配電網(wǎng)消弧與故障定位技術(shù)的研究
本文選題:配電網(wǎng) + 消弧線圈。 參考:《福州大學(xué)》2014年碩士論文
【摘要】:6kV-35kV配電網(wǎng)是電力系統(tǒng)中電能的輸送和分配的重要環(huán)節(jié),配電網(wǎng)單相接地故障頻發(fā)已是一個不爭的事實(shí)。若配電網(wǎng)單相接地故障所產(chǎn)生的接地電弧短時(shí)內(nèi)無法消除導(dǎo)致線路跳閘將直接影響到對用戶供電的連續(xù)性,給人民生活和社會生產(chǎn)帶來極大不便,所以配電網(wǎng)的安全穩(wěn)定運(yùn)行在整個電力系統(tǒng)中占有重要地位。而配電網(wǎng)的中性點(diǎn)接地方式直接關(guān)系著配電網(wǎng)消除接地電弧的能力和配電網(wǎng)的故障跳閘率。目前我國6kV-35kV的中壓配電網(wǎng)大多采用中性點(diǎn)經(jīng)消弧線圈的接地方式。但市面上的消弧線圈成套裝置普遍無法滿足響應(yīng)快,補(bǔ)償效果快,伏安特性的線性度好,并且可以連續(xù)地在大范圍內(nèi)調(diào)節(jié)等要求。而且若要極大降低配電網(wǎng)的故障跳閘率,還需要配備快速、準(zhǔn)確、可靠的小電流接地選線裝置及配套的保護(hù)跳閘裝置與消弧線圈控制相配合。為了綜合解決以上問題,作者在總結(jié)消弧線圈自動調(diào)諧成套裝置數(shù)年運(yùn)行經(jīng)驗(yàn)的基礎(chǔ)上,深入研究了新型的快速高短路阻抗型變壓器式消弧線圈配套自動跟蹤調(diào)諧消弧線圈(ATASC)裝置。本文提出的新型成套裝置其高壓側(cè)配置的消弧線圈是調(diào)匝式的,這主要是從系統(tǒng)的可靠性出發(fā)。當(dāng)系統(tǒng)異常(電流互感器、電壓互感器斷線,或者裝置失電)和發(fā)生單相故障接地時(shí)閉鎖了消弧線圈有載調(diào)壓開關(guān),它所補(bǔ)償感性電流并不需要二次設(shè)備來調(diào)節(jié),保證了系統(tǒng)的可靠運(yùn)行。此外,本套裝置阻尼電阻的保護(hù),是當(dāng)單相接地故障發(fā)生時(shí),憑借阻尼電阻自身電壓觸發(fā)大功率的可控硅,控制阻尼電阻在1毫秒快速短接。當(dāng)接地故障消除后,控制可控硅自然關(guān)斷。所以無需在阻尼電阻箱接入直流電源或交流電源,這種保護(hù)方式,可以使一、二次設(shè)備完全分開。新型成套裝置可根據(jù)實(shí)際需要,還可完成兩臺及多臺消弧線圈的并聯(lián)運(yùn)行。另外本文考慮了市面上的選線裝置的優(yōu)缺點(diǎn),提出了并聯(lián)中電阻選線法。并聯(lián)中電阻選線法參照國外技術(shù)采用在消弧線圈兩端并聯(lián)電阻的方法,在接地時(shí)向故障點(diǎn)增加零序電流的有功分量,引起故障點(diǎn)的電流的相位和幅度均發(fā)生顯著的波動,接地選線的準(zhǔn)確性接近100%。最后,通過實(shí)際運(yùn)行分析結(jié)果證明本文提出的配電網(wǎng)消弧線圈與故障選線成套裝置的方案是可行的,具有一定的先進(jìn)性。
[Abstract]:6kV-35kV distribution network is an important link in the transmission and distribution of electric energy in power system. It is an indisputable fact that single-phase grounding faults occur frequently in distribution network. If the grounding arc caused by single-phase grounding fault in distribution network can not be eliminated in a short time, the tripping will directly affect the continuity of power supply to users and bring great inconvenience to people's life and social production. Therefore, the safe and stable operation of distribution network plays an important role in the whole power system. The neutral grounding mode of the distribution network is directly related to the ability of the distribution network to eliminate the grounding arc and the fault tripping rate of the distribution network. At present, 6 kV V-35 kV medium-voltage distribution network mostly uses neutral point grounding through arc-suppression coil. However, the complete set of arc-suppression coil on the market can not meet the requirements of fast response, fast compensation effect, good linearity of volt-ampere characteristics, and can be continuously adjusted in a wide range. In order to greatly reduce the tripping rate of distribution network, it is also necessary to provide fast, accurate and reliable small current grounding line selection device and matching protection tripping device to cooperate with arc suppression coil control. In order to solve the above problems comprehensively, the author summarizes the operation experience of the automatic tuning complete set of arc-suppression coil for several years. A new type of fast and high short circuit impedance transformer type arc-suppression coil (ATASC) is studied in this paper. In this paper, a new type of equipment is presented, which is mainly based on the reliability of the system. When the system is abnormal (current transformer, voltage transformer disconnected, or the device is out of power) and when a single phase fault occurs, the arc suppression coil load regulator is blocked, and the inductive current compensated by it does not need to be adjusted by secondary equipment. It ensures the reliable operation of the system. In addition, the protection of the damping resistance of the device is to trigger the high power thyristor with the damping resistance voltage when the single-phase grounding fault occurs, and to control the damping resistance to be connected quickly in 1 millisecond. When the grounding fault is eliminated, the control SCR is turned off naturally. Therefore, there is no need to connect DC or AC power in the damped resistance box. This kind of protection can separate the primary and secondary equipments completely. According to the actual needs, two or more arc-suppression coils can be operated in parallel. In addition, considering the merits and demerits of the line selection devices in the market, a parallel middle resistance line selection method is proposed. With reference to the foreign technology, the method of parallel resistance selection in parallel middle resistance increases the active power component of zero sequence current to the fault point when grounding, which causes the phase and amplitude of the fault point current to fluctuate significantly, and the method of parallel resistance at the two ends of the arc-suppression coil is used to increase the active power component of the zero sequence current to the fault point when grounded. The accuracy of grounding line selection is close to 100. Finally, it is proved that the scheme of arc-suppression coil and fault line selection in this paper is feasible and advanced.
【學(xué)位授予單位】:福州大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2014
【分類號】:TM727
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 謝正寧;消弧線圈的操作和異常處理[J];農(nóng)村電氣化;2002年12期
2 楊紅星;消弧線圈的選型和應(yīng)用[J];現(xiàn)代電子技術(shù);2005年20期
3 鄧岳華;胡曉萌;區(qū)偉潮;;消弧線圈的幾個常見問題[J];農(nóng)村電氣化;2006年05期
4 楊萬和;張常全;趙裕民;張惠敏;;老式消弧線圈改造方案[J];中國科技信息;2006年09期
5 劉紅麗;;消弧線圈的調(diào)整及運(yùn)行操作[J];農(nóng)村電氣化;2009年11期
6 胡玉霞;馮苗;;電力消弧線圈綜述[J];硅谷;2010年14期
7 王健;;消弧柜與消弧線圈的比較[J];中國新通信;2013年16期
8 姜新宇;陸國慶;周良才;;對消弧線圈若干問題的探討[J];電力設(shè)備;2000年Z1期
9 張常全,趙裕民;老式消弧線圈存在的問題及改造的必要性[J];電網(wǎng)技術(shù);2001年05期
10 陸國慶,姜新宇;影響消弧線圈應(yīng)用效果的重要性能[J];電網(wǎng)技術(shù);2001年11期
相關(guān)會議論文 前10條
1 李嗣明;何婧;張熙軍;陳飛;駱云峰;王磊;;消弧線圈投入后引起系統(tǒng)電壓不平衡原因分析及解決辦法[A];2008中國電力系統(tǒng)保護(hù)與控制學(xué)術(shù)研討會論文集[C];2008年
2 黃麗英;程漢湘;;一種新型的磁通可控消弧線圈的仿真研究[A];武漢(南方九省)電工理論學(xué)會第22屆學(xué)術(shù)年會、河南省電工技術(shù)學(xué)會年會論文集[C];2010年
3 王復(fù)興;顏士華;;消弧線圈自動調(diào)節(jié)原理的研究[A];第十一屆全國煤礦自動化學(xué)術(shù)年會論文專輯[C];2001年
4 顧精彩;;有載開關(guān)調(diào)匝式消弧線圈的特點(diǎn)及其在電力系統(tǒng)中的應(yīng)用[A];全國電網(wǎng)中性點(diǎn)接地方式與接地技術(shù)研討會論文集[C];2005年
5 田效禮;劉清源;;接地變與消弧線圈研究與探討[A];山東電機(jī)工程學(xué)會第五屆供電專業(yè)學(xué)術(shù)交流會論文集[C];2008年
6 劉金濤;;發(fā)電機(jī)消弧線圈參數(shù)試驗(yàn)驗(yàn)證方法研究[A];全國火電大機(jī)組(300MW級)競賽第三十五屆年會論文集[C];2006年
7 王科;趙現(xiàn)平;;中性點(diǎn)經(jīng)消弧線圈接地方式下“虛接地”問題的探討[A];2009年云南電力技術(shù)論壇論文集(文摘部分)[C];2009年
8 魏岱寧;周海斌;徐振棟;;論單相接地電容電流危害及消弧線圈的發(fā)展[A];煤礦自動化與信息化——第19屆全國煤礦自動化與信息化學(xué)術(shù)會議暨中國礦業(yè)大學(xué)(北京)百年校慶學(xué)術(shù)會議論文集[C];2009年
9 韋良;韋景;張洪瑾;;偏磁式消弧線圈接地新技術(shù)[A];中國高等學(xué)校電力系統(tǒng)及其自動化專業(yè)第二十四屆學(xué)術(shù)年會論文集(中冊)[C];2008年
10 裴繼東;馬玉昌;侯慧卿;王學(xué)禮;張真濤;;消弧線圈接地警示訊號裝置的改進(jìn)[A];經(jīng)濟(jì)策論(下)[C];2011年
相關(guān)重要報(bào)紙文章 前2條
1 西山煤礦總公司官地礦 王桂莉;淺談煤礦供電系統(tǒng)裝設(shè)消弧圈的問題[N];山西科技報(bào);2005年
2 記者 江萌 實(shí)習(xí)生 王慧 何祝君 通訊員 王欣 鄒祖虎;武昌方圓幾公里面臨斷電[N];湖北日報(bào);2010年
相關(guān)博士學(xué)位論文 前6條
1 江渝;快速可連續(xù)調(diào)節(jié)消弧線圈諧振接地系統(tǒng)的研究[D];重慶大學(xué);2005年
2 曲軼龍;全補(bǔ)償消弧線圈及其控制方法的研究[D];華北電力大學(xué)(北京);2008年
3 賈晨曦;全電流補(bǔ)償消弧線圈關(guān)鍵技術(shù)研究[D];中國礦業(yè)大學(xué);2014年
4 劉和平;新型快速可調(diào)消弧線圈接地系統(tǒng)研究[D];重慶大學(xué);2004年
5 潘貞存;消弧線圈自動跟蹤補(bǔ)償與接地選線定位技術(shù)的研究[D];山東大學(xué);2006年
6 程路;變壓器負(fù)載可控的新型消弧線圈接地系統(tǒng)研究[D];華中科技大學(xué);2008年
相關(guān)碩士學(xué)位論文 前10條
1 何建安;配電網(wǎng)消弧與故障定位技術(shù)的研究[D];福州大學(xué);2014年
2 李天旭;偏磁式消弧線圈控制的研究[D];華北電力大學(xué)(河北);2009年
3 李原;主輔式消弧線圈控制系統(tǒng)的研究與軟件開發(fā)[D];華北電力大學(xué)(北京);2010年
4 陳恒;不同消弧線圈性能分析與試驗(yàn)驗(yàn)證[D];上海交通大學(xué);2007年
5 賀鵬程;基于磁通可控原理的新型消弧線圈系統(tǒng)的研制[D];華中科技大學(xué);2004年
6 廖玉波;偏磁式消弧線圈的全數(shù)字化控制系統(tǒng)研究[D];山東科技大學(xué);2006年
7 賀琳;有源消弧線圈技術(shù)的研究[D];西安科技大學(xué);2011年
8 汪軍;用于消弧線圈性能研究的高壓模擬電網(wǎng)及分析測試系統(tǒng)[D];上海交通大學(xué);2007年
9 趙勇;消弧線圈配置優(yōu)化的研究[D];華北電力大學(xué);2012年
10 牛卓博;消弧線圈在保定電網(wǎng)的應(yīng)用研究[D];華北電力大學(xué);2012年
,本文編號:1999990
本文鏈接:http://sikaile.net/kejilunwen/dianlilw/1999990.html