基于ARM的動(dòng)力與環(huán)境系統(tǒng)集中采集單元的設(shè)計(jì)與實(shí)現(xiàn)
[Abstract]:Data center room power (distribution cabinet, power cabinet, UPS, generators, batteries, etc.), environment (air conditioning, leak detection, temperature and humidity), fire (smoke detection), security (infrared detection, Access Control and other equipment for the data center computer equipment to provide a reliable operation of the guarantee. Therefore, in order to ensure the safe and reliable work of computer equipment, it is extremely necessary to monitor and manage the power, environment and other equipment in the computer room. By analyzing and classifying the power and environment equipments in the computer room of the data center, a centralized collection unit is designed to monitor and control the equipment in the computer room in real time. The hardware circuit design of the centralized acquisition unit is based on the i.MX287 processor of NXP Company, and designs the power supply circuit, dual Ethernet interface circuit, intelligent device interface circuit, data acquisition circuit, external storage circuit, etc. USB bus extended interface circuit and other circuit modules. The software of the centralized acquisition unit is designed and developed based on the Ubuntu 14.04 LTS operating system. Firstly, the kernel of Uboot and Linux 2.6.35 is transplanted, and the file system is configured, and the application program is compiled and downloaded to the hardware platform of the centralized acquisition unit. Complete system integration. In addition, the basic centralized monitoring software is designed to realize the centralized monitoring of the equipment in the data center computer room and the system integration debugging of the designed centralized acquisition unit. The design and development of the centralized acquisition unit can realize the real-time monitoring and control of the power and environmental equipment in the computer room, reduce the cost of human operation and maintenance, and reduce the cost of maintenance.
【學(xué)位授予單位】:蘭州理工大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2017
【分類號(hào)】:TP308
【參考文獻(xiàn)】
相關(guān)期刊論文 前5條
1 陳海軍;;論通信基站動(dòng)力環(huán)境監(jiān)控系統(tǒng)的設(shè)計(jì)和開發(fā)[J];中國管理信息化;2015年20期
2 王琪;;通信機(jī)房動(dòng)環(huán)監(jiān)控系統(tǒng)研究與設(shè)計(jì)[J];電源世界;2013年06期
3 高健;;動(dòng)力環(huán)境集中監(jiān)控系統(tǒng)的應(yīng)用和發(fā)展[J];電信工程技術(shù)與標(biāo)準(zhǔn)化;2006年06期
4 雷遠(yuǎn)揚(yáng);通信電源設(shè)備、空調(diào)和環(huán)境集中監(jiān)控管理系統(tǒng)[J];電信工程技術(shù)與標(biāo)準(zhǔn)化;2003年12期
5 王艷文,宗凌;動(dòng)力環(huán)境集中監(jiān)控系統(tǒng)的現(xiàn)狀與演化[J];電信科學(xué);1998年08期
相關(guān)碩士學(xué)位論文 前6條
1 孫志文;數(shù)據(jù)中心動(dòng)力環(huán)境監(jiān)控系統(tǒng)的研究與設(shè)計(jì)[D];燕山大學(xué);2014年
2 鄭莎莎;基于TCP/IP的動(dòng)力與環(huán)境監(jiān)控系統(tǒng)數(shù)據(jù)傳輸研究[D];山東大學(xué);2012年
3 陸崢;通信機(jī)房動(dòng)力環(huán)境集中監(jiān)控系統(tǒng)研究[D];北京郵電大學(xué);2012年
4 丁晏飛;通信動(dòng)力與環(huán)境集中監(jiān)控系統(tǒng)的研究與應(yīng)用[D];武漢科技大學(xué);2008年
5 殷培紅;動(dòng)力及環(huán)境集中監(jiān)控系統(tǒng)的研究應(yīng)用[D];華北電力大學(xué)(北京);2007年
6 殷鵬;通信機(jī)房動(dòng)力與環(huán)境監(jiān)控系統(tǒng)實(shí)現(xiàn)和研究[D];南京理工大學(xué);2002年
,本文編號(hào):2398860
本文鏈接:http://sikaile.net/kejilunwen/jisuanjikexuelunwen/2398860.html