計(jì)及PMU量測(cè)的分步線(xiàn)性狀態(tài)估計(jì)模型
發(fā)布時(shí)間:2018-09-03 20:06
【摘要】:提出一種基于廣域量測(cè)系統(tǒng)(wide area measurement system,WAMS)和數(shù)據(jù)采集與監(jiān)控(supervisory control and data acquisition,SCADA)系統(tǒng)混合量測(cè)的電力系統(tǒng)狀態(tài)估計(jì)方法,該方法充分利用相量測(cè)量單元(phasor measurement unit,PMU)量測(cè)方程為線(xiàn)性方程的特點(diǎn),將SCADA量測(cè)方程分解為兩步線(xiàn)性化方程,并將PMU量測(cè)數(shù)據(jù)中的電壓幅值平方、電流幅值平方和相角量測(cè)分別添加到2個(gè)線(xiàn)性化方程中,從而實(shí)現(xiàn)PMU和SCADA混合量測(cè)狀態(tài)估計(jì)的非迭代計(jì)算,提高了計(jì)算效率。通過(guò)IEEE標(biāo)準(zhǔn)系統(tǒng)和波蘭電網(wǎng)仿真算例,驗(yàn)證了所提方法的有效性。
[Abstract]:A power system state estimation method based on hybrid measurements of wide area measurement system (WAMS) and supervisory control and data acquisition (SCADA) systems is proposed. The method makes full use of the characteristics of the phasor measurement unit (PMU) measurement equation as a linear equation. The SCADA measurement equation is decomposed into two-step linearization equations. Voltage amplitude squared, current amplitude squared and phase angle measurements in PMU measurement data are added to the two linearization equations respectively. The non-iterative calculation of PMU and SCADA mixed measurement state estimation is realized and the computational efficiency is improved. The validity of the proposed method is verified by a real example.
【作者單位】: 河海大學(xué)能源與電氣學(xué)院;國(guó)網(wǎng)電力科學(xué)研究院;
【基金】:國(guó)家自然科學(xué)基金項(xiàng)目(51107032,61104045,51277052) 國(guó)家電網(wǎng)公司科技項(xiàng)目(考慮通信信息系統(tǒng)風(fēng)險(xiǎn)的電網(wǎng)安全穩(wěn)定防御關(guān)鍵技術(shù)研究)~~
【分類(lèi)號(hào)】:TM933.31
[Abstract]:A power system state estimation method based on hybrid measurements of wide area measurement system (WAMS) and supervisory control and data acquisition (SCADA) systems is proposed. The method makes full use of the characteristics of the phasor measurement unit (PMU) measurement equation as a linear equation. The SCADA measurement equation is decomposed into two-step linearization equations. Voltage amplitude squared, current amplitude squared and phase angle measurements in PMU measurement data are added to the two linearization equations respectively. The non-iterative calculation of PMU and SCADA mixed measurement state estimation is realized and the computational efficiency is improved. The validity of the proposed method is verified by a real example.
【作者單位】: 河海大學(xué)能源與電氣學(xué)院;國(guó)網(wǎng)電力科學(xué)研究院;
【基金】:國(guó)家自然科學(xué)基金項(xiàng)目(51107032,61104045,51277052) 國(guó)家電網(wǎng)公司科技項(xiàng)目(考慮通信信息系統(tǒng)風(fēng)險(xiǎn)的電網(wǎng)安全穩(wěn)定防御關(guān)鍵技術(shù)研究)~~
【分類(lèi)號(hào)】:TM933.31
【參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 李碧君,薛禹勝,顧錦汶,韓禎祥;電力系統(tǒng)狀態(tài)估計(jì)問(wèn)題的研究現(xiàn)狀和展望[J];電力系統(tǒng)自動(dòng)化;1998年11期
2 趙紅嘎,薛禹勝,汪德星,葛敏輝,李碧君;計(jì)及PMU支路電流相量的狀態(tài)估計(jì)模型[J];電力系統(tǒng)自動(dòng)化;2004年17期
3 丁軍策;蔡澤祥;王克英;;基于廣域測(cè)量系統(tǒng)的狀態(tài)估計(jì)研究綜述[J];電力系統(tǒng)自動(dòng)化;2006年07期
4 李大路;李蕊;孫元章;陳涵;;利用PMU數(shù)據(jù)提高電力系統(tǒng)狀態(tài)估計(jì)精度的方法[J];電網(wǎng)技術(shù);2009年03期
5 林桂華;安天瑜;周蘇荃;張艷軍;孫明一;;計(jì)及PMU量測(cè)信息的量測(cè)量變換狀態(tài)估計(jì)[J];電網(wǎng)技術(shù);2009年17期
6 李欽;項(xiàng)鳳雛;顏偉;盧建剛;余娟;陳俊;李世明;;基于SCADA及PMU多時(shí)段量測(cè)信息的獨(dú)立線(xiàn)路參數(shù)估計(jì)方法[J];電網(wǎng)技術(shù);2011年02期
7 傅書(shū),
本文編號(hào):2221035
本文鏈接:http://sikaile.net/kejilunwen/dianlilw/2221035.html