滲透排放一體化雨水管道系統(tǒng)在雨水調(diào)蓄工程中的應(yīng)用
發(fā)布時間:2019-05-29 05:52
【摘要】:就北京市《雨水控制與利用工程設(shè)計規(guī)范》(DB 11/685-2013)中雨水入滲設(shè)施的滲透排放一體化設(shè)施的設(shè)置條件、實施方案、滲透管(井)秒滲透量計算、儲水量計算等設(shè)計參數(shù)的確定進行了分析,為滲排一體化設(shè)施的實際滲透效果評估和有效儲水量計算提供了參考和思路。
[Abstract]:According to the setting conditions, implementation scheme and second permeability calculation of Rain Water infiltration facilities in Beijing Rain Water Code for Control and Utilization Engineering Design (DB 11 / 685 / 2013), The determination of design parameters such as water storage calculation is analyzed, which provides a reference and train of thought for the evaluation of actual seepage effect and the calculation of effective water storage in the integrated facilities of seepage and drainage.
【作者單位】: 北京泰寧科創(chuàng)雨水利用技術(shù)股份有限公司;
【分類號】:TV213.9;TU992
,
本文編號:2487704
[Abstract]:According to the setting conditions, implementation scheme and second permeability calculation of Rain Water infiltration facilities in Beijing Rain Water Code for Control and Utilization Engineering Design (DB 11 / 685 / 2013), The determination of design parameters such as water storage calculation is analyzed, which provides a reference and train of thought for the evaluation of actual seepage effect and the calculation of effective water storage in the integrated facilities of seepage and drainage.
【作者單位】: 北京泰寧科創(chuàng)雨水利用技術(shù)股份有限公司;
【分類號】:TV213.9;TU992
,
本文編號:2487704
本文鏈接:http://sikaile.net/kejilunwen/sgjslw/2487704.html