小電流接地系統故障監(jiān)測高速數據采集系統研制
發(fā)布時間:2018-10-05 19:03
【摘要】:提出一種高性能的高速數據采集系統,該系統選用采樣頻率高達65MSPS的模數轉換(ADC)芯片,并采用以硬件方式實現控制并行性的現場可編程門陣列(FPGA),避免傳統控制器單線程運行難以實現高速采集的瓶頸。詳細介紹了數據采集系統的回路構成,并重點論述了FPGA的控制設計。實驗測試數據表明文中設計的高速數據采集系統能較好滿足小電流接地監(jiān)測系統的暫態(tài)數據分析的需求。
[Abstract]:A high speed data acquisition system with high performance is proposed. The (ADC) chip with sampling frequency up to 65MSPS is used in the system. The field programmable gate array (FPGA), which realizes the control parallelism by hardware, is used to avoid the bottleneck of high speed acquisition in the single thread running of traditional controller. The circuit structure of data acquisition system is introduced in detail, and the control design of FPGA is emphasized. The experimental data show that the high speed data acquisition system designed in this paper can meet the needs of transient data analysis of small current grounding monitoring system.
【作者單位】: 廣東電網公司佛山供電局;浙江大學電氣工程學院;
【分類號】:TM862
[Abstract]:A high speed data acquisition system with high performance is proposed. The (ADC) chip with sampling frequency up to 65MSPS is used in the system. The field programmable gate array (FPGA), which realizes the control parallelism by hardware, is used to avoid the bottleneck of high speed acquisition in the single thread running of traditional controller. The circuit structure of data acquisition system is introduced in detail, and the control design of FPGA is emphasized. The experimental data show that the high speed data acquisition system designed in this paper can meet the needs of transient data analysis of small current grounding monitoring system.
【作者單位】: 廣東電網公司佛山供電局;浙江大學電氣工程學院;
【分類號】:TM862
【參考文獻】
相關期刊論文 前9條
1 薛永端,吳敏,王俊江,馮祖仁,徐為綱,徐丙垠;一種電壓型配電網單相接地故障處理方法[J];電力系統自動化;2002年12期
2 張偉剛;張保會;胡海松;徐靖東;周良才;;應用小波包分析實現配電網單相接地故障選線[J];電力系統自動化;2009年23期
3 唐金銳;尹項根;張哲;楊晨;葉磊;戚宣威;林th;;配電網故障自動定位技術研究綜述[J];電力自動化設備;2013年05期
4 吳樂鵬;黃純;林達斌;朱智軍;蔣洪濤;;基于暫態(tài)小波能量的小電流接地故障選線新方法[J];電力自動化設備;2013年05期
5 徐偉宗;;采樣頻率對行波測距影響的仿真分析[J];電力系統及其自動化學報;2014年06期
6 郭清滔;吳田;;小電流接地系統故障選線方法綜述[J];電力系統保護與控制;2010年02期
7 曾祥君,尹項根,于永源,陳德樹;基于注入變頻信號法的經消弧線圈接地系統控制與保護新方法[J];中國電機工程學報;2000年01期
8 賈清泉,劉連光,楊以涵,宋家驊;應用小波檢測故障突變特性實現配電網小電流故障選線保護[J];中國電機工程學報;2001年10期
9 王s,
本文編號:2254522