AP1000核電主管道加熱過(guò)程溫度
發(fā)布時(shí)間:2018-10-11 11:20
【摘要】:建立了主管道三維有限元模型,借助ANSYS軟件對(duì)其加熱過(guò)程進(jìn)行溫度場(chǎng)、應(yīng)力場(chǎng)的計(jì)算。采用分段加熱,第一階段初始溫度為20℃,加熱速度范圍為1.5℃/min到24℃/min。加熱至600℃保溫0~5 h。第二階段加熱速度范圍為2.5℃/min到24℃/min,加熱至1100℃保溫0~3 h。研究了不同加熱速度及均熱時(shí)間對(duì)管道溫度場(chǎng)、應(yīng)力場(chǎng)的影響。分析結(jié)果表明,以1.5℃/min加熱到600℃保溫5 h然后再以2.5℃/min加熱到1100℃,保溫3 h,在該工藝下主管道不會(huì)發(fā)生塑形畸變,且比實(shí)際加熱工藝時(shí)間更短,可為今后制定主管道加熱工藝提供參考。
[Abstract]:The three-dimensional finite element model of the main pipeline is established. The temperature field and stress field of the heating process are calculated by ANSYS software. The initial temperature of the first stage is 20 鈩,
本文編號(hào):2264004
[Abstract]:The three-dimensional finite element model of the main pipeline is established. The temperature field and stress field of the heating process are calculated by ANSYS software. The initial temperature of the first stage is 20 鈩,
本文編號(hào):2264004
本文鏈接:http://sikaile.net/kejilunwen/dianlilw/2264004.html