(tǒng)小波變換的約60%。結(jié)果表明,提升小波變換適用于瑞利BOTDA系統(tǒng)實(shí)時(shí)降噪處理。
[Abstract]:The signal - to - noise ratio ( SNR ) is improved by about 14dB , and the signal - to - noise ratio ( SNR ) of the traditional wavelet transform is improved by about 18 dB . The signal - to - noise ratio ( SNR ) of the traditional wavelet transform is improved by about 19 dB , and the calculation time is only about 60 % of the traditional wavelet transform .
【作者單位】: 華北電力大學(xué)電子與通信工程系;
【基金】:國家自然科學(xué)基金項(xiàng)目(61377088) 河北省自然科學(xué)基金項(xiàng)目(F2014502098)
【分類號(hào)】:TN25;TN911.7
【相似文獻(xiàn)】
相關(guān)期刊論文 前5條
1 劉戰(zhàn)存;嚴(yán)謹(jǐn)而精密的創(chuàng)新——瑞利進(jìn)行研究的特點(diǎn)[J];物理;2000年10期
2 蕭如珀;楊信男;;1894年8月13日:瑞利男爵和氬的發(fā)現(xiàn)——一個(gè)忠于真理的追求者,他發(fā)現(xiàn)了一個(gè)原未追求的真理[J];現(xiàn)代物理知識(shí);2014年04期
3 楊慶余,周榮生;瑞利勛爵對現(xiàn)代聲學(xué)基礎(chǔ)理論的開創(chuàng)性貢獻(xiàn)[J];徐州師范大學(xué)學(xué)報(bào)(自然科學(xué)版);2001年03期
4 陳福連,史祖齡,鐘英杰;關(guān)于瑞利激振準(zhǔn)則的討論[J];浙江工學(xué)院學(xué)報(bào);1994年03期
5 廖劍暉;賀寅彪;;瑞利法在耦合系統(tǒng)振動(dòng)固有頻率計(jì)算中的應(yīng)用[J];機(jī)械工程師;2014年07期
,本文編號(hào):2084819
本文鏈接:http://sikaile.net/kejilunwen/xinxigongchenglunwen/2084819.html
最近更新
教材專著