天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

當(dāng)前位置:主頁 > 科技論文 > 電氣論文 >

小電流接地系統(tǒng)故障選線與定位的研究

發(fā)布時間:2019-05-26 18:23
【摘要】:隨著經(jīng)濟(jì)的高速發(fā)展,電能作為清潔環(huán)保的二次能源改變著我們的生活。近些年來電力行業(yè)的發(fā)展突飛猛進(jìn),電網(wǎng)構(gòu)架復(fù)雜多變,裝機(jī)容量不斷增加,并且隨著特高壓輸電線路的全面建成,輸電線路在發(fā)生故障后,各行各業(yè)都會受到不同程度的影響。目前,我國的配電網(wǎng)廣泛采用小電流接地方式,當(dāng)該系統(tǒng)發(fā)生接地故障時,及時準(zhǔn)確選出故障線路是快速恢復(fù)供電的關(guān)鍵。本文分析了系統(tǒng)發(fā)生接地故障的特征,分別從穩(wěn)態(tài)特征和暫態(tài)特征方面深入研究。首先,詳細(xì)介紹基于穩(wěn)態(tài)分量和暫態(tài)分量的選線方法,如比幅比相法、五次諧波法、零序?qū)Ъ{法、能量法、小波分析法。通過仿真驗(yàn)證并總結(jié)每種選線方法的適用范圍和局限性,得出單一選線方法存在不足。針對單一選線無法實(shí)現(xiàn)適應(yīng)各種單相接地故障的情況,本文提出基于極限學(xué)習(xí)機(jī)的融合選線方法。首先在Matlab中建立110/35kV的小電流系統(tǒng)模型,用小波包變換算法提取特征分量。采用零序?qū)Ъ{法、自適應(yīng)陷波法、改進(jìn)鎖相環(huán)的五次諧波法分析在不同接地系統(tǒng)、不同接地電阻等故障類型發(fā)生故障時的暫態(tài)特征,利用極限學(xué)習(xí)機(jī)方法進(jìn)行融合選線,并與其他融合選線方法進(jìn)行對比。輸電網(wǎng)電壓等級越來越高,輸送容量也在不斷增加,輸電線路出現(xiàn)故障后,及時準(zhǔn)確的找到故障點(diǎn)不僅可以減輕運(yùn)檢人員的工作量,而且可以及時恢復(fù)線路供電。本文通過單端測距原理利用電壓反向行波實(shí)現(xiàn)定位,在Matlab中搭建小電流系統(tǒng)模型,利用Hear小波3層分解獲取電壓反向行波,通過大量數(shù)據(jù)可以驗(yàn)證該方法定位具有較高的準(zhǔn)確性,計算絕對誤差和相對誤差并歸納出現(xiàn)誤差的因素。
[Abstract]:With the rapid development of economy, electric energy, as a clean and environmentally friendly secondary energy, has changed our lives. In recent years, with the rapid development of the power industry, the power grid structure is complex and changeable, the installed capacity is increasing, and with the comprehensive completion of UHV transmission lines, transmission lines after failure, All kinds of industries will be affected to varying degrees. At present, the low current grounding mode is widely used in the distribution network of our country. When the grounding fault occurs in the system, the timely and accurate selection of the fault line is the key to the rapid recovery of power supply. In this paper, the characteristics of grounding fault in the system are analyzed, and the steady-state and transient characteristics are deeply studied. Firstly, the line selection methods based on steady and transient components, such as amplitude ratio phase method, fifth harmonic method, zero sequence admittance method, energy method and wavelet analysis method, are introduced in detail. Through simulation verification and summary of the applicable scope and limitations of each line selection method, it is concluded that the single line selection method has shortcomings. In view of the fact that a single line selection can not adapt to all kinds of single-phase grounding faults, a fusion line selection method based on limit learning machine is proposed in this paper. Firstly, the small current system model of 110/35kV is established in Matlab, and the feature components are extracted by wavelet packet transform algorithm. The zero sequence admittance method and adaptive notch method are used to analyze the transient characteristics of fault types in different grounding systems and different grounding resistance by improving the quintic harmonic method of phase-locked loop, and the limit learning machine method is used to fuse and select the line. It is compared with other fusion line selection methods. The voltage level of transmission network is getting higher and higher, and the transmission capacity is also increasing. After the fault of transmission line, finding the fault point in time can not only reduce the workload of operators, but also restore the power supply of the line in time. In this paper, based on the principle of single-terminal ranging, the voltage reverse traveling wave is realized by using the voltage reverse traveling wave, the small current system model is built in Matlab, and the voltage reverse traveling wave is obtained by using the three-layer decomposition of Hear wavelet. Through a large number of data, it can be verified that the method has high accuracy, calculates absolute error and relative error, and sums up the factors of error.
【學(xué)位授予單位】:太原科技大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2017
【分類號】:TM862

【參考文獻(xiàn)】

相關(guān)期刊論文 前10條

1 陳奎;陳博博;;基于改進(jìn)暫態(tài)相關(guān)分析和支持向量機(jī)的電弧故障選線研究[J];電力系統(tǒng)保護(hù)與控制;2016年24期

2 孟安波;葛佳菲;李德強(qiáng);翁子豪;焦夏楠;;基于縱橫交叉算法的神經(jīng)網(wǎng)絡(luò)配電網(wǎng)故障選線研究[J];電力系統(tǒng)保護(hù)與控制;2016年21期

3 宗偉林;許文強(qiáng);原亞雷;戴經(jīng)緯;皮杰;宋天寶;;礦井配電網(wǎng)單相接地故障選線與定位新方法[J];工礦自動化;2016年11期

4 馮孝宏;陳博博;儲亞男;陳奎;王愛東;;基于深度信息融合的小電流接地故障選線[J];電測與儀表;2016年20期

5 王磊;曹現(xiàn)峰;駱瑋;;基于GA優(yōu)化T-S模糊神經(jīng)網(wǎng)絡(luò)的小電流接地故障選線新方法[J];電測與儀表;2016年17期

6 梁睿;楊學(xué)君;彭楠;薛雪;程真何;沈興來;;基于廣域零序分布電壓特征的小電流接地選線方法[J];電網(wǎng)技術(shù);2016年10期

7 孫其東;張開如;劉建;伊利峰;宋祥民;李婭蕓;;基于五次諧波和小波重構(gòu)能量的配電網(wǎng)單相接地故障的選線方法研究[J];電測與儀表;2016年16期

8 張翠玲;李云路;;EMD及其能量變化曲線在小電流接地系統(tǒng)故障選線中的應(yīng)用[J];電測與儀表;2016年15期

9 譚杰;;基于Bayes判別分析的配電網(wǎng)故障選線方法[J];電力學(xué)報;2016年03期

10 魏萬華;吳正苗;;基于高頻暫態(tài)功率方向的單相接地故障選線技術(shù)研究[J];甘肅高師學(xué)報;2016年06期

相關(guān)會議論文 前1條

1 陳奎;程培波;;基于接地故障類型的綜合選線研究[A];第十七屆全國煤礦自動化學(xué)術(shù)年會、中國煤炭學(xué)會自動化專業(yè)委員會學(xué)術(shù)會議論文集[C];2007年

相關(guān)博士學(xué)位論文 前1條

1 龐清樂;基于智能算法的小電流接地故障選線研究[D];山東大學(xué);2007年

相關(guān)碩士學(xué)位論文 前10條

1 張耘川;基于HHT的小電流接地系統(tǒng)故障行波定位研究[D];蘭州交通大學(xué);2014年

2 汪敏;小波變換在輸電線路行波故障測距中的應(yīng)用[D];華北電力大學(xué);2014年

3 趙萬云;基于智能算法的小電流接地系統(tǒng)融合選線的研究[D];中國礦業(yè)大學(xué);2014年

4 韋曉廣;基于機(jī)器學(xué)習(xí)的小電流接地系統(tǒng)單相接地故障選線[D];中國礦業(yè)大學(xué);2014年

5 于正華;10kV電網(wǎng)小電流接地系統(tǒng)單相接地故障選線方法的研究[D];中國礦業(yè)大學(xué);2014年

6 盛怡;基于支持向量機(jī)的小電流接地系統(tǒng)故障選線研究[D];蘭州交通大學(xué);2013年

7 彭斌;小電流系統(tǒng)單相接地故障仿真與綜合選線研究[D];南昌大學(xué);2010年

8 王青;小電流接地系統(tǒng)單相接地故障的矢量融合與行波測距技術(shù)[D];湖南科技大學(xué);2010年

9 張文娟;基于小波分析的單相接地故障選線的研究與設(shè)計[D];山東大學(xué);2010年

10 馬延凱;基于小波分析的輸電線路行波故障測距的研究[D];山東大學(xué);2006年

,

本文編號:2485517

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/2485517.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶c6c97***提供,本站僅收錄摘要或目錄,作者需要刪除請E-mail郵箱bigeng88@qq.com