預(yù)制混凝土框架柱及節(jié)點(diǎn)抗震性能試驗(yàn)研究
[Abstract]:Construction of energy-saving, land-saving and environmental-friendly housing has become the goal and direction of housing construction in China. Through research and exploration, Harbin University of Technology has independently developed and developed the lapped connection of restrained grouting anchor bars, which solves the connection problem of prefabricated members in concrete structures, and combines with the actual situation in the field of housing in China. In this paper, a precast concrete connection method suitable for our country is put forward, which is called "lapping connection of restrained grouting anchor steel bar". A series of tests are carried out in view of this connection mode. And formed a prefabricated concrete shear wall structure system with independent intellectual property rights. In this paper, the method of lapping connection of restrained grouting anchor steel bar is taken as the starting point, and a variety of construction methods suitable for concrete frame member connection are put forward, and the seismic behavior tests of longitudinal reinforcement connection of frame column and Liang Zhu connection at frame joint are carried out. The pseudostatic tests of 9 full-scale frame columns were completed, including 6 prefabricated columns and 3 cast-in-situ contrast columns. The mechanical behavior, failure form, hysteretic curve, skeleton curve and stiffness degradation of each specimen under horizontal reciprocating load are analyzed. The failure mode of the two prefabricated frame columns with restrained grouting anchor insertion technique is the same as that of cast-in-place columns, and the bearing capacity is close, but the ductility is better than that of the contrast parts. On the other hand, by observing the whole deformation curve and comparing the energy dissipation indexes, the prefabricated frame columns have the same bearing capacity seismic performance and better energy dissipation performance as cast-in-place columns. Three different kinds of precast concrete frame joints were first proposed, and the quasi-static tests of three full-scale concrete frame joints and one cast-in-place joint were carried out. The crack development process of three prefabricated frame joints under reciprocating load is obtained by experiments, and the hysteretic curves of the specimens under three kinds of assembly modes are obtained by comparing with the macroscopic phenomena shown by the forces acting on the contrasts. The degradation of skeleton curve and stiffness, and the evaluation index and ductility index of joint energy dissipation ability are obtained through the analysis of test data, and the seismic performance of precast concrete frame joints is evaluated synthetically. By comparing the bearing capacity and various indexes of the obtained joints, it is found that the connection mode of the prefabricated joints is basically similar to that of the cast-in-place joints, and the overall performance of the prefabricated joints is good. Finally, the experimental results of frame column and frame joint are compared after normalization.
【學(xué)位授予單位】:哈爾濱工業(yè)大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2013
【分類(lèi)號(hào)】:TU375.4
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 謝其盛;高軍;;淺談鋼結(jié)構(gòu)住宅的抗震性能[J];住宅產(chǎn)業(yè);2008年06期
2 魏春明;宋玉普;劉健;;現(xiàn)澆鋼筋混凝土框架柱施工縫抗震性能試驗(yàn)研究[J];大連理工大學(xué)學(xué)報(bào);2006年04期
3 沈章春;王全鳳;沈劍波;劉江;;改善短柱抗震性能的若干措施[J];建筑技術(shù);2007年05期
4 康忠榮;;規(guī)范中抗震柱軸壓比限值問(wèn)題的探討[J];江西建材;2009年02期
5 汪梅;梁書(shū)亭;李刻銘;;新型全裝配式干式連接框架柱的試驗(yàn)研究[J];建筑技術(shù);2010年01期
6 武江傳;;混凝土預(yù)制裝配框架結(jié)構(gòu)梁柱柔性連接初探[J];安徽建筑;2011年04期
7 趙世春;;空腹桁架式型鋼混凝土框架柱抗震性能的試驗(yàn)[J];工業(yè)建筑;2007年02期
8 白國(guó)良;劉超;趙洪金;姚菲;朱麗華;;再生混凝土框架柱抗震性能試驗(yàn)研究[J];地震工程與工程振動(dòng);2011年01期
9 孫巧珍;劉暢;翟彬;;高強(qiáng)材料置換截面加固混凝土框架柱的抗震性能試驗(yàn)研究[J];建筑科學(xué);2011年01期
10 陳麗艷;;淺談建筑工程中框架結(jié)構(gòu)構(gòu)造與設(shè)計(jì)[J];價(jià)值工程;2011年05期
相關(guān)會(huì)議論文 前10條
1 王明鈺;;反復(fù)荷載作用下鋼筋輕骨料混凝土框架柱的抗震性能試驗(yàn)研究[A];中國(guó)地震學(xué)會(huì)第八次學(xué)術(shù)大會(huì)論文摘要集[C];2000年
2 李俊華;薛建陽(yáng);趙鴻鐵;;型鋼高強(qiáng)混凝土框架柱抗震性能的神經(jīng)網(wǎng)絡(luò)評(píng)估[A];中國(guó)鋼協(xié)鋼-混凝土組合結(jié)構(gòu)分會(huì)第九次年會(huì)論文集[C];2003年
3 何廣杰;張瑞云;;異形柱的工程設(shè)計(jì)探討[A];第七屆全國(guó)結(jié)構(gòu)工程學(xué)術(shù)會(huì)議論文集(第Ⅱ卷)[C];1998年
4 何和萍;;拱式轉(zhuǎn)換層剛度比對(duì)結(jié)構(gòu)抗震性能的影響分析[A];第18屆全國(guó)結(jié)構(gòu)工程學(xué)術(shù)會(huì)議論文集第Ⅱ冊(cè)[C];2009年
5 孫愛(ài)伏;唐柏鑒;;鋼框架結(jié)構(gòu)體系的抗震性能對(duì)比[A];第六屆全國(guó)現(xiàn)代結(jié)構(gòu)工程學(xué)術(shù)研討會(huì)論文集[C];2006年
6 張艷霞;;有關(guān)框架-剪力墻(支撐)體系內(nèi)力近似計(jì)算問(wèn)題的探討[A];第14屆全國(guó)結(jié)構(gòu)工程學(xué)術(shù)會(huì)議論文集(第一冊(cè))[C];2005年
7 王俊雄;肖冬莉;;高強(qiáng)砼在重慶某三個(gè)工程中的應(yīng)用[A];高強(qiáng)混凝土及其應(yīng)用第二屆學(xué)術(shù)討論會(huì)論文集[C];1995年
8 邊凱;康谷貽;;鋼筋砼框架柱受剪性能研究[A];第三屆全國(guó)結(jié)構(gòu)工程學(xué)術(shù)會(huì)議論文集(上)[C];1994年
9 劉陽(yáng);郭子雄;楊勇;;不同結(jié)構(gòu)震害指數(shù)計(jì)算模型的比較研究[A];防震減災(zāi)工程研究與進(jìn)展——全國(guó)首屆防震減災(zāi)工程學(xué)術(shù)研討會(huì)論文集[C];2004年
10 王文達(dá);韓林海;;鋼管混凝土框架簡(jiǎn)化二階分析方法探討[A];中國(guó)鋼協(xié)鋼-混凝土組合結(jié)構(gòu)分會(huì)第十一次年會(huì)論文集[C];2007年
相關(guān)重要報(bào)紙文章 前10條
1 孫永權(quán) 陳如榮 浙江紹興 馮世忠;高層建筑抗震設(shè)計(jì)短柱問(wèn)題的處理[N];建筑時(shí)報(bào);2007年
2 楊守勇;新農(nóng)村規(guī)劃建設(shè)需注意房屋抗震性能[N];東方城鄉(xiāng)報(bào);2008年
3 錢(qián)錚;日本 建筑定期做“體檢”[N];人民日?qǐng)?bào);2008年
4 陳進(jìn)周;抗震型管材漸受業(yè)內(nèi)關(guān)注[N];中國(guó)建設(shè)報(bào);2008年
5 揚(yáng)帆;震災(zāi)悄悄影響市民生活[N];無(wú)錫日?qǐng)?bào);2008年
6 甄書(shū)秀;房子如何防震備受關(guān)注[N];中國(guó)質(zhì)量報(bào);2008年
7 陳熹熹邋汪曉霞;住宅抗震性能成關(guān)注熱點(diǎn) 抗震能力可否要寫(xiě)進(jìn)合同[N];經(jīng)理日?qǐng)?bào);2008年
8 林佳;我省全面篩查建筑抗震性能[N];福建工商時(shí)報(bào);2008年
9 瞿學(xué)江;抗震系數(shù)考驗(yàn)震蕩樓市[N];寧夏日?qǐng)?bào);2008年
10 五合國(guó)際(5+1 Werkhart)結(jié)構(gòu)工程師 劉平;從震害談房屋建筑的抗震性能(下)[N];中華建筑報(bào);2008年
相關(guān)博士學(xué)位論文 前10條
1 張國(guó)軍;大型火力發(fā)電廠高強(qiáng)混凝土框架柱的抗震性能研究[D];西安建筑科技大學(xué);2003年
2 黃選明;帶暗支撐短肢剪力墻及筒體結(jié)構(gòu)抗震性能試驗(yàn)及理論研究[D];北京工業(yè)大學(xué);2005年
3 高慧婷;Fe/Zn復(fù)合材料及液壓阻尼器抗震性能數(shù)值仿真研究[D];吉林大學(xué);2004年
4 王曉鋒;配置高強(qiáng)鋼筋混凝土框架柱抗震性能研究[D];中國(guó)建筑科學(xué)研究院;2013年
5 馮宏;型鋼高強(qiáng)混凝土框架柱抗震性能研究[D];重慶大學(xué);2013年
6 施剛;鋼框架半剛性端板連接的靜力和抗震性能研究[D];清華大學(xué);2005年
7 劉肖凡;箱形轉(zhuǎn)換層上短肢剪力墻結(jié)構(gòu)體系抗震性能研究[D];武漢理工大學(xué);2008年
8 夏訓(xùn)成;火電廠有粘結(jié)預(yù)應(yīng)力混凝土框架抗震性能試驗(yàn)研究[D];武漢理工大學(xué);2009年
9 劉繼明;鋼筋混凝土復(fù)合受力構(gòu)件受扭行為和設(shè)計(jì)方法的研究[D];西安建筑科技大學(xué);2004年
10 張昊宇;協(xié)同式套建增層預(yù)應(yīng)力混凝土框架抗震性能與設(shè)計(jì)方法[D];哈爾濱工業(yè)大學(xué);2009年
相關(guān)碩士學(xué)位論文 前10條
1 李世達(dá);預(yù)制混凝土框架柱及節(jié)點(diǎn)抗震性能試驗(yàn)研究[D];哈爾濱工業(yè)大學(xué);2013年
2 丁小艷;L形截面寬肢柱低周反復(fù)荷載受剪性能試驗(yàn)研究[D];天津大學(xué);2007年
3 張林振;預(yù)制預(yù)應(yīng)力混凝土框架結(jié)構(gòu)抗震設(shè)計(jì)有關(guān)問(wèn)題研究[D];東南大學(xué);2006年
4 陳遠(yuǎn)峰;考慮施工縫影響的框架結(jié)構(gòu)抗震性能試驗(yàn)研究[D];南京工業(yè)大學(xué);2005年
5 王莉;新型外包鋼—混凝土組合框架的非線性分析[D];江蘇大學(xué);2007年
6 朱浪濤;大跨度預(yù)應(yīng)力混凝土梁式轉(zhuǎn)換結(jié)構(gòu)受力性能分析研究[D];重慶大學(xué);2009年
7 蔣凡;框支—短肢剪力墻結(jié)構(gòu)中斜柱轉(zhuǎn)換結(jié)構(gòu)的抗震試驗(yàn)研究[D];重慶大學(xué);2005年
8 張高峰;免拆模保溫混凝土承重墻體系墻片單元的抗震性能試驗(yàn)研究[D];北京工業(yè)大學(xué);2003年
9 石學(xué)糧;鋼絲網(wǎng)墻片單元組合墻體的抗震性能試驗(yàn)研究[D];北京工業(yè)大學(xué);2004年
10 常廣勛;長(zhǎng)肢—字形截面柱抗震性能試驗(yàn)研究及理論分析[D];北京工業(yè)大學(xué);2005年
本文編號(hào):2295794
本文鏈接:http://sikaile.net/kejilunwen/sgjslw/2295794.html