考慮不確定因素的電力系統(tǒng)靜態(tài)安全預(yù)防控制
本文選題:電力系統(tǒng) + 靜態(tài)安全分析; 參考:《電力自動化設(shè)備》2014年02期
【摘要】:提出一種考慮不確定因素的電力系統(tǒng)靜態(tài)安全的預(yù)防控制方法。首先,給出一種考慮預(yù)想事故發(fā)生概率和負荷水平不確定性的系統(tǒng)靜態(tài)安全指標(biāo);然后通過將該指標(biāo)加入到預(yù)防控制模型中,得到考慮不確定因素的預(yù)防控制策略,重點考慮采用發(fā)電機出力再調(diào)整和切負荷作為控制手段。鑒于負荷特性對系統(tǒng)的影響很大,采用ZIP負荷模型。我國某實際系統(tǒng)的仿真算例結(jié)果驗證了所提方法的有效性。
[Abstract]:This paper presents a preventive control method for static safety of power system considering uncertain factors. Firstly, a system static safety index considering the uncertainty of probability and load level of expected accident is given, and then the preventive control strategy considering uncertain factors is obtained by adding the index to the preventive control model. Emphasis is placed on the use of generator output readjustment and load shedding as control measures. In view of the great influence of load characteristics on the system, ZIP load model is adopted. The effectiveness of the proposed method is verified by a simulation example of a practical system in China.
【作者單位】: 西北電力設(shè)計院;
【分類號】:TM732
【參考文獻】
相關(guān)期刊論文 前10條
1 文學(xué)鴻;袁越;鞠平;;靜態(tài)電壓穩(wěn)定負荷裕度分析方法比較[J];電力自動化設(shè)備;2008年05期
2 邱革非;束洪春;于繼來;;一種提高斷面功率傳輸能力的無功補償方法[J];電力自動化設(shè)備;2009年01期
3 隨慧斌;趙建國;李可軍;牛林;;考慮不均衡區(qū)域負荷增長的在線電壓穩(wěn)定評估[J];電力自動化設(shè)備;2011年03期
4 許琦;;“N-1”預(yù)想事故下滿足靜態(tài)電壓穩(wěn)定約束的快速ATC算法[J];電力自動化設(shè)備;2011年08期
5 胡學(xué)浩;美加聯(lián)合電網(wǎng)大面積停電事故的反思和啟示[J];電網(wǎng)技術(shù);2003年09期
6 印永華,郭劍波,趙建軍,卜廣全;美加“8.14”大停電事故初步分析以及應(yīng)吸取的教訓(xùn)[J];電網(wǎng)技術(shù);2003年10期
7 王錫凡;電力市場條件下電網(wǎng)的安全保證體系[J];電網(wǎng)技術(shù);2004年09期
8 傅旭;王錫凡;解利斌;;考慮N-1靜態(tài)安全的電力系統(tǒng)最大負荷能力計算方法[J];電網(wǎng)技術(shù);2006年06期
9 牟曉明;李志民;;一種計算電壓穩(wěn)定邊界的兩階段潮流方法[J];電力自動化設(shè)備;2013年03期
10 傅旭;付覽,
本文編號:1876689