  本文選題:循環(huán)冷卻水系統(tǒng) + 水質(zhì)檢測 ; 參考:《浙江工業(yè)大學(xué)》2017年碩士論文


【摘要】:循環(huán)冷卻水水質(zhì)硬化會導(dǎo)致冷卻系統(tǒng)的結(jié)垢堵塞,引起設(shè)備損壞,造成重大經(jīng)濟(jì)損失。循環(huán)水中的電導(dǎo)率、pH值等參數(shù)直接影響著循環(huán)系統(tǒng)的結(jié)垢的速度。同時它們也是評價系統(tǒng)水資源的節(jié)能性、環(huán)保性的重要指標(biāo)。無論從保證循環(huán)冷卻水系統(tǒng)的穩(wěn)定運行角度,還是節(jié)約國家稀缺的水資源角度,高精度的、自動化的水質(zhì)檢測儀都十分具有研究價值。針對如何提升水質(zhì)檢測儀精度和穩(wěn)定性的問題,開發(fā)了CORTEX-M3為核心的循環(huán)水水質(zhì)檢測裝置。探索了比較測量法和Kalman濾波在檢測儀器上的應(yīng)用,來消除系統(tǒng)誤差,提高檢測的精度和穩(wěn)定性。論文主要工作和成果如下:(1)通過對水質(zhì)檢測在國內(nèi)外研究現(xiàn)狀,結(jié)合水質(zhì)檢測儀器的發(fā)展、企業(yè)實際需求和國家標(biāo)準(zhǔn),確立了循環(huán)冷卻水水質(zhì)參數(shù)檢測的方案。(2)針對主要檢測參數(shù)電導(dǎo)率和pH值,從它們的傳感器結(jié)構(gòu)和檢測原理出發(fā),詳細(xì)地分析了電導(dǎo)率和p H等參數(shù)在檢測過程中的影響因素,并提出了解決方法。(3)針對檢測電路中的主要誤差的分析,首次引入比較測量法和Kalman濾波方法應(yīng)用于水質(zhì)檢測,提高了檢測精度。(4)根據(jù)循環(huán)冷卻水水質(zhì)參數(shù)檢測的方案,完成了循環(huán)冷卻水水質(zhì)檢測的硬件裝置設(shè)計,并對提高檢測參數(shù)精度的電路設(shè)計方法展開了研究。為了儀器能夠全面的實現(xiàn)功能,進(jìn)一步完成系統(tǒng)初始化、采集計算、自恢復(fù)、通信等軟件程序。(5)進(jìn)行了檢測裝置的精度和重復(fù)性實驗,驗證了儀器的精度、穩(wěn)定性和可靠性。通過與XR-620 CTD+水質(zhì)儀器和PHS-25型號pH檢測儀器的對比分析,證明了基于比較測量法和卡爾曼濾波處理方法的循環(huán)冷卻水水質(zhì)監(jiān)測裝置是行之有效的。論文開發(fā)的水質(zhì)檢測儀,能夠?qū)崿F(xiàn)在循環(huán)冷卻水系統(tǒng)上的自動化、高精度和穩(wěn)定的檢測目標(biāo)。同時首次探索了比較測量法和卡爾曼濾波在水質(zhì)檢測儀器的應(yīng)用,并且得到了較好的實驗結(jié)果。對水質(zhì)檢測儀的研究,不僅為循環(huán)冷卻水的結(jié)垢和節(jié)水提供了數(shù)據(jù)參考,也為阻垢控制奠定了基礎(chǔ)。
[Abstract]:The water quality hardening of circulating cooling water will cause the scaling and blockage of the cooling system and cause the damage of the equipment, causing major economic losses. The conductivity of the circulating water and the pH value directly affect the speed of the scaling in the circulating system. At the same time, they are also important indicators for evaluating the energy saving and environmental protection of the water resources of the system. In order to improve the precision and stability of water quality detector, a circulating water quality testing device with CORTEX-M3 as the core is developed for the problem of improving the precision and stability of the water quality detector. The comparative measurement method and the Kalman filter are explored. The main work and achievements of the paper are as follows: (1) through the research status of water quality testing at home and abroad, combining the development of water quality testing instruments, the actual demand of enterprises and the national standard, the water quality parameters detection scheme of circulating cooling water is established. (2) The main detection parameters of electrical conductivity and pH value, from their sensor structure and detection principle, detailed analysis of the conductivity and P H parameters in the detection process, and put forward solutions. (3) for the analysis of the main error in the detection circuit, the first introduction of comparative measurement and Kalman filtering method for water quality is applied to the water quality for the first time. The detection accuracy is improved. (4) the hardware design of the circulating cooling water quality detection is completed according to the scheme of the water quality parameters detection of circulating cooling water, and the circuit design method for improving the precision of the detection parameters is studied. In order to realize the full function of the instrument, the system initializes, collect and calculate, and recover. A software program such as communication. (5) the accuracy and repeatability of the testing device are carried out, and the accuracy, stability and reliability of the instrument are verified. By comparing with the XR-620 CTD+ water quality instrument and the PHS-25 type pH detection instrument, the water quality monitoring device of the circulating cooling water based on the comparative measurement method and the Calman filter processing method is proved. The water quality tester developed in this paper can realize the automatic, high precision and stable detection target on the circulating cooling water system. At the same time, the application of the comparative measurement method and Calman filter in the water quality detection instrument is first explored, and the better experimental results are obtained. The research on the water quality detector is not only a cycle of circulation. It provides data reference for scaling and water saving of cooling water, and lays a foundation for scale control.
【學(xué)位授予單位】:浙江工業(yè)大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2017
【分類號】:TQ085.1

【參考文獻(xiàn)】

相關(guān)期刊論文 前10條

1 鄔秋玲;;淺析溶液酸堿度的計算[J];考試周刊;2016年A2期

2 邢庭煒;;RS232串口通信在PC機與單片機通信中的應(yīng)用[J];信息系統(tǒng)工程;2016年08期

3 王小龍;楊元慧;吳春富;;基于STM32的服務(wù)機器人嵌入式安全監(jiān)控系統(tǒng)設(shè)計[J];龍巖學(xué)院學(xué)報;2016年02期

4 危蓉;徐偉;麥永浩;;ARM模擬器的設(shè)計與實現(xiàn)[J];海軍工程大學(xué)學(xué)報;2016年02期

5 李芹;王偉;彭道剛;;過程控制測量信號數(shù)字濾波方法優(yōu)化[J];實驗室研究與探索;2016年04期

6 趙杰;張靜;;pH計和電導(dǎo)率儀的水分析解決方案分析[J];電子世界;2016年01期

7 楊爽;費騰;欒德福;;基于ICL8038的交流恒流源設(shè)計[J];陜西電力;2016年01期

8 黃學(xué)達(dá);翁明江;;LTE-A手機看門狗電路的設(shè)計與研究[J];電子器件;2015年06期

9 商書芹;譚璐;曹龍智;;淺談水質(zhì)檢測數(shù)據(jù)的合理性分析[J];科技展望;2015年21期

10 張國城;;對電導(dǎo)率儀溫度系數(shù)示值誤差的新認(rèn)識[J];中國計量;2015年11期

相關(guān)碩士學(xué)位論文 前10條

1 孫銘蔚;基于ARM的車位實時監(jiān)測系統(tǒng)的設(shè)計[D];黑龍江大學(xué);2016年

2 朱峰;基于ARM的儀器系統(tǒng)軟件設(shè)計與開發(fā)[D];電子科技大學(xué);2016年

3 余翔;新型電導(dǎo)率和pH水質(zhì)參數(shù)檢測技術(shù)與實驗研究[D];浙江大學(xué);2015年

4 韓孝貞;多參數(shù)水質(zhì)檢測儀控制與數(shù)據(jù)處理軟件系統(tǒng)設(shè)計[D];重慶大學(xué);2014年

5 張敏;脈沖電源模塊中測控單元PCB的電磁兼容性研究[D];南京理工大學(xué);2013年

6 謝潔意;高精度模擬測量電路精度增長方法的研究[D];浙江大學(xué);2012年

7 劉君華;電磁兼容現(xiàn)場測試中的干擾源辨識技術(shù)研究[D];西安電子科技大學(xué);2012年

8 王海波;海水淡化用pH及電導(dǎo)率在線檢測系統(tǒng)研究[D];杭州電子科技大學(xué);2011年

9 高山川;雙頻正弦信號電導(dǎo)率測量儀設(shè)計[D];大連理工大學(xué);2010年

10 蘇瑞東;基于電渦流法的電解質(zhì)溶液電導(dǎo)率測量系統(tǒng)研制[D];浙江大學(xué);2010年



本文編號:1983581

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/kejilunwen/huagong/1983581.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶67d92***提供,本站僅收錄摘要或目錄,作者需要刪除請E-mail郵箱bigeng88@qq.com