擠壓套管鋼筋冷連接節(jié)點(diǎn)力學(xué)性能試驗(yàn)
發(fā)布時間:2018-03-23 03:12
本文選題:四面六邊透水框架 切入點(diǎn):冷連接 出處:《人民黃河》2017年01期 論文類型:期刊論文
【摘要】:擠壓冷連接試驗(yàn)是針對四面六邊透水框架節(jié)點(diǎn)力學(xué)性能而進(jìn)行的試驗(yàn)研究。通過萬能試驗(yàn)機(jī)的抗拉試驗(yàn)對比傳統(tǒng)的焊接抗拉強(qiáng)度,試驗(yàn)設(shè)計(jì)套管材料、千斤頂尖角角度、壓痕長度、千斤頂輸出壓力和鋼筋表面光滑程度5種因素,探索不同因素對套管擠壓鋼筋冷連接節(jié)點(diǎn)抗拉強(qiáng)度的影響,并找到最優(yōu)組合。通過對試驗(yàn)數(shù)據(jù)分析得出,在無縫鋼管材料、千斤頂尖角角度為43°、壓痕長度為4 cm、壓力為50 MPa和帶肋鋼筋為最優(yōu)組合。
[Abstract]:The extrusion cold connection test is an experimental study aimed at the mechanical properties of the joints of the four-sided and six-sided water-permeable frame. The tensile strength of the universal testing machine is compared with that of the traditional welding tensile strength, the casing material is designed and the angle of the Jack is pointed out. Five factors, such as indentation length, Jack output pressure and surface smoothness of steel bar, are discussed. The influence of different factors on tensile strength of cold connection joint of casing extruded steel bar is explored, and the optimum combination is found. In seamless steel tube, the angle of Jack is 43 擄, the indentation length is 4 cm, the pressure is 50 MPa and the ribbed steel bar is the optimal combination.
【作者單位】: 重慶交通大學(xué)水利水運(yùn)工程教育部重點(diǎn)實(shí)驗(yàn)室暨國家內(nèi)河航道整治工程技術(shù)研究中心;河海大學(xué)巖土力學(xué)與堤壩工程教育部重點(diǎn)實(shí)驗(yàn)室;長江重慶航道工程局;
【基金】:國家自然科學(xué)基金資助項(xiàng)目(51349007) 重慶市教委科學(xué)技術(shù)研究項(xiàng)目(KJ130412) 重慶市基礎(chǔ)與前沿研究計(jì)劃項(xiàng)目(cstc2013jcyj A30006)
【分類號】:TV33
【參考文獻(xiàn)】
相關(guān)期刊論文 前6條
1 孫艷;李俊杰;;剪力墻豎向鋼筋冷鐓粗直螺紋套筒連接的應(yīng)用[J];建材世界;2013年05期
2 房世龍;楊國巍;;四面體透水框架群防沖固腳技術(shù)研究進(jìn)展[J];水利科技與經(jīng)濟(jì);2009年12期
3 萬觀水;;粗直徑鋼筋冷擠壓套筒連接技術(shù)[J];廣東建材;2006年07期
4 陳強(qiáng);莊清金;;帶肋鋼筋套筒冷擠壓連接技術(shù)的應(yīng)用[J];中國市政工程;2006年01期
5 肖巖,郭玉榮,何文輝,吳徽;局部加勁鋼套管加固鋼筋混凝土柱的研究[J];建筑結(jié)構(gòu)學(xué)報;2003年06期
6 郁z,