天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

當前位置:主頁 > 科技論文 > 電氣論文 >

核電廠消防水泵管道振動問題分析及應對措施研究

發(fā)布時間:2018-01-26 20:20

  本文關鍵詞: 核電 消防水泵 回流管線 超壓 振動 出處:《給水排水》2017年S2期  論文類型:期刊論文


【摘要】:消防水泵流量和揚程設計一般均按最不利點最大流量和揚程進行選型。大部分火災在初期可能就被滅火系統(tǒng)撲滅,實際火災初期時只需要很小的流量,必然會存在小流量工況點。消防泵在小流量工況點運行時可能造成部分管道超壓振動,合理的預測和消除消防水泵管道振動問題及采取有效措施,可以保護消防系統(tǒng)有效地運行。該問題處理適用于類似問題的應用借鑒。
[Abstract]:The design of flow and head of fire water pump is usually based on the maximum flow and head of the most disadvantageous point. Most of the fires may be extinguished by the fire extinguishing system in the initial stage, but only a very small flow rate is needed in the early stage of the fire. It is inevitable that there will be a small flow rate operating point. The fire pump may cause part of the pipeline overpressure vibration when operating at the small flow condition. The reasonable prediction and elimination of the fire pump pipeline vibration problems and effective measures are taken. It can protect the fire fighting system from running effectively. The problem handling is applicable to the application of similar problems.
【作者單位】: 深圳中廣核工程設計有限公司;
【分類號】:TM623
【正文快照】: 0 前言核電廠消防水生產(chǎn)系統(tǒng)(JPP)的功能是向核島廠房、常規(guī)島廠房和廠內其它區(qū)域提供一定壓力的消防水。消防水泵流量和揚程設計一般均按最不利點火災,按規(guī)范設計,進行流量和揚程的選擇,消防水泵按最大流量和揚程進行選型。由于大部分火災在初期可能就被撲滅,實際火災時可能

【相似文獻】

相關期刊論文 前3條

1 袁少波;喻丹萍;周正平;席志德;趙暉;何超;;田灣核電站管道振動問題處理[J];核動力工程;2012年06期

2 康豫軍;安付立;衛(wèi)大為;王軍民;董雷;王必寧;吳曉俊;蔣建輝;;電站管道振動分析與治理[J];熱力發(fā)電;2011年06期

3 梁小燕,趙玉成;給水管道振動信號的小波分析及消振研究[J];中國安全科學學報;2005年02期

相關碩士學位論文 前1條

1 祝春艷;核電用消防水泵的抗震安全及內流場分析[D];北京化工大學;2009年

,

本文編號:1466497

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/1466497.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權申明:資料由用戶c24e8***提供,本站僅收錄摘要或目錄,作者需要刪除請E-mail郵箱bigeng88@qq.com