H橋逆變器IGBT開路故障診斷方法研究
發(fā)布時間:2018-02-01 22:29
本文關(guān)鍵詞: H橋逆變器 絕緣柵雙極型晶體管 核主成分分析 最小二乘支持向量機 故障診斷 出處:《電機與控制學報》2014年05期 論文類型:期刊論文
【摘要】:針對H橋結(jié)構(gòu)的逆變器中功率器件(insulated gate bipolar transistor,IGBT)開路故障的特點,提出了基于小波多分辨率分析、核主成分分析和最小二乘支持向量機的故障診斷方法。此方法選取半個基波周期的電容電壓平均值為原始信號,避免了負載變化對故障診斷的影響。首先利用小波多分辨率分析對原始信號進行多尺度分解提取出特征向量,然后利用核主成分分析方法來實現(xiàn)特征降維,最后建立了基于最小二乘支持向量機的故障分類器。在一臺660 V低壓靜止同步補償器試驗樣機上進行了試驗和分析,結(jié)果表明該方法具有良好的準確性和實時性。
[Abstract]:Aiming at the characteristics of open-circuit fault of H-bridge inverter with insulated gate bipolar transistors and IGBT. A fault diagnosis method based on wavelet multi-resolution analysis, kernel principal component analysis and least squares support vector machine is proposed, in which the average capacitance voltage of half fundamental period is chosen as the original signal. The influence of load change on fault diagnosis is avoided. Firstly, wavelet multi-resolution analysis is used to extract the eigenvector of the original signal, and then the kernel principal component analysis method is used to realize the feature dimension reduction. Finally, a fault classifier based on least squares support vector machine is established and tested and analyzed on a 660V low voltage static synchronous compensator test prototype. The results show that the method has good accuracy and real-time.
【作者單位】: 中國礦業(yè)大學信息與電氣工程學院;
【基金】:教育部高等學校博士學科點專項科研基金(20110095110014)
【分類號】:TM464
【正文快照】: 0引言近年來,基于H橋結(jié)構(gòu)的逆變器因其模塊化、易于安裝、擴展方便等優(yōu)點,在變頻調(diào)速、無功補償?shù)阮I(lǐng)域得到了廣泛應用。具有容錯控制能力的逆變器系統(tǒng)能通過及時診斷系統(tǒng)中的故障,并在故障后主動重構(gòu)系統(tǒng)的軟硬件結(jié)構(gòu),從而確保裝置在不損失性能指標或部分性能指標降低的情況下
【參考文獻】
相關(guān)期刊論文 前10條
1 彭文季;羅興,
本文編號:1483021