本文選題:高拱壩 + 中期降溫階段; 參考:《水電能源科學(xué)》2017年03期
【摘要】:為準(zhǔn)確了解某高拱壩壩段混凝土中期通水冷卻降溫影響因素的敏感性及其最優(yōu)溫控措施,采用有限元仿真分析方法,定性定量分析了中期降溫階段冷卻水通水流量、通水溫度、通水時長、混凝土單層層厚對壩段混凝土日降溫速率的影響程度,發(fā)現(xiàn)通水流量及通水溫度影響最大;進(jìn)而構(gòu)建了混凝土日降溫速率與通水流量、通水溫度之間的非線性回歸方程,從定量角度給出了最優(yōu)溫控措施;這可為同類工程中期降溫階段的溫控措施提供參考依據(jù)。
[Abstract]:In order to accurately understand the sensitivity of the factors affecting the cooling and cooling of concrete in the middle stage of a high arch dam and its optimal temperature control measures, the flow rate and temperature of cooling water in the intermediate cooling stage are qualitatively and quantitatively analyzed by using the finite element simulation analysis method. The effect of the length of water flow and the thickness of concrete monolayer layer on the daily cooling rate of concrete in dam section is found to be the most important, and the daily cooling rate and flow rate of concrete are constructed. The optimal temperature control measures are given from the quantitative point of view according to the nonlinear regression equation of water temperature, which can provide a reference for the temperature control measures in the intermediate cooling stage of similar projects.
【作者單位】: 三峽大學(xué)水利與環(huán)境學(xué)院;三峽大學(xué)湖北省水電工程施工與管理重點(diǎn)實(shí)驗(yàn)室;
【基金】:國家自然科學(xué)基金項(xiàng)目(51479103) 三峽大學(xué)研究生科研創(chuàng)新基金項(xiàng)目(SDYC2015016)
【分類號】:TV544
【參考文獻(xiàn)】
相關(guān)期刊論文 前7條
1 朱伯芳;;小灣拱壩施工期裂縫成因的再探討[J];水利水電技術(shù);2015年04期
2 錢波;宋銘明;;某碾壓混凝土重力壩溫控方案優(yōu)化研究[J];長江科學(xué)院院報;2013年10期
3 朱伯芳;;論混凝土壩的水管冷卻[J];水利學(xué)報;2010年05期
4 王振紅;張國新;于書萍;劉有志;;水工薄壁混凝土結(jié)構(gòu)溫控參數(shù)的敏感性分析[J];武漢理工大學(xué)學(xué)報(交通科學(xué)與工程版);2010年02期
5 楊萍;朱伯芳;劉毅;劉玉;白迎;;混凝土拱壩溫控措施仿真敏感性分析[J];水力發(fā)電;2009年08期
6 賀金仁;周永健;;混凝土水管冷卻效果敏感性分析[J];水電能源科學(xué);2009年03期