核電廠寒冷廠址防冰設(shè)計(jì)
發(fā)布時(shí)間:2018-01-13 20:30
本文關(guān)鍵詞:核電廠寒冷廠址防冰設(shè)計(jì) 出處:《給水排水》2017年S2期 論文類型:期刊論文
更多相關(guān)文章: 核電廠 浮冰 導(dǎo)流堤 下潛深度
【摘要】:紅沿河核電廠取水口防冰設(shè)計(jì)中采用導(dǎo)流以及底部取水工程措施,有效解除了浮冰下潛堵塞取水通道的威脅,保障了電廠的安全運(yùn)行。設(shè)計(jì)過程中采取通過物模試驗(yàn)的方式,形成完整的設(shè)計(jì)驗(yàn)證,同時(shí)核電廠取水口運(yùn)行良好,進(jìn)一步佐證取水口防冰設(shè)計(jì)的合理性。
[Abstract]:In the ice prevention design of the intake port of Hongyan River nuclear power plant, the engineering measures of diversion and bottom water intake are adopted, which effectively relieves the threat of ice floatation and submersible blocking of the water intake channel. The safety operation of the power plant is ensured. The complete design verification is formed by the method of physical model test in the design process, and the water intake of the nuclear power plant runs well, which further proves the rationality of the ice prevention design of the intake port.
【作者單位】: 深圳中廣核工程設(shè)計(jì)有限公司;
【分類號(hào)】:TM623.1
【正文快照】: 1 背景介紹紅沿河廠址地處遼東灣西海岸位于寒冷地區(qū),是我國緯度最高的核電廠。廠址近岸固定冰較少,主要是每年入冬后會(huì)有大量浮冰從遼東灣北部順洋流往南漂移。從往年海洋局發(fā)布的海冰警報(bào)示意圖看,紅沿河廠址處于海上浮冰影響范圍,浮冰最大厚度可達(dá)1m,但較少出現(xiàn)冰層大量層,