本文選題:擴散器結(jié)構(gòu) 切入點:局部阻力 出處:《中國安全生產(chǎn)科學(xué)技術(shù)》2016年09期 論文類型:期刊論文
【摘要】:在大主扇通風(fēng)系統(tǒng)中多采用低壓大流量風(fēng)機,在風(fēng)機出風(fēng)段多安裝擴散器,主要作用是降低出口動壓提高風(fēng)機靜壓而達(dá)到回收出風(fēng)口斷面動能的效果。重點分析風(fēng)流在流經(jīng)不同結(jié)構(gòu)擴散器時的流場以及出口的動能損失,敘述了紊流過程中產(chǎn)生阻力的原因,實驗測定風(fēng)流在擴散器后的靜壓和出口斷面的速度。通過數(shù)值模擬和實驗證明:流線型擴散器局部阻力較小,且具有較高的動能回收率和擴散器效率。結(jié)果表明此內(nèi)容研究對研究擴散器的最優(yōu)設(shè)計參數(shù)和通風(fēng)節(jié)能具有一定的指導(dǎo)作用。
[Abstract]:In the ventilation system of large main fan, low pressure and large flow fan are often used, and diffusers are installed in the fan outlet section. The main function is to reduce the outlet dynamic pressure and increase the static pressure of the fan to achieve the effect of recovering the kinetic energy of the air outlet section. The flow field and the loss of kinetic energy at the outlet of the air flow through diffusers with different structures are analyzed emphatically. The causes of resistance in turbulent flow are described. The static pressure behind diffuser and the velocity of outlet section are measured experimentally. It is proved by numerical simulation and experiment that the local resistance of streamline diffuser is small. The results show that this research can be used to study the optimal design parameters of diffuser and ventilation energy saving.
【作者單位】: 內(nèi)蒙古科技大學(xué)礦業(yè)研究院;
【基金】:國家自然科學(xué)基金項目(51064018)
【分類號】:TD724
【相似文獻(xiàn)】
相關(guān)期刊論文 前8條
1 潘軍義,董振民;多級機站通風(fēng)局部阻力的研究[J];金屬礦山;2001年09期
2 ;用電模擬儀器計算通風(fēng)網(wǎng)路與局部阻力[J];川煤科技;1974年02期
3 段在鵬;謝賢平;毛艷麗;;關(guān)于局部阻力與正面阻力較大井巷通風(fēng)的熱力計算分析[J];云南冶金;2011年01期
4 李雨林;程厲生;李高祺;;降低井下機站的局部阻力及機站合理結(jié)構(gòu)的研究[J];金屬礦山;1988年07期
5 張齊堯;井巷通風(fēng)局部阻力小議[J];煤礦安全;1982年05期
6 劉琛;彭世超;陳立;;降低直角拐彎風(fēng)井局部阻力的Fluent模擬[J];煤炭與化工;2014年02期
7 高建良,樊小利,范俊嶺,姚延廷;梯形巷道兩道調(diào)節(jié)風(fēng)窗局部阻力的實驗研究[J];煤礦安全;1995年06期
8 ;[J];;年期
,本文編號:1642623
本文鏈接:http://sikaile.net/kejilunwen/anquangongcheng/1642623.html
最近更新
教材專著