快響應(yīng)門控光電倍增管設(shè)計(jì)
發(fā)布時(shí)間:2019-07-05 16:58
【摘要】:門響應(yīng)時(shí)間和消光比是門控光電倍增管的兩個(gè)重要性能參數(shù)。介紹了將俄制CHφT5型光電倍增管改制為門控光電倍增管的設(shè)計(jì)。采用控制光電倍增管第二聚焦極的方法,設(shè)計(jì)快響應(yīng)門控制電路,使門控光電倍增管具有3個(gè)量級(jí)以上的消光比,開門延遲響應(yīng)時(shí)間為70 ns,光電倍增管恢復(fù)輸出的時(shí)間為20 ns。光電倍增管靈敏度降低了20%。
[Abstract]:Gate response time and extinction ratio are two important performance parameters of gated photomultiplier tube. This paper introduces the design of changing the Russian CH蠁 T 5 photomultiplier tube into a gated photomultiplier tube. A fast response gate control circuit is designed by controlling the second focusing pole of the photomultiplier tube. The gate photomultiplier tube has a extinction ratio of more than three orders of magnitude, and the delay response time of the door is 70 ns,. The recovery time of the photomultiplier tube is 20 ns.. The sensitivity of photomultiplier tube is reduced by 20%.
【作者單位】: 中國工程物理研究院核物理與化學(xué)研究所;
【分類號(hào)】:TN152
本文編號(hào):2510677
[Abstract]:Gate response time and extinction ratio are two important performance parameters of gated photomultiplier tube. This paper introduces the design of changing the Russian CH蠁 T 5 photomultiplier tube into a gated photomultiplier tube. A fast response gate control circuit is designed by controlling the second focusing pole of the photomultiplier tube. The gate photomultiplier tube has a extinction ratio of more than three orders of magnitude, and the delay response time of the door is 70 ns,. The recovery time of the photomultiplier tube is 20 ns.. The sensitivity of photomultiplier tube is reduced by 20%.
【作者單位】: 中國工程物理研究院核物理與化學(xué)研究所;
【分類號(hào)】:TN152
【相似文獻(xiàn)】
相關(guān)碩士學(xué)位論文 前1條
1 宋燦孔;多級(jí)門控時(shí)鐘網(wǎng)絡(luò)設(shè)計(jì)優(yōu)化[D];國防科學(xué)技術(shù)大學(xué);2015年
,本文編號(hào):2510677
本文鏈接:http://sikaile.net/kejilunwen/dianzigongchenglunwen/2510677.html
最近更新
教材專著