電阻應變電橋的激勵源對測試靈敏度的影響
發(fā)布時間:2018-11-02 20:39
【摘要】:【目的】隨著電阻應變片制造工藝的提高,電阻應變片不僅在稱量裝置中應用廣泛,在低功耗形變檢測系統(tǒng)中也應能得到應用。由此研究了在低電壓工作環(huán)境下電橋激勵源對測試靈敏度的影響。【方法】整個測試系統(tǒng)在3.3V的電壓下工作,在實驗中改變電橋的激勵電壓和激勵電流,將電橋輸出電壓經(jīng)高共模抑制比儀表放大器INA333放大后通過模數(shù)轉(zhuǎn)換器ADS1118采集后顯示。【結果】3V激勵電壓提高到5V激勵電壓時每克導致的輸出電壓變化幅度增加66.9%,激勵電流每增加1mA,輸出電壓靈敏度增加0.16。【結論】激勵電壓和激勵電流的增大有利于提高電橋輸出電壓,提高測試微小形變的靈敏度,降低后級數(shù)模轉(zhuǎn)換電路要求。
[Abstract]:[objective] with the improvement of resistance strain gauge manufacturing technology, resistive strain gauge is not only widely used in weighing device, but also can be used in low power deformation detection system. In this paper, the influence of bridge excitation source on test sensitivity in low voltage working environment is studied. [methods] the whole test system works at 3.3 V voltage, and the excitation voltage and current of the bridge are changed in the experiment. The output voltage of the bridge is amplified by the INA333 amplifier of the high common-mode rejection ratio instrument, and then displayed by the analog-to-digital converter ADS1118. [results] when the excitation voltage of 3V is increased to 5V, the amplitude of the output voltage change per gram is increased by 66.9%. The sensitivity of output voltage is increased by 0.16 for every 1 Ma of excitation current. [conclusion] the increase of excitation voltage and current is beneficial to increase the output voltage of bridge, improve the sensitivity of measuring small deformation, and reduce the requirement of digital to analog conversion circuit.
【作者單位】: 重慶師范大學物理與電子工程學院光電功能材料重慶市重點實驗室;
【基金】:國家自然科學基金(No.51507023) 重慶市科委項目(No.CSTC2016JCYJA0920) 重慶市基礎與前沿研究計劃項目(No.CSTC2014JCYJA70005)
【分類號】:TM938.4
本文編號:2306886
[Abstract]:[objective] with the improvement of resistance strain gauge manufacturing technology, resistive strain gauge is not only widely used in weighing device, but also can be used in low power deformation detection system. In this paper, the influence of bridge excitation source on test sensitivity in low voltage working environment is studied. [methods] the whole test system works at 3.3 V voltage, and the excitation voltage and current of the bridge are changed in the experiment. The output voltage of the bridge is amplified by the INA333 amplifier of the high common-mode rejection ratio instrument, and then displayed by the analog-to-digital converter ADS1118. [results] when the excitation voltage of 3V is increased to 5V, the amplitude of the output voltage change per gram is increased by 66.9%. The sensitivity of output voltage is increased by 0.16 for every 1 Ma of excitation current. [conclusion] the increase of excitation voltage and current is beneficial to increase the output voltage of bridge, improve the sensitivity of measuring small deformation, and reduce the requirement of digital to analog conversion circuit.
【作者單位】: 重慶師范大學物理與電子工程學院光電功能材料重慶市重點實驗室;
【基金】:國家自然科學基金(No.51507023) 重慶市科委項目(No.CSTC2016JCYJA0920) 重慶市基礎與前沿研究計劃項目(No.CSTC2014JCYJA70005)
【分類號】:TM938.4
【相似文獻】
相關期刊論文 前10條
1 ;農(nóng)機電測技術(二)[J];拖拉機;1975年01期
2 李明娣;焊接型電阻應變片簡介[J];中國設備管理;1996年04期
3 李壽松,李錦英;電阻應變片靈敏度的測量[J];物理實驗;1999年04期
4 高興勇,李子畢;用電阻應變片檢測電機主軸運行故障的方法[J];機電產(chǎn)品開發(fā)與創(chuàng)新;2004年04期
5 韓偉;;制作高溫電阻應變式稱重傳感器的生產(chǎn)工藝分析[J];科技創(chuàng)新與應用;2013年30期
6 高曉丁,胥光申,王錦;電阻應變片貼裝方位偏差對測量結果的影響[J];西安石油學院學報(自然科學版);2001年06期
7 李希勝,王紹純;電阻應變片信號的單回路差動測量[J];儀表技術;2000年01期
8 徐兵;崔富剛;舒慧霞;;一種超高值電阻的測量方法[J];黑龍江科技信息;2010年31期
9 陳剛;應變測量中集電器研究[J];研究與探索;1985年01期
10 耿皓,李建華;應力應變電測技術中影響測量誤差的主要因素分析[J];物流科技;2005年05期
相關碩士學位論文 前2條
1 苗玉剛;電阻應變片封裝用精密壓力加載設備設計[D];陜西理工學院;2015年
2 周哲;電阻應變片測量影響因素及熱機解耦研究[D];重慶大學;2012年
,本文編號:2306886
本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/2306886.html