600MW汽輪發(fā)電機(jī)組振動(dòng)問(wèn)題分析
發(fā)布時(shí)間:2018-03-25 19:49
本文選題:軸振 切入點(diǎn):瓦振 出處:《電站系統(tǒng)工程》2014年06期
【摘要】:汽輪發(fā)電機(jī)組振動(dòng)水平是考察機(jī)組運(yùn)行安全性和可靠性的重要指標(biāo)。汽輪發(fā)電機(jī)組的振動(dòng)問(wèn)題是機(jī)組制造質(zhì)量、安裝狀態(tài)、運(yùn)行條件的綜合反映。盡管引起機(jī)組振動(dòng)的原因錯(cuò)綜復(fù)雜,但相同類(lèi)型機(jī)組的振動(dòng)特性具有一定的相關(guān)性。收集同型機(jī)組的振動(dòng)特征對(duì)分析機(jī)組振動(dòng)具有借鑒作用。針對(duì)600 MW汽輪發(fā)電機(jī)組發(fā)生的典型工頻振動(dòng)故障進(jìn)行了分析,歸納了引起振動(dòng)的主要原因,并提出了應(yīng)對(duì)措施,為處理類(lèi)似振動(dòng)問(wèn)題提供指導(dǎo)和參考。
[Abstract]:The vibration level of turbine-generator set is an important index to evaluate the safety and reliability of the turbine generator set. The vibration problem of the turbine generator unit is the quality of the unit manufacture and the installation state. A comprehensive reflection of operating conditions. Although the causes of unit vibration are complex, But the vibration characteristics of the same type units have certain correlation. The collection of the vibration characteristics of the same type units is useful for the analysis of the unit vibration. The typical power frequency vibration faults of 600 MW turbogenerator units are analyzed. The main causes of vibration are summarized and the corresponding measures are put forward to provide guidance and reference for dealing with similar vibration problems.
【作者單位】: 東方汽輪機(jī)有限公司;環(huán)境保護(hù)部核與輻射安全中心;
【分類(lèi)號(hào)】:TM311
【參考文獻(xiàn)】
相關(guān)期刊論文 前4條
1 王延博;大型汽輪發(fā)電機(jī)組軸系不對(duì)中振動(dòng)的研究[J];動(dòng)力工程;2004年06期
2 司派友;;工作轉(zhuǎn)速下汽輪發(fā)電機(jī)轉(zhuǎn)子同相振動(dòng)故障分析[J];華北電力技術(shù);2006年03期
3 王詠梅;大型汽輪機(jī)摩擦振動(dòng)的故障特征分析[J];湖南電力;2003年01期
4 寇勝利;汽輪機(jī)膨脹不暢引起的振動(dòng)[J];汽輪機(jī)技術(shù);2004年06期
【共引文獻(xiàn)】
相關(guān)期刊論文 前10條
1 顏士偉;余世浩;;基于有限元模態(tài)技術(shù)的某電機(jī)轉(zhuǎn)子系統(tǒng)的共振分析[J];包裝與食品機(jī)械;2009年03期
2 田新啟;高N,
本文編號(hào):1664579