基于電能質(zhì)量監(jiān)測(cè)系統(tǒng)的智能電網(wǎng)故障定位研究
本文選題:故障定位 + 電能質(zhì)量監(jiān)測(cè)。 參考:《山東大學(xué)》2017年碩士論文
【摘要】:隨著全球能源互聯(lián)網(wǎng)大概念的提出,確定了電網(wǎng)智能化、全球化的發(fā)展方向,對(duì)電網(wǎng)電能品質(zhì)、可靠性、智能化提出了更高的要求。因此在現(xiàn)代智能電網(wǎng)的規(guī)劃和建設(shè)中,要將系統(tǒng)可靠性和電能質(zhì)量放到重要位置。智能電網(wǎng)其中主要的特征就是電能質(zhì)量監(jiān)測(cè)裝置的廣泛安裝以及由該系統(tǒng)獲得的大量實(shí)時(shí)現(xiàn)場(chǎng)數(shù)據(jù)。這使得電能質(zhì)量監(jiān)測(cè)系統(tǒng)(PowerQuality,PQ)成為與配電網(wǎng)數(shù)據(jù)采集與監(jiān)控系統(tǒng)(Distribution Supervisory Control and Data Acquisition,DSCADA)、廣域相量測(cè)量系統(tǒng)(Phasor Measurement Unit,PMU)、高級(jí)量測(cè)系統(tǒng)(Advanced Metering Infrastructure,AMI)并駕齊驅(qū)的電力系統(tǒng)監(jiān)測(cè)網(wǎng)絡(luò)。對(duì)這些數(shù)據(jù)所含信息進(jìn)行分析研究并加以挖掘利用,是近年來電能質(zhì)量領(lǐng)域發(fā)展的趨勢(shì)。本文將電能質(zhì)量參數(shù)應(yīng)用到故障定位上來,解決供電可靠性的問題,是對(duì)電能質(zhì)量監(jiān)測(cè)系統(tǒng)數(shù)據(jù)新應(yīng)用的一個(gè)大膽嘗試。本文首先介紹了傳統(tǒng)故障定位的方法,主要包括主動(dòng)式故障定位法和被動(dòng)式故障定位法,并對(duì)他們各自的優(yōu)缺點(diǎn)進(jìn)行了總結(jié)。從而對(duì)后文的故障定位的實(shí)現(xiàn),提供了參考和理論支持。然后對(duì)電能質(zhì)量各參數(shù)進(jìn)行詳細(xì)的介紹,同時(shí)推導(dǎo)出了電壓暫降檢測(cè)方法,并利用LabVIEW對(duì)電壓暫降信號(hào)生成、檢測(cè)分析。仿真結(jié)果證明了 dq分解法對(duì)電壓暫降檢測(cè)的有效性和準(zhǔn)確性,為后文利用電能質(zhì)量重要擾動(dòng)信息—電壓暫降幅值進(jìn)行故障定位提供了可靠的依據(jù)。接著為了充分利用電能質(zhì)量監(jiān)測(cè)系統(tǒng)數(shù)據(jù)資源,提出了基于電壓暫降幅值信息和故障距離分布函數(shù)的實(shí)用定位算法。首先通過線路參數(shù)構(gòu)建節(jié)點(diǎn)阻抗矩陣,再建立監(jiān)測(cè)點(diǎn)電壓關(guān)于故障距離的分布函數(shù)數(shù)據(jù)庫(kù),并且配置電壓暫降監(jiān)測(cè)點(diǎn)位置。然后建立測(cè)量參數(shù)矩陣。當(dāng)發(fā)生故障時(shí),通過建立監(jiān)測(cè)點(diǎn)狀態(tài)向量,可同時(shí)確定故障線路和相應(yīng)的故障距離,得出相應(yīng)的故障位置。此方法原理簡(jiǎn)單實(shí)用,不需要迭代計(jì)算,計(jì)算量小,能夠?qū)崿F(xiàn)實(shí)時(shí)的故障檢測(cè)與定位。最后通過MATLAB對(duì)一 10節(jié)點(diǎn)環(huán)狀配網(wǎng)系統(tǒng)進(jìn)行算例分析,最后驗(yàn)證了利用電壓暫降幅值信息進(jìn)行故障定位的有效性。最后本文通過LabVIEW平臺(tái)開發(fā)了具有電壓暫降檢測(cè)和電壓暫降源定位功能的電能質(zhì)量監(jiān)測(cè)系統(tǒng)及在線故障定位裝置。本文先從原理上介紹了該裝置的硬件構(gòu)成、電能質(zhì)量軟件構(gòu)成和故障定位的基本流程。最后通過LabVIEW實(shí)現(xiàn)了對(duì)各電能質(zhì)量參數(shù)的監(jiān)測(cè),同時(shí)實(shí)現(xiàn)了電壓暫降源的定位,為暫降責(zé)任量化提供了依據(jù);另外該系統(tǒng)實(shí)現(xiàn)了故障定位功能,為及時(shí)排除故障提供依據(jù)。本文只利用了電壓暫降的幅值信息,能實(shí)現(xiàn)故障點(diǎn)的定位,對(duì)于數(shù)據(jù)的同時(shí)性沒有要求,并且能夠有效利用已有裝置,實(shí)現(xiàn)構(gòu)建監(jiān)測(cè)網(wǎng)絡(luò)和故障定位系統(tǒng)的經(jīng)濟(jì)性。同時(shí)對(duì)電能質(zhì)量監(jiān)測(cè)系統(tǒng)其他數(shù)據(jù)資源的挖掘需要更加深入,對(duì)于故障定位的通信網(wǎng)絡(luò)構(gòu)建及數(shù)據(jù)傳輸格式還有待于進(jìn)一步的探索與研究。
[Abstract]:With the development of the global energy Internet concept, the intelligent power grid and the direction of globalization have been determined, and the power quality, reliability and intelligence of the power grid are higher. Therefore, in the planning and construction of modern smart grid, the system reliability and power quality should be put into an important position. The main features of the smart grid are the main features of the smart grid. It is the extensive installation of the power quality monitoring device and the large amount of real-time field data obtained by the system. This makes the PowerQuality (PQ) as the data acquisition and monitoring system of the distribution network (Distribution Supervisory Control and Data Acquisition, DSCADA), and the wide area phasor measurement system (Phasor Measurement) Unit, PMU), advanced measurement system (Advanced Metering Infrastructure, AMI) power system monitoring network. Analysis and exploitation of the information contained in these data is the trend of the development of the power quality field in recent years. In this paper, the power quality parameters are applied to the fault location to solve the reliability of power supply. The problem is a bold attempt at the new application of the data of the power quality monitoring system. This paper first introduces the traditional fault location method, mainly including the active fault location method and the passive fault location method, and summarizes their respective advantages and disadvantages, thus providing the reference and theory for the realization of the later fault location. And then the parameters of the power quality are introduced in detail, and the voltage sags detection method is derived, and the voltage sags signal is generated and analyzed by LabVIEW. The simulation results prove the validity and accuracy of the DQ decomposition method for the voltage sags detection, and the important disturbance information voltage sags are used in the later paper. The amplitude of the fault location provides a reliable basis. Then in order to make full use of the data resources of the power quality monitoring system, a practical location algorithm based on the voltage temporary drop value information and the fault distance distribution function is proposed. First, the node impedance matrix is constructed through the line parameters, and the distribution of the monitoring point voltage on the distribution of the fault distance is established. Function database, and configure the position of voltage sags monitoring point. And then establish the measurement parameter matrix. When the fault occurs, the fault line and the corresponding fault distance can be determined at the same time by establishing the state vector of the monitoring point, and the corresponding fault location can be obtained. This method is simple and practical, does not need iterative calculation, the calculation is small and can be real reality. In the end, the 10 node ring distribution network system is analyzed by MATLAB. Finally, the validity of the fault location is verified by using the voltage temporary drop value information. Finally, the power quality monitoring system with Voltage Sags Detection and voltage sags location function is developed through the LabVIEW platform. In this paper, the hardware structure of the device, the composition of the power quality software and the basic flow of the fault location are introduced in this paper. At last, the monitoring of the parameters of the power quality is realized by LabVIEW, and the location of the voltage sags is realized, and the basis for the temporary duty reduction is provided. In addition, the system is realized. The fault location function provides the basis for the timely elimination of the fault. This paper only uses the amplitude information of voltage sags, can realize the location of the fault point, does not require the data simultaneity, and can effectively use the existing equipment to realize the economy of the construction monitoring network and the fault location system. At the same time to the power quality monitoring system, the other Data mining needs to be deeper. The construction of communication network and data transmission format for fault location need further exploration and research.
【學(xué)位授予單位】:山東大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2017
【分類號(hào)】:TM76
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 韓云;徐學(xué)軍;馮曉良;胡森;;基于故障投報(bào)地理信息的配電網(wǎng)故障定位系統(tǒng)[J];供用電;2007年03期
2 施魯寧;;配電網(wǎng)快速故障定位系統(tǒng)[J];農(nóng)村電氣化;2009年04期
3 劉強(qiáng)強(qiáng);李巖松;楊以涵;于浩;齊超;;無接觸數(shù)據(jù)傳輸技術(shù)在配電網(wǎng)故障定位的應(yīng)用[J];電力系統(tǒng)保護(hù)與控制;2009年12期
4 蔡軍輝;;有關(guān)配電系統(tǒng)故障定位技術(shù)的研究[J];中小企業(yè)管理與科技(下旬刊);2009年10期
5 王昭楊;戚宇林;;配電網(wǎng)交流故障定位法的研究與實(shí)現(xiàn)[J];才智;2010年01期
6 宋如乾;靳彥儒;;混沌理論在故障定位中的應(yīng)用[J];電力科學(xué)與工程;2010年09期
7 王曉峰;洪彩涼;;一種基于數(shù)字無線通信的配電網(wǎng)故障定位系統(tǒng)的應(yīng)用[J];農(nóng)村電工;2013年03期
8 王哲明;02 新型多端單輸電線故障定位系統(tǒng)的開發(fā)[J];電力情報(bào);1995年04期
9 張曉友,賁洪奇,王立欣;一種多分支輸電線故障定位算法[J];哈爾濱工業(yè)大學(xué)學(xué)報(bào);1997年02期
10 張曉友,孫立山,賁洪奇,許承斌;多分支平行雙線輸電線故障定位算法的研究[J];中國(guó)電機(jī)工程學(xué)報(bào);1998年03期
相關(guān)會(huì)議論文 前10條
1 許童羽;楊濤;郭丹;;GIS平臺(tái)下故障投訴定位方法的研究與實(shí)現(xiàn)[A];中國(guó)高等學(xué)校電力系統(tǒng)及其自動(dòng)化專業(yè)第二十四屆學(xué)術(shù)年會(huì)論文集(下冊(cè))[C];2008年
2 楊雋;;玉溪配電網(wǎng)故障定位系統(tǒng)研究及智能故障定位終端設(shè)計(jì)[A];2012年云南電力技術(shù)論壇論文集(文摘部分)[C];2012年
3 呂虎;;基于模式理論的T型線路的故障定位算法[A];全面建設(shè)小康社會(huì):中國(guó)科技工作者的歷史責(zé)任——中國(guó)科協(xié)2003年學(xué)術(shù)年會(huì)論文集(上)[C];2003年
4 雷昱;;淺析故障定位的“三步驟法”[A];武漢市首屆學(xué)術(shù)年會(huì)通信學(xué)會(huì)2004年學(xué)術(shù)年會(huì)論文集[C];2004年
5 趙玉忠;胡少?gòu)?qiáng);;基于遺傳算法的配電網(wǎng)故障定位[A];中國(guó)高等學(xué)校電力系統(tǒng)及其自動(dòng)化專業(yè)第二十四屆學(xué)術(shù)年會(huì)論文集(中冊(cè))[C];2008年
6 劉總平;;配電自動(dòng)化故障定位的一種新方法[A];第一屆電器裝備及其智能化學(xué)術(shù)會(huì)議論文集[C];2007年
7 惠慧;金玉生;;配電網(wǎng)故障定位的改進(jìn)通用矩陣算法[A];中國(guó)高等學(xué)校電力系統(tǒng)及其自動(dòng)化專業(yè)第二十四屆學(xué)術(shù)年會(huì)論文集(上冊(cè))[C];2008年
8 潘雅佳;;10KV配電網(wǎng)中性點(diǎn)不接地系統(tǒng)故障定位研究[A];2009年云南電力技術(shù)論壇論文集(文摘部分)[C];2009年
9 李彬;閆峰;朱建華;;指針調(diào)整的故障定位[A];湖北省通信學(xué)會(huì)、武漢通信學(xué)會(huì)2009年學(xué)術(shù)年會(huì)論文集[C];2009年
10 張暉生;紀(jì)彩峰;;電力光纜故障處理及維護(hù)方法[A];山東電機(jī)工程學(xué)會(huì)第四屆供電專業(yè)學(xué)術(shù)交流會(huì)論文集[C];2007年
相關(guān)重要報(bào)紙文章 前6條
1 李偉新 辜明嫻;故障定位、隔離與復(fù)電時(shí)間縮至“秒”級(jí)[N];國(guó)家電網(wǎng)報(bào);2013年
2 中國(guó)電信股份有限公司上海研究院 李莉;精確化故障定位提升網(wǎng)維水平[N];人民郵電;2008年
3 湖北興山天星供電有限公司 蔡文彬;以GPS提升線路管理科技含量[N];中國(guó)電力報(bào);2009年
4 本報(bào)記者 鄢雁華 見習(xí)記者 馬俊婭 通訊員 王兵 王娜;故障定位裝置:大幅減少配網(wǎng)故障查找時(shí)間[N];中國(guó)電力報(bào);2014年
5 本報(bào)記者 胡英;定位網(wǎng)絡(luò)故障[N];計(jì)算機(jī)世界;2004年
6 李冰 趙立強(qiáng);中國(guó)電科院兩項(xiàng)目通過驗(yàn)收[N];國(guó)家電網(wǎng)報(bào);2011年
相關(guān)博士學(xué)位論文 前2條
1 張成;增值業(yè)務(wù)的概率故障定位[D];北京郵電大學(xué);2010年
2 林景棟;配電網(wǎng)故障定位和負(fù)荷均衡的圖算法[D];重慶大學(xué);2002年
相關(guān)碩士學(xué)位論文 前10條
1 靳盤龍;配電網(wǎng)故障定位的研究[D];天津理工大學(xué);2015年
2 闞菲菲;配電網(wǎng)故障定位與恢復(fù)算法研究[D];南京師范大學(xué);2015年
3 宋揚(yáng);配網(wǎng)故障定位系統(tǒng)建設(shè)與監(jiān)控主站軟件設(shè)計(jì)與實(shí)現(xiàn)[D];電子科技大學(xué);2015年
4 王敏;基于行波原理的10kV電纜單環(huán)網(wǎng)在線故障定位技術(shù)研究[D];山東理工大學(xué);2012年
5 高洪梅;基于電流相位差動(dòng)原理的有源配電網(wǎng)饋線故障定位新方法[D];山東理工大學(xué);2012年
6 張威;10kV配電網(wǎng)行波故障定位方案研究[D];山東理工大學(xué);2015年
7 王建鵬;10kV配電網(wǎng)故障定位統(tǒng)一矩陣算法研究[D];山東理工大學(xué);2015年
8 張濤;城市配電線路狀態(tài)參數(shù)的在線監(jiān)測(cè)與故障定位方法研究[D];河北工業(yè)大學(xué);2015年
9 王文平;配電線路設(shè)備故障定位及搶修調(diào)度系統(tǒng)的研發(fā)[D];華北電力大學(xué);2015年
10 應(yīng)璐曼;基于WAMS的PMU優(yōu)化配置和故障定位方案研究[D];華北電力大學(xué);2015年
,本文編號(hào):1905556