交流系統(tǒng)對直流輸電系統(tǒng)運行的影響相關問題研究
[Abstract]:With the continuous development of power grid, a very complex AC / DC hybrid system has been gradually formed in our country. The interaction of AC and DC system has become one of the key points of attention in the safe and stable operation of power grid. The voltage drop of converter bus and zero-crossing shift of commutation voltage caused by AC system fault may lead to converter turn-off angle too small and commutation failure, and continuous commutation failure will lead to DC locking, which will seriously affect the stable operation of the system. It is necessary to study an effective and accurate method for judging the failure of commutation. On the other hand, the phase-shifting trigger pulse of DC system needs to be synchronized with the system, so the trigger pulse can be adjusted according to the change of system state. However, if the frequency of the system changes, whether the abnormal trigger pulse in the process of adjustment will cause the change of the running state of the DC system, it is also necessary to carry out research. In this paper, the influence of voltage and frequency change of AC system on phase change process and phase shift trigger link of DC system is studied. The main work is as follows: (1) the basic principle of phase change process and trigger link of DC system is expounded. The influencing factors of commutation failure and the sensitivity of two trigger control links to frequency are introduced in detail, and the detailed electromagnetic transient simulation model of HVDC transmission system is established. (2) the minimum voltage drop judgment method for judging DC commutation failure is studied, and the traditional minimum voltage drop calculation method under symmetrical condition is improved. A method for calculating the minimum voltage drop considering the change of DC current and the influence of fault time is proposed. This method can also be used to calculate the probability curve of commutation failure. (3) on this basis, a minimum voltage drop calculation method under asymmetric condition is proposed. The simulation results show that the minimum voltage drop calculation method proposed in this paper has higher accuracy than the traditional method, and its effectiveness is verified. (4) the trigger principle of MACH2 in HVDC system is studied, and the influence of frequency on zero crossing point of commutation voltage is analyzed. The results show that the trigger pulse of DC system will be abnormal for a short time because of the error of judging the zero crossing point of phase-locked loop to phase-locked voltage due to the change of frequency. The fluctuation amplitude of DC system is mainly affected by the limiting link of trigger delay angle amplitude. When the rectifier side frequency increases or the inverter side frequency decreases, the operation state of DC system changes greatly.
【學位授予單位】:華中科技大學
【學位級別】:碩士
【學位授予年份】:2014
【分類號】:TM721.1
【相似文獻】
相關期刊論文 前10條
1 汪隆君;王鋼;李海鋒;李志鏗;;交流系統(tǒng)故障誘發(fā)多直流饋入系統(tǒng)換相失敗風險評估[J];電力系統(tǒng)自動化;2011年03期
2 王學之;周全;國建寶;;南方電網直流換相失敗機理及判別方法[J];南方電網技術;2013年06期
3 任震,陳永進,梁振升,黃雯瑩;高壓直流輸電系統(tǒng)換相失敗的概率分析[J];電力系統(tǒng)自動化;2004年24期
4 陳樹勇,李新年,余軍,李濤,呂鵬飛,印永華;基于正余弦分量檢測的高壓直流換相失敗預防方法[J];中國電機工程學報;2005年14期
5 靳希;郎鵬越;楊秀;;多饋入高壓直流輸電系統(tǒng)中的換相失敗淺析[J];上海電力學院學報;2006年01期
6 何朝榮;李興源;金小明;吳小辰;顏泉;;高壓直流輸電系統(tǒng)換相失敗的判斷標準[J];電網技術;2006年22期
7 何朝榮;李興源;金小明;吳小辰;顏泉;;高壓直流輸電系統(tǒng)換相失敗判斷標準的仿真分析[J];電網技術;2007年01期
8 吳沖;李興源;何朝榮;;多饋入直流交互作用因子在換相失敗研究中的應用[J];繼電器;2007年09期
9 吳沖;李興源;黃宗君;;高壓直流輸電系統(tǒng)換相失敗及其相關問題研究[J];現(xiàn)代電力;2007年03期
10 任景;李興源;金小明;吳小辰;;多饋入高壓直流輸電系統(tǒng)中逆變站濾波器投切引起的換相失敗仿真研究[J];電網技術;2008年12期
相關會議論文 前7條
1 李兆偉;賀靜波;張同尊;姜煒;方勇杰;李威;;“8.8”多回入滬直流同時換相失敗故障分析及思考[A];2013年中國電機工程學會年會論文集[C];2013年
2 梁旭懿;王鋼;李海鋒;李志鏗;;交流系統(tǒng)故障對直流換相失敗的關聯(lián)性分析[A];中國高等學校電力系統(tǒng)及其自動化專業(yè)第二十四屆學術年會論文集(上冊)[C];2008年
3 歐開健;荊勇;任震;;直流輸電系統(tǒng)換相失敗的研究——第一部分:換相失敗的影響因素分析[A];廣東省電機工程學會2003-2004年度優(yōu)秀論文集[C];2005年
4 高彩亮;黃少先;廖志偉;;基于小波奇異值和支持向量機的HVDC換相失敗故障診斷[A];中國高等學校電力系統(tǒng)及其自動化專業(yè)第二十四屆學術年會論文集(中冊)[C];2008年
5 高彬;王鋼;李海鋒;李志鏗;;一種降低HVDC系統(tǒng)換相失敗發(fā)生頻率的模糊控制器設計[A];中國高等學校電力系統(tǒng)及其自動化專業(yè)第二十四屆學術年會論文集(上冊)[C];2008年
6 孫志媛;梁小冰;孫艷;;基于EMTDC的多饋入直流輸電系統(tǒng)仿真研究[A];2006電力系統(tǒng)自動化學術交流研討大會論文集[C];2006年
7 周玲;宋曉芳;常康;李吉晨;;風電機組低電壓穿越能力對風火打捆直流外送系統(tǒng)的影響[A];2013年中國電機工程學會年會論文集[C];2013年
相關博士學位論文 前4條
1 王渝紅;交直流混合運行系統(tǒng)中的換相失敗研究[D];西南交通大學;2008年
2 陳修宇;多饋入直流系統(tǒng)電壓相互作用及其影響[D];華北電力大學;2012年
3 成敬周;高壓交直流互聯(lián)系統(tǒng)故障分析及相關保護的研究[D];浙江大學;2014年
4 曾進輝;感應濾波對多饋入直流輸電系統(tǒng)運行特性的影響研究[D];湖南大學;2013年
相關碩士學位論文 前10條
1 駱逍;特高壓直流故障特性及對受端電網繼電保護的影響研究[D];昆明理工大學;2015年
2 榮俊香;云廣特高直流輸電系統(tǒng)換相失敗研究[D];昆明理工大學;2015年
3 王藝璇;靜止同步補償器對降低多饋入直流換相失敗的應用研究[D];山東大學;2015年
4 李剛;山東多饋入交直流混聯(lián)系統(tǒng)電磁暫態(tài)特性分析[D];山東大學;2015年
5 楊燦;哈鄭特高壓直流換相失敗對風電影響的仿真研究[D];華北電力大學;2015年
6 伊力亞爾·艾爾肯;超高壓直流輸電換相失敗對繼電保護的影響研究[D];新疆大學;2015年
7 劉俊勇;交流故障對HVDC系統(tǒng)換相失敗影響的機理分析[D];新疆大學;2015年
8 劉羽超;多饋入直流輸電換相失敗機理分析與防御措施研究[D];華北電力大學;2015年
9 費彬;HVDC換相失敗對交流保護的影響及對策[D];華北電力大學;2015年
10 張松濤;交直流輸電系統(tǒng)仿真及直流換相失敗研究[D];上海交通大學;2013年
本文編號:2473317
本文鏈接:http://sikaile.net/kejilunwen/dianlilw/2473317.html