城市電纜化率對配電網(wǎng)的中性點(diǎn)接地方式及故障特性影響的研究

發(fā)布時間:2018-10-08 06:42
【摘要】:配電網(wǎng)中性點(diǎn)的接地方式問題和很多方面都有著密切的關(guān)系,如供電可靠性,安全性,絕緣等問題。這些年來,配電網(wǎng)的電纜化率很大程度的升高,這使得網(wǎng)絡(luò)中的電容電流也隨之增加,間歇性弧光接地產(chǎn)生的故障比例增大,為了解決這些問題,提出對中性點(diǎn)接地方式進(jìn)行改進(jìn)。隨著新興接地方式的推出,新的問題也隨之產(chǎn)生。如何在現(xiàn)有情況下改進(jìn)單相接地故障模型,并提出更完善的接地方式是值得研究的問題。同時在研究實(shí)際工況時發(fā)現(xiàn),當(dāng)變壓器的中性點(diǎn)采用經(jīng)過間隙來接地時,負(fù)載存在的電動機(jī)在發(fā)生接地故障時,產(chǎn)生反饋?zhàn)饔?導(dǎo)致零序電壓增大且無法衰減到安全值,間隙保護(hù)動作,變壓器被切除,線路重合閘后,由于變壓器斷開,線路的正常運(yùn)行就會受到影響。本文針對變壓器的中性點(diǎn)如何接地的選擇又進(jìn)行了一定的研究。首先,在了解了現(xiàn)今存在的電弧模型的基礎(chǔ)上,對電纜化率較高的情況下發(fā)生頻率較高的間隙性電弧接地故障進(jìn)行數(shù)學(xué)模型的推導(dǎo)分析,進(jìn)一步改進(jìn),并使用仿真軟件進(jìn)行仿真分析驗(yàn)證,得到更完善的單相接地故障模型;其次,研究了現(xiàn)存的各種中性點(diǎn)接地方式的基礎(chǔ)上,在在電纜化率升高的情況下,分析每一種中性點(diǎn)接地方式存在的缺陷和不足,提出改進(jìn)的接地方式。并使用仿真分析軟件進(jìn)行處理分析,將第一步中所改進(jìn)的故障模型應(yīng)用到此處的線路中代替?zhèn)鹘y(tǒng)單相接地故障。最終得到一種改進(jìn)的接地方式,稱為消弧線圈分時段并聯(lián)電阻接地方式。在新的中性點(diǎn)接地方式下,研究原有接地方式的保護(hù)配置,找出不合理的地方,對繼電保護(hù)配置進(jìn)行完善;接著,本文又針對變壓器的中性點(diǎn)處的接地結(jié)構(gòu)進(jìn)行了分析,以實(shí)際配電網(wǎng)中出現(xiàn)的問題為出發(fā)點(diǎn),研究變壓器的間隙保護(hù),并研究電動機(jī)負(fù)荷的反饋?zhàn)饔脤ψ儔浩髦行渣c(diǎn)接地布局的影響,使用仿真軟件進(jìn)行分析,從負(fù)載的變化角度來研究變壓器中性點(diǎn)處電氣量,最終得出變壓器采用經(jīng)間隙接地的初步量化安全條件。
[Abstract]:The grounding mode of neutral point in distribution network is closely related to many aspects, such as power supply reliability, safety, insulation and so on. Over the years, the cable conversion rate of the distribution network has increased greatly, which makes the capacitance current in the network also increase, and the proportion of faults caused by intermittent arc grounding increases. In order to solve these problems, The improvement of neutral grounding mode is proposed. With the introduction of new grounding methods, new problems also arise. How to improve the single-phase grounding fault model and put forward a more perfect grounding mode is worth studying. At the same time, it is found that when the neutral point of transformer is grounded by gap, the motor with load has feedback effect when grounding fault occurs, which leads to the increase of zero-sequence voltage and the failure to attenuate to the safe value. Gap protection operation, the transformer is removed, the line reclosing, because the transformer is disconnected, the normal operation of the line will be affected. In this paper, how to select the neutral point of transformer is studied. First of all, on the basis of understanding the existing arc model, the mathematical model of the high frequency gap arc grounding fault with high cable conversion rate is deduced and analyzed, which is further improved. A more perfect single-phase grounding fault model is obtained by using the simulation software. Secondly, on the basis of the existing neutral grounding methods, under the condition of the increase of cable conversion rate, a more perfect single-phase grounding fault model is obtained. The defects and shortcomings of each neutral grounding method are analyzed, and an improved grounding method is proposed. The improved fault model in the first step is applied to replace the traditional single-phase grounding fault. Finally, an improved grounding method, called arc-suppression coil with parallel resistance in different periods, is obtained. Under the new neutral grounding mode, the protection configuration of the original grounding mode is studied, the unreasonable place is found out, and the relay protection configuration is improved. Then, the paper analyzes the earthing structure of the neutral point of the transformer. Based on the problems in the actual distribution network, the gap protection of transformer is studied, and the influence of motor load feedback on the neutral grounding layout of transformer is studied, and the simulation software is used to analyze it. From the point of view of load variation, the electrical quantity at the neutral point of transformer is studied, and the preliminary quantitative safety condition of transformer grounding through gap is obtained.
【學(xué)位授予單位】:華北電力大學(xué)(北京)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2017
【分類號】:TM862

【參考文獻(xiàn)】

相關(guān)期刊論文 前10條

1 劉渝根;許曉艷;馬晉佩;謝麗娜;;風(fēng)電場35kV電纜網(wǎng)絡(luò)中性點(diǎn)接地方式研究[J];電力系統(tǒng)保護(hù)與控制;2015年13期

2 許曄;郭謀發(fā);陳彬;楊耿杰;;配電網(wǎng)單相接地電弧建模及仿真分析研究[J];電力系統(tǒng)保護(hù)與控制;2015年07期

3 路紅偉;;淺談變壓器間隙保護(hù)措施[J];科技創(chuàng)業(yè)月刊;2015年03期

4 黃少鋒;鄭濤;;不同接地系統(tǒng)的單相接地故障統(tǒng)一分析方法[J];電氣電子教學(xué)學(xué)報;2013年02期

5 張有亮;閆志剛;趙燕妹;;主變壓器間隙保護(hù)與系統(tǒng)零序保護(hù)失配問題的解決措施探討[J];內(nèi)蒙古電力技術(shù);2012年04期

6 劉楠;張彥濤;秦曉輝;馬世英;唐曉駿;;感應(yīng)電動機(jī)負(fù)荷對短路電流影響機(jī)理研究[J];電網(wǎng)技術(shù);2012年08期

7 童奕賓;尤智文;李姝;;小電阻接地系統(tǒng)間歇性弧光過電壓分析[J];電力系統(tǒng)及其自動化學(xué)報;2012年03期

8 金海望;楊炳元;鄭日紅;夏永濤;;Matlab7.0下電弧模型的建立與分析[J];電氣技術(shù);2011年12期

9 于然;付周興;王清亮;王松波;孫尚斌;陳海東;;基于MATLAB的電弧建模仿真及故障分析[J];高壓電器;2011年09期

10 許慧一;王道剛;;大容量電動機(jī)反饋電流對10kV配電網(wǎng)的影響[J];電工電氣;2010年11期

相關(guān)博士學(xué)位論文 前1條

1 宋云東;電纜網(wǎng)運(yùn)行方式及故障控制的研究[D];沈陽工業(yè)大學(xué);2010年

相關(guān)碩士學(xué)位論文 前9條

1 恭秀芬;中壓配電網(wǎng)中性點(diǎn)接地方式研究與決策[D];重慶大學(xué);2014年

2 何林;中性點(diǎn)接地方式對配電網(wǎng)可靠性影響的研究[D];華北電力大學(xué);2013年

3 白挺瑋;中壓電纜電網(wǎng)運(yùn)行方式及故障模型仿真分析[D];昆明理工大學(xué);2012年

4 朱亮;10kV配電網(wǎng)小電阻接地系統(tǒng)單相短路故障及其保護(hù)研究[D];湖南大學(xué);2011年

5 周亮;小電阻接地系統(tǒng)間歇性電弧接地的仿真與研究[D];上海交通大學(xué);2011年

6 楊茂坤;全電纜貫通線合理接地方式與繼電保護(hù)配置研究[D];西南交通大學(xué);2010年

7 周卓敏;長沙城區(qū)10kV配網(wǎng)中性點(diǎn)接地方式的探討[D];湖南大學(xué);2007年

8 王輝;10kV配電網(wǎng)中性點(diǎn)接地方式的研究[D];天津大學(xué);2007年

9 李文鋒;新型主從式消弧線圈的研究[D];華北電力大學(xué)(北京);2004年

,