電流互感器暫態(tài)飽和特性及差動保護(hù)應(yīng)對措施研究
[Abstract]:With the rapid development of power construction, the scale of power network is getting larger and larger, the structure is more and more complex, and the transient process is becoming more complex and diverse, which will test the transient performance of current transformer (TA). Field accident analysis shows that the core saturation of current transformer caused by transient process is an important reason for the maloperation of current differential protection. The differential protection is usually used as the main protection of the power equipment, and its misoperation will cause serious harm to the safety of the equipment itself and the stable operation of the system. Therefore, it is of great theoretical and practical significance to study the transient saturation characteristics of current transformers and the corresponding strategies of differential protection in order to ensure the safety of power network operation and improve the reliability of power supply. The transient saturation characteristics of current transformers are complex and affected by many nonlinear factors. Digital simulation and dynamic simulation test are the basic methods and means to study the transient saturation characteristics of TA. According to TA saturation mechanism, several typical current transformer simulation modeling methods are compared and analyzed, and the rationality of TA simulation model based on J-A theory is demonstrated. According to the principle of magnetodynamic potential equivalence, a method of constructing the physical test model of current transformer based on the principle of magnetic chain equivalence is proposed, which can be directly used in the dynamic model test research of the actual current transformer. The realization method of the physical model and the result of dynamic model test are introduced in this paper. Transient saturation of current transformer is one of the main causes of maloperation of differential protection. The characteristics of the secondary current waveform after the TA core is saturated are analyzed in this paper. On this basis, the basic principles and implementation methods of current differential protection anti-TA saturation algorithms, such as harmonic braking method, moveout method, additional braking zone method, current polarity comparison method and sampled-value differential method, are classified and expounded. It provides a reference for the evaluation of TA saturation resistance of differential protection. Based on the above research work, the TA saturation caused by transformer inrush current is analyzed in view of the maloperation of generator differential protection and line differential protection when the transformer is empty. The main causes of maloperation of differential protection are brought forward. The necessity of strengthening anti-TA saturation measures in differential protection of generator and line and the countermeasures to be taken are put forward. A new differential protection method based on small vectors is proposed to solve the delay problem of differential protection when the current harmonic braking method may lead to the fault in the region. The basic principle, realization method and test results of this method are introduced in this paper. At the end of the paper, the paper summarizes the work of the paper, and looks forward to the next work.
【學(xué)位授予單位】:華中科技大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2014
【分類號】:TM452
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 黃祥敏;黃輝;;變壓器比率差動保護(hù)仿真分析[J];電工技術(shù);2009年12期
2 茍秦晉;趙金;李海帆;張文輝;;淺析變壓器的差動保護(hù)[J];經(jīng)營管理者;2009年23期
3 張未央;差動保護(hù)部分校驗的改進(jìn)方法[J];繼電器;1995年04期
4 朱聲石;差動保護(hù)采用P級電流互感器的問題[J];繼電器;2000年07期
5 張東升;;差動保護(hù)換型分析[J];電氣試驗;2000年02期
6 高國慶,王曉宏,陳學(xué)珍,陶建軍;雙圈變五側(cè)制動差動保護(hù)的可行方案[J];華東電力;2001年05期
7 高國慶;雙圈變壓器5側(cè)制動差動保護(hù)的實現(xiàn)方案[J];繼電器;2001年07期
8 李干林,鄧東華,黃瑛;新型差動保護(hù)判據(jù)探討[J];南京工程學(xué)院學(xué)報;2002年03期
9 李建斌,張順;變壓器兩種差動保護(hù)方式的比較[J];西山科技;2002年S1期
10 楊彪;國外220kV差動保護(hù)的特點原理分析[J];繼電器;2003年07期
相關(guān)會議論文 前10條
1 劉春華;;電力變壓器比率制動式差動保護(hù)的原理及分析[A];第七屆(2009)中國鋼鐵年會論文集(下)[C];2009年
2 邱慶濤;;比率差動保護(hù)在南京東變電所微保改造中的問題總結(jié)[A];江蘇省鐵道學(xué)會2009年度獲獎?wù)撐膶]媅C];2009年
3 金啟超;劉明輝;吉擁平;崔得志;王海兵;;比率差動保護(hù)的定值誤差評價問題[A];2008中國電力系統(tǒng)保護(hù)與控制學(xué)術(shù)研討會論文集[C];2008年
4 朱佳杰;邰能靈;胡浩;;一種發(fā)電機(jī)差動保護(hù)的新方案[A];2007中國繼電保護(hù)及自動化行業(yè)年會論文集[C];2007年
5 胡年勝;季華鋒;;一次電動機(jī)差動保護(hù)故障的分析[A];全國冶金自動化信息網(wǎng)2014年會論文集[C];2014年
6 周洋;帥網(wǎng)蘭;;發(fā)電機(jī)的差動保護(hù)[A];第九屆全國內(nèi)河船舶及航運技術(shù)學(xué)術(shù)交流會論文集[C];2004年
7 代偉;;分相差動保護(hù)試驗分析[A];2011年云南電力技術(shù)論壇論文集(入選部分)[C];2011年
8 李紅霞;;互感器二次配線對電動機(jī)差動保護(hù)的影響[A];2009首屆全國水泥企業(yè)節(jié)電新技術(shù)交流會暨鴻升科技節(jié)電新技術(shù)聯(lián)誼會論文集[C];2009年
9 石恒初;翟海燕;左曉錚;趙明;李本瑜;;一起500kV變壓器零序差動保護(hù)誤動事故的分析[A];2012年云南電力技術(shù)論壇論文集(文摘部分)[C];2012年
10 文明浩;陳德樹;尹項根;張哲;;等傳變瞬時值差動保護(hù)分析[A];2007中國繼電保護(hù)及自動化行業(yè)年會論文集[C];2007年
相關(guān)重要報紙文章 前2條
1 江西 陶波 劉學(xué);大型電機(jī)易發(fā)差動保護(hù)故障分析與處理[N];電子報;2010年
2 國電華北電力設(shè)計院工程有限公司 張純崗;國外兩種零序差動保護(hù)介紹[N];機(jī)電商報;2006年
相關(guān)博士學(xué)位論文 前3條
1 及洪泉;基于OCT的線路差動保護(hù)及變電站自動化系統(tǒng)研究[D];華北電力大學(xué)(北京);2007年
2 金明亮;大型發(fā)變組復(fù)雜異常工況下主保護(hù)新技術(shù)研究[D];華中科技大學(xué);2010年
3 鄭曉冬;特高壓直流輸電線路保護(hù)新原理研究[D];上海交通大學(xué);2013年
相關(guān)碩士學(xué)位論文 前10條
1 周建萍;和應(yīng)涌流導(dǎo)致差動保護(hù)誤動的原因與對策研究[D];昆明理工大學(xué);2015年
2 董文秀;電流互感器暫態(tài)飽和特性及差動保護(hù)應(yīng)對措施研究[D];華中科技大學(xué);2014年
3 楊青;考慮電流互感器飽和影響的差動保護(hù)新判據(jù)的研究[D];華北電力大學(xué)(北京);2007年
4 李海濤;電流互感器飽和對差動保護(hù)的影響及解決方案[D];華北電力大學(xué)(北京);2003年
5 葉志剛;差動保護(hù)在上海市區(qū)電網(wǎng)中的應(yīng)用分析及改進(jìn)[D];上海交通大學(xué);2011年
6 張文哲;自適應(yīng)發(fā)電機(jī)差動保護(hù)的研究[D];西安科技大學(xué);2009年
7 由偉翰;基于故障信號同步的配網(wǎng)差動保護(hù)技術(shù)[D];山東大學(xué);2009年
8 譚愷;電力變壓器保護(hù)裝置研發(fā)與抗干擾設(shè)計[D];湖南科技大學(xué);2014年
9 晏玲;一種新型變壓器差動保護(hù)判據(jù)的研究[D];華北電力大學(xué)(北京);2003年
10 甄樹義;電力系統(tǒng)主設(shè)備繼電保護(hù)整定計算軟件的開發(fā)[D];華北電力大學(xué)(河北);2005年
本文編號:2174847
本文鏈接:http://sikaile.net/kejilunwen/dianlilw/2174847.html