基于PSASP的電力系統(tǒng)保護建模分析
本文關(guān)鍵詞:基于PSASP的電力系統(tǒng)保護建模分析 出處:《合肥工業(yè)大學》2016年碩士論文 論文類型:學位論文
更多相關(guān)文章: 保護建模 PSASP 隱性故障 Markov 整定值優(yōu)化
【摘要】:繼電保護是電力系統(tǒng)的重要組成部分,其作用已經(jīng)不僅僅局限于快速切除故障元件,它在保證整個電網(wǎng)系統(tǒng)安全穩(wěn)定運行方面起著越來越重要的作用。不論剖析電力系統(tǒng)事故發(fā)生的原因及其過程,還是分析電力系統(tǒng)較長時間內(nèi)動態(tài)過程的穩(wěn)定性問題,保護的動態(tài)特性都是不容忽視的。所以利用電力系統(tǒng)動態(tài)仿真程序?qū)^電保護的動作過程進行模擬,進而分析電力系統(tǒng)的全過程穩(wěn)定特性,對避免發(fā)生大面積停電事故及研究防止事故擴大的有效措施等都具有重要意義。本文首先對繼電保護系統(tǒng)進行深入研究,針對目前電力系統(tǒng)仿真軟件中保護模型不完善的問題,以電力系統(tǒng)輸電線的保護為主要研究對象,利用電力系統(tǒng)分析綜合程序(PSASP)的用戶自定義模塊針對電流保護、距離保護等多種類型保護原理進行了建模仿真,并以IEEE-39及WEPRI-11系統(tǒng)為算例,驗證了搭建模型和采用方法的有效性;然后,分析了隱性故障產(chǎn)生的原因和特點,并針對三段式距離保護由于整定值引起的繼電保護隱性故障進行詳細的分析,進而針對幾種保護隱性故障模式引起的拒動誤動情況進行了仿真分析:最后,基于Markov狀態(tài)空間法,針對高壓系統(tǒng)兩套主保護及遠近后備保護,建立詳細的線路-保護狀態(tài)轉(zhuǎn)移模型,計算由于整定值隱性故障引起的誤動概率與拒動概率,并以此給出了一種整定值的優(yōu)化方法,算例仿真驗證了該方法的有效性。
[Abstract]:The relay protection is an important part of power system, its role is not limited to the rapid removal of faulty components, to ensure it plays an increasingly important role in the safe and stable operation of the entire power system. Regardless of causes of power system accidents and analysis process, or stability of the dynamic process of a long time in power system, dynamic the characteristics of protection can not be ignored. So the action process of relay protection simulation program for power system dynamic simulation and analysis of the whole process of stability characteristics of power system, is of great significance to avoid blackouts accident and prevent the accident of the effective measures. Firstly, in-depth research on relay protection in view of the current system, power system simulation software protection model problems in power system, transmission line Protection as the main research object, by power system analysis software package (PSASP) custom module for current protection, distance protection and other types of protection principle of modeling and simulation, and the IEEE-39 and WEPRI-11 system for example, the model was set up and used to verify the validity of the method; then, analyzes the causes and characteristics the hidden fault generated, and for the three phase distance protection setting value because of hidden failures of relay protection caused by the detailed analysis of the dynamic malfunction in the simulation analysis to according to the failure mode caused by several kinds of implicit protection: finally, the Markov based on the state space method, the high voltage system of two sets of main protection and distance backup protection, the establishment of detailed line protection state transition model, setting value calculation due to recessive failure caused by misoperation probability and rejection probability, and thus give a setting The effectiveness of the method is verified by an example simulation.
【學位授予單位】:合肥工業(yè)大學
【學位級別】:碩士
【學位授予年份】:2016
【分類號】:TM77;TM743
【參考文獻】
相關(guān)期刊論文 前10條
1 趙麗莉;李雪明;倪明;程雅夢;;繼電保護與安全穩(wěn)定控制系統(tǒng)隱性故障研究綜述及展望[J];電力系統(tǒng)自動化;2014年22期
2 徐得超;劉巍;朱旭凱;夏天;朱全勝;徐樹文;陳德?lián)P;;含大量繼保和安自裝置的連鎖故障并行仿真軟件研發(fā)[J];電力系統(tǒng)保護與控制;2014年21期
3 李博通;李永麗;姚創(chuàng);李仲青;;繼電保護系統(tǒng)隱性故障研究綜述[J];電力系統(tǒng)及其自動化學報;2014年07期
4 薛安成;羅麟;景琦;曹小拐;畢天姝;黃少鋒;;基于Markov模型的高壓輸電線繼電保護裝置風險評估[J];電網(wǎng)技術(shù);2014年07期
5 夏添;;繼電保護隱性故障中的電力系統(tǒng)連鎖故障研究[J];廣東科技;2014年12期
6 趙曉楠;于群;;基于VB平臺的Simulink電力系統(tǒng)繼電保護仿真[J];電氣傳動自動化;2012年06期
7 薛安成;王睿琛;王寶;畢天姝;黃少鋒;;基于單位生命周期費用最小的繼電保護裝置更換策略[J];電力系統(tǒng)自動化;2013年05期
8 方勇杰;;美國“9·8”大停電對連鎖故障防控技術(shù)的啟示[J];電力系統(tǒng)自動化;2012年15期
9 戴志輝;王增平;焦彥軍;曹樹江;;階段式保護原理性失效風險的概率評估方法[J];電工技術(shù)學報;2012年06期
10 王睿琛;薛安成;畢天姝;黃少鋒;;繼電保護裝置時變失效率估算及其區(qū)域性差異分析[J];電力系統(tǒng)自動化;2012年05期
,本文編號:1422698
本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/1422698.html