新型三電平拓?fù)浣Y(jié)構(gòu)有源電力濾波器的研究
[Abstract]:The popularity of all kinds of power electronic equipment results in more and more harmonics in the distribution network. Increasingly sophisticated electronic devices demand better and cleaner electricity; on the contrary, the increase in power electronics has increased the amount of harmonics injected into the grid. In harmonic control, active power filter (APF) is highly efficient, fast, real-time and stable, so it has been paid attention to and applied in many fields. Three-phase four-wire active power filter (APF) has obvious advantages in harmonic control of distribution network and is attracting more and more attention. In this paper, a parallel three-phase four-wire active power filter (APF) is studied. The topology of the main circuit, the phase-locked loop (PLL) and the current-voltage closed-loop control strategy of APF are studied deeply. In this paper, two typical three-level converters and (Conergy NPC) three-level converters are compared and analyzed from the aspects of structure, cost, modulation method, loss distribution, and so on. The two typical three-level converters are compared and analyzed in terms of structure, cost, modulation method, loss distribution and so on. The results show that Conergy NPC has the highest comprehensive cost-to-performance ratio, and has obvious advantages in cost and loss balance. On this basis, the APF mathematical model based on the converter is established. Secondly, this paper studies the traditional software phase-locked loop in single synchronous coordinate system, and points out that the software phase-locked loop has the problems of long adjustment time and steady-state error under the condition of three-phase voltage imbalance. In view of these shortcomings, the dynamic and steady-state performance of phase-locked loop is effectively improved by improving the response speed and eliminating the steady-state error by filtering the negative sequence voltage components, and the simulation results show that the proposed method can effectively improve the dynamic and steady-state performance of the phase-locked loop. Then, aiming at the disadvantage that PI can't track AC signal without static error and the response time of repetitive control is long, a hybrid current control strategy with parallel connection is proposed, and a detailed parameter setting method is given. The control strategy has the advantages of fast response, high steady-state precision, and simple and convenient realization. At the same time, in order to ensure the stable operation of the system, the DC side voltage closed-loop control and voltage sharing control are analyzed and the parameters are designed respectively. The current and voltage control mentioned above are simulated and verified in this paper. Finally, the new three-level active power filter proposed in this paper is verified by experiments. The experimental results show that the new structure and the current and voltage control strategy are effective.
【學(xué)位授予單位】:哈爾濱工業(yè)大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2014
【分類號】:TM761
【共引文獻(xiàn)】
相關(guān)會議論文 前10條
1 丁仁杰;曹政;樊淼;;平衡單相負(fù)荷的補(bǔ)償容量優(yōu)化控制的SVC控制系統(tǒng)研究[A];第二十九屆中國控制會議論文集[C];2010年
2 任明煒;孫玉坤;饒翔;;無源濾波器優(yōu)化方法研究[A];第二十九屆中國控制會議論文集[C];2010年
3 苑舜;郭峰;;混合有源電力濾波器設(shè)計(jì)及其在諧波治理中的應(yīng)用[A];創(chuàng)新沈陽文集(A)[C];2009年
4 陸繼志;;220kV元謀變電站工業(yè)動態(tài)無功補(bǔ)償新技術(shù)STATCOM工程試驗(yàn)項(xiàng)目建設(shè)的意義[A];2010年云南電力技術(shù)論壇論文集(文摘部分)[C];2010年
5 劉暉;;淺析TSC無功補(bǔ)償裝置[A];第四屆安徽科技論壇安徽省電機(jī)工程學(xué)會分論壇論文集[C];2006年
6 劉國海;薛文平;;基于改進(jìn)型諧波檢測方法的并聯(lián)型有源濾波器的閉環(huán)控制[A];2005年全國自動化新技術(shù)學(xué)術(shù)交流會論文集[C];2005年
7 李可;徐偉;司小慶;;電力系統(tǒng)兩種無功補(bǔ)償方式及比較研究[A];2007中國繼電保護(hù)及自動化行業(yè)年會論文集[C];2007年
8 李益華;段虎;;基于DSP的諧波檢測裝置的設(shè)計(jì)[A];中國自動化學(xué)會中南六。▍^(qū))2010年第28屆年會·論文集[C];2010年
9 陳駿峰;楊璇;徐金榜;沈安文;;電網(wǎng)電壓波動對有源濾波器的影響及仿真分析[A];中南六。▍^(qū))自動化學(xué)會第二十九屆學(xué)術(shù)年會論文集[C];2011年
10 陳喬夫;李達(dá)義;柯建興;熊婭俐;賈正春;;一種大容量的串聯(lián)型有源電力濾波器[A];湖北省電工技術(shù)學(xué)會2004年學(xué)術(shù)年會論文集[C];2004年
相關(guān)博士學(xué)位論文 前10條
1 謝斌;并聯(lián)型有源電力濾波器諧波檢測及控制技術(shù)研究[D];華中科技大學(xué);2010年
2 田軍;多繞組變壓器式可調(diào)電抗的研究與應(yīng)用[D];華中科技大學(xué);2010年
3 雷之力;微網(wǎng)諧波振及電壓暫降的評估與控制[D];華北電力大學(xué)(北京);2011年
4 謝維;在線圈中心測量磁場垂直分量的頻率域電磁測深方法研究[D];中南大學(xué);2011年
5 蔣奇云;廣域電磁測深儀關(guān)鍵技術(shù)研究[D];中南大學(xué);2010年
6 張軍偉;異步電動機(jī)高頻斬波串級調(diào)速系統(tǒng)模型及特性的研究[D];華北電力大學(xué);2011年
7 于晶榮;低壓配電網(wǎng)有源電力濾波器關(guān)鍵技術(shù)研究[D];湖南大學(xué);2009年
8 夏向陽;大功率注入式有源電力濾波器的理論研究及工程應(yīng)用[D];湖南大學(xué);2009年
9 王小華;基于神經(jīng)網(wǎng)絡(luò)的數(shù)字濾波器設(shè)計(jì)及諧波檢測理論與方法研究[D];湖南大學(xué);2009年
10 盤宏斌;綜合型電能質(zhì)量調(diào)節(jié)裝置的理論與技術(shù)研究[D];湖南大學(xué);2009年
相關(guān)碩士學(xué)位論文 前10條
1 張?jiān)撇?基于DSP的三相四線制有源電力濾波器的研究[D];山東科技大學(xué);2010年
2 徐坤山;三相四線制并聯(lián)型有源電力濾波器的研究[D];山東科技大學(xué);2010年
3 李宜娟;基于ATMEGA64的磁閥式可控電抗器的控制研究[D];長春理工大學(xué);2010年
4 付邦勝;動態(tài)電壓恢復(fù)器控制研究[D];鄭州大學(xué);2010年
5 呂世家;多模塊并聯(lián)DC/AC電力變換技術(shù)研究[D];哈爾濱工程大學(xué);2010年
6 李建軍;基于電力系統(tǒng)的電能質(zhì)量檢測與分析[D];哈爾濱工程大學(xué);2010年
7 許明;并聯(lián)型三相三線制有源電力濾波器的仿真研究[D];大連理工大學(xué);2010年
8 張冠洲;基于DFACTS的電力牽引諧波抑制與節(jié)能研究[D];大連理工大學(xué);2010年
9 李太峰;6KV煤礦供電網(wǎng)混合有源濾波器的研究[D];遼寧工程技術(shù)大學(xué);2009年
10 馮凱輝;風(fēng)電場動態(tài)無功補(bǔ)償方案設(shè)計(jì)[D];長沙理工大學(xué);2010年
本文編號:2435921
本文鏈接:http://sikaile.net/kejilunwen/dianlilw/2435921.html