某水電機(jī)組異常水力振動分析與處理
發(fā)布時間:2018-09-13 09:43
【摘要】:某水電機(jī)組在運(yùn)行時,發(fā)現(xiàn)壓力脈動、機(jī)組振動與噪聲較往常明顯增大,且隨負(fù)荷的增加而增大,這將嚴(yán)重威脅機(jī)組的安全穩(wěn)定運(yùn)行。為此進(jìn)行了變負(fù)荷試驗(yàn),對變負(fù)荷數(shù)據(jù)進(jìn)行分析,發(fā)現(xiàn)活動導(dǎo)葉過流不均是引起機(jī)組振動過大的原因,停機(jī)檢查發(fā)現(xiàn)活動導(dǎo)葉處卡有異物,取出異物后,機(jī)組壓力脈動與振動過大問題得到解決,為類似問題的處理提供了參考依據(jù)。
[Abstract]:When a hydroelectric unit is in operation, it is found that the pressure pulsation, the vibration and noise of the unit are obviously increased than usual, and increase with the increase of load, which will seriously threaten the safe and stable operation of the unit. For this reason, the variable load test was carried out, and the variable load data were analyzed. It was found that the uneven flow of the moving guide vane was the cause of the excessive vibration of the unit. The problems of pressure pulsation and excessive vibration are solved, which provides a reference for the treatment of similar problems.
【作者單位】: 國網(wǎng)新源控股有限公司技術(shù)中心;
【分類號】:TV738
[Abstract]:When a hydroelectric unit is in operation, it is found that the pressure pulsation, the vibration and noise of the unit are obviously increased than usual, and increase with the increase of load, which will seriously threaten the safe and stable operation of the unit. For this reason, the variable load test was carried out, and the variable load data were analyzed. It was found that the uneven flow of the moving guide vane was the cause of the excessive vibration of the unit. The problems of pressure pulsation and excessive vibration are solved, which provides a reference for the treatment of similar problems.
【作者單位】: 國網(wǎng)新源控股有限公司技術(shù)中心;
【分類號】:TV738
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 ;我國自主研制世界最大水電機(jī)組[J];水電廠自動化;2008年02期
2 ;引進(jìn)水電機(jī)組技術(shù)研討會在富春江召開[J];水力發(fā)電;1994年11期
3 ;“700MW級巨型水電機(jī)組研制”被授予四川省重大科技成果轉(zhuǎn)化示范項目[J];東方電氣評論;2013年04期
4 沈磊;采用指標(biāo)控制法監(jiān)測水電機(jī)組的穩(wěn)定運(yùn)行[J];東北電力技術(shù);2000年05期
5 李連貴;水電機(jī)組用新型制動器開發(fā)成功[J];發(fā)電設(shè)備;2001年05期
6 周波;改善水電機(jī)組運(yùn)行穩(wěn)定性[J];電器工業(yè);2004年05期
7 施炳利;小型水電機(jī)組取消永磁機(jī)出現(xiàn)的問題及解決方法[J];河北水利;2004年08期
8 瞿f,
本文編號:2240803
本文鏈接:http://sikaile.net/kejilunwen/shuiwenshuili/2240803.html