本文選題:霧霾 + 復(fù)合絕緣子; 參考:《電網(wǎng)技術(shù)》2014年07期
【摘要】:為探究霧霾天氣對電力設(shè)備外絕緣的危害,以現(xiàn)場運(yùn)行的復(fù)合絕緣子進(jìn)行試驗(yàn)研究。霧霾對復(fù)合絕緣子的影響主要體現(xiàn)在2個(gè)方面:一是導(dǎo)致復(fù)合絕緣子表面積污量的增加;二是其產(chǎn)生的濕沉降會(huì)增加絕緣子的泄漏電流、降低閃絡(luò)電壓。利用河北省石家莊地區(qū)的霧霾天氣進(jìn)行了360 h的自然積污試驗(yàn),分別在不同的霧霾臟污程度下試驗(yàn)3次,研究污穢度和泄漏電流與霧霾的臟污程度及作用時(shí)間之間的關(guān)系。試驗(yàn)結(jié)果表明:霧霾天氣的發(fā)生會(huì)在短時(shí)間內(nèi)增加絕緣子表面的污穢度,在數(shù)十小時(shí)內(nèi)可以使絕緣子表面的等值鹽密增加0.01?0.04 mg/cm2、灰密值增加0.05?0.2 mg/cm2;空氣質(zhì)量指數(shù)不同,試品表面污穢度增加情況也不同;霧霾日數(shù)的增加是影響復(fù)合絕緣子表面污穢度的重要因素;霧霾產(chǎn)生的濕沉降會(huì)增加復(fù)合絕緣子的泄漏電流。短期內(nèi)霧霾天氣不會(huì)導(dǎo)致復(fù)合絕緣子發(fā)生污閃故障,但隨著霧霾作用時(shí)間的延長和環(huán)境污染的加劇,污閃的可能性是存在的。
[Abstract]:In order to explore the harm of fog and haze to the external insulation of electric power equipment, the composite insulators operated in the field are tested. The influence of haze on composite insulators is mainly reflected in 2 aspects: one is the increase of surface area pollution of composite insulators, and the two is that the wet deposition of the insulators will increase the leakage current of insulators and reduce the flashover voltage. The natural pollution test of 360 h was carried out in the haze weather in Shijiazhuang area of Hebei province. The relationship between pollution degree and leakage current and the effect time of fog and haze was studied 3 times under different degree of fog and haze. The results showed that the occurrence of haze weather would increase the surface of insulators in a short time. Contamination degree can increase the equivalent salt density of insulator surface by 0.01? 0.04 mg/cm2 in the last few hours and increase the ash density by 0.05? 0.2 mg/cm2, and the increase of surface pollution degree is different from the air mass index, and the increase of haze days is an important factor affecting the surface contamination of composite insulators; the wet deposition of haze will increase The leakage current of composite insulators. In the short term haze weather will not cause pollution flashover of composite insulators. However, the possibility of pollution flashover is possible with the prolongation of fog and haze time and the aggravation of environmental pollution.
【作者單位】: 華北電力大學(xué)電氣與電子工程學(xué)院;國網(wǎng)河北省電力科學(xué)研究院;青海省電力公司海西供電公司;
【基金】:國家自然科學(xué)基金項(xiàng)目(51177046) 中央高校基本科研業(yè)務(wù)費(fèi)專項(xiàng)資金項(xiàng)目(13MS71)~~
【分類號(hào)】:TM216
【參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 劉兆林;1996年末華東電網(wǎng)霧閃故障分析及對策[J];電網(wǎng)技術(shù);1997年08期
2 殷禹;梁曦東;李慶鋒;宿志一;范建斌;史梓男;;復(fù)合絕緣子的人工加速老化試驗(yàn)[J];電網(wǎng)技術(shù);2006年12期
3 宿志一;李慶峰;;我國電網(wǎng)防污閃措施的回顧和總結(jié)[J];電網(wǎng)技術(shù);2010年12期
4 關(guān)志成,王紹武,梁曦東,王黎明,范炬;我國電力系統(tǒng)絕緣子污閃事故及其對策[J];高電壓技術(shù);2000年06期
5 王彬;梁曦東;張軼博;羅兵;李震宇;劉瑛巖;周遠(yuǎn)翔;;交、直流電壓下復(fù)合絕緣子和瓷絕緣子的自然積污試驗(yàn)[J];高電壓技術(shù);2009年09期
6 鄧鶴鳴;何正浩;許宇航;馬軍;李勁;;霧霾對沖擊放電路徑影響特性的分析[J];高電壓技術(shù);2009年11期
7 司馬文霞;李t熝,