向家壩水電站機(jī)組低水頭過速試驗(yàn)導(dǎo)葉關(guān)閉規(guī)律異常分析
本文關(guān)鍵詞: 低水頭 過速試驗(yàn) 導(dǎo)葉關(guān)閉規(guī)律 反水泵工況 向家壩水電站 出處:《水力發(fā)電》2014年10期 論文類型:期刊論文
【摘要】:向家壩水電站的部分機(jī)組在低水頭進(jìn)行過速試驗(yàn)時(shí)出現(xiàn)了導(dǎo)葉關(guān)閉規(guī)律異常現(xiàn)象。通過實(shí)測(cè)數(shù)據(jù)和模型試驗(yàn)分析,機(jī)組在過速試驗(yàn)過程中接力器出現(xiàn)反向回開與反泵工況有關(guān)。機(jī)組在低水頭下進(jìn)行過速試驗(yàn),導(dǎo)葉小開度時(shí)進(jìn)入反水泵工況,導(dǎo)致導(dǎo)葉關(guān)閉規(guī)律出現(xiàn)異常。隨著運(yùn)行水頭的增大,該異,F(xiàn)象也隨之消失。
[Abstract]:Some units of Xiangjiaba Hydropower Station have abnormal phenomena of guide vane closure in the overspeed test at low water head. Based on the measured data and model test analysis. The reverse return of the relay is related to the reverse pump condition during the overspeed test. The unit carries on the overspeed test under the low water head and enters the reverse pump condition when the guide blade is small. It leads to the abnormal closure of the guide vane, and the abnormal phenomenon disappears with the increase of the running water head.
【作者單位】: 向家壩水力發(fā)電廠;
【分類號(hào)】:TV734
【正文快照】: 向家壩水電站共安裝8臺(tái)單機(jī)容量為800 MW的混流式水輪發(fā)電機(jī)組,其中右岸地下廠房和左岸壩后廠房各安裝4臺(tái)。首臺(tái)機(jī)組于2012年10月投產(chǎn)發(fā)電,2014年7月實(shí)現(xiàn)8臺(tái)機(jī)組全部投產(chǎn)發(fā)電。向家壩水電站設(shè)計(jì)運(yùn)行水位為370~380 m,水頭變幅為86.1~114.2 m,額定水頭100 m。根據(jù)水庫分期蓄水計(jì)
【參考文獻(xiàn)】
相關(guān)期刊論文 前2條
1 李彬;;水泵水輪機(jī)反水泵工況的特性研究[J];科技風(fēng);2012年14期
2 蔡軍;周喜軍;鄧?yán)?張文輝;;江蘇宜興抽水蓄能電站3號(hào)機(jī)組過速試驗(yàn)異常水擊現(xiàn)象的研究[J];水力發(fā)電;2009年02期
【共引文獻(xiàn)】
相關(guān)期刊論文 前10條
1 常近時(shí);;水輪機(jī)全特性曲線及其特征工況點(diǎn)的理論確定法[J];北京農(nóng)業(yè)工程大學(xué)學(xué)報(bào);1995年04期
2 白晶;;水輪機(jī)選型設(shè)計(jì)分析[J];科技創(chuàng)新與應(yīng)用;2012年04期
3 吳江;段利英;賓斌;廖一衡;譚韜宇;;水輪機(jī)工作密封壓力波動(dòng)缺陷處理[J];水電自動(dòng)化與大壩監(jiān)測(cè);2011年03期
4 肖良瑜;李永恒;;考慮預(yù)緊力的頂蓋與座環(huán)聯(lián)合受力研究[J];東方電氣評(píng)論;2011年02期
5 孫邦彥;;混流式水泵水輪機(jī)的轉(zhuǎn)速調(diào)節(jié)[J];東方電機(jī);1997年01期
6 馮建軍,羅興,
本文編號(hào):1464045