云數(shù)據(jù)中心與高壓變電站共站時(shí)的工頻磁場環(huán)境特征
本文選題:云數(shù)據(jù)中心 + 高壓變電站。 參考:《高電壓技術(shù)》2015年11期
【摘要】:云數(shù)據(jù)中心(IDC)與高壓變電站共站建設(shè)時(shí),變電站正常工作時(shí)的穩(wěn)態(tài)持續(xù)工頻磁場和短路時(shí)的短時(shí)工頻磁場可能會(huì)威脅共站建設(shè)云數(shù)據(jù)中心的信息存儲(chǔ)設(shè)備的安全運(yùn)行。為此,通過分析測量結(jié)果及國內(nèi)外數(shù)據(jù),系統(tǒng)總結(jié)了高壓變電站產(chǎn)生的工頻磁場環(huán)境的特征,提出了不同電壓等級(jí)變電站母線、地下變電站、地下電纜、電抗器及電容器產(chǎn)生的穩(wěn)態(tài)持續(xù)工頻磁場強(qiáng)度最大值分別為64 A/m、45 A/m、49 A/m、4 000 A/m、800 A/m,通過計(jì)算分析了變電站工頻短路時(shí)50 k A短路電流在附近產(chǎn)生的短時(shí)工頻磁場強(qiáng)度最大值可達(dá)2 490 A/m。研究結(jié)果表明:在云數(shù)據(jù)中心建設(shè)時(shí),需要控制云數(shù)據(jù)中心信息設(shè)備與電抗器的距離10 m,與電容器的距離5 m,以確保云數(shù)據(jù)中心信息設(shè)備承受的穩(wěn)態(tài)持續(xù)工頻磁場強(qiáng)度100 A/m;控制云數(shù)據(jù)中心信息設(shè)備與高壓母線的距離10 m,可將與變電站共站建設(shè)的云數(shù)據(jù)中心可能出現(xiàn)的短時(shí)工頻磁場強(qiáng)度降低到1 000 A/m。該研究結(jié)果為制定云數(shù)據(jù)中心與高壓變電站共站建設(shè)時(shí)的工頻磁場防護(hù)策略奠定了基礎(chǔ)。
[Abstract]:In the construction of cloud data center (IDC) and high voltage substation, the steady sustained power frequency magnetic field and the short time power frequency magnetic field during normal operation of the substation may threaten the safe operation of the information storage equipment in the construction of the cloud data center. Therefore, by analyzing the measurement results and domestic and foreign data, the characteristics of the power frequency magnetic field environment generated by high-voltage substation are systematically summarized, and the busbar, underground substation and underground cable of substation with different voltage levels are put forward. The maximum of the steady-state sustained power frequency magnetic field produced by reactor and capacitor is 64 A / m ~ (45) A / m ~ (1) ~ (49) A / m ~ (4) A ~ (4 000) A / m ~ (2 +) ~ (800) A / m, respectively. Through calculation and analysis, the maximum value of 50 Ka short circuit current produced in the vicinity of power frequency short circuit in substation is 2 490 A / m ~ (-1). The results show that: in the construction of cloud data center, The distance between the cloud data center information equipment and the reactor and the capacitor must be controlled by 10 m and 5 m respectively to ensure the steady-state sustained power frequency magnetic field intensity of 100 A / m; to control the cloud data center information equipment and The distance of high voltage bus can be reduced to 1 000 A / m from the short time power frequency magnetic field which may occur in the cloud data center built with substation. The results laid a foundation for establishing the protection strategy of power frequency magnetic field in the construction of cloud data center and high voltage substation.
【作者單位】: 清華大學(xué)電機(jī)工程與應(yīng)用電子技術(shù)系電力系統(tǒng)及發(fā)電設(shè)備控制與仿真國家重點(diǎn)實(shí)驗(yàn)室;中訊郵電咨詢?cè)O(shè)計(jì)院有限公司;華為技術(shù)有限公司全球認(rèn)證檢測中心;
【基金】:國家自然科學(xué)基金(51322703)~~
【分類號(hào)】:TP308;TM63
【參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 李永明;羅鵬;徐祿文;付志紅;;基于矩量法的變電站工頻磁場建模與計(jì)算[J];中國電機(jī)工程學(xué)報(bào);2015年16期
2 趙軍;陳維江;張建功;周卓懿;袁宇波;;智能變電站二次設(shè)備對(duì)開關(guān)瞬態(tài)的電磁兼容抗擾度要求分析[J];高電壓技術(shù);2015年05期
3 劉驍繁;崔翔;吳恒天;嵇建飛;焦重慶;;500kV氣體絕緣變電站開關(guān)操作對(duì)智能組件電流互感器端口電磁騷擾的實(shí)測及分析[J];高電壓技術(shù);2015年05期
4 嵇建飛;楊逸飛;袁宇波;王立輝;;智能變電站就地智能設(shè)備電磁兼容抗擾度試驗(yàn)分析[J];高電壓技術(shù);2015年03期
5 李湘權(quán);劉貴龍;傅宗;陸思全;;我國首個(gè)全地下500 kV輸變電工程電磁環(huán)境監(jiān)測分析[J];環(huán)保科技;2014年05期
6 杜華珠;文習(xí)山;魯海亮;姜志鵬;;35kV三相空心電抗器組的磁場分布[J];高電壓技術(shù);2012年11期
7 鞏延果;;500kV變電站站內(nèi)工頻電磁場檢測分析[J];廣西電力;2012年04期
8 杜志葉;阮江軍;干U喸,
本文編號(hào):1910405