核電站立式泵組結(jié)構(gòu)共振分析與防治研究
本文選題:核電廠用泵 切入點:立式泵 出處:《水泵技術(shù)》2017年03期
【摘要】:基于核電站立式泵組的結(jié)構(gòu)及安裝特點,分析了其在現(xiàn)場頻繁發(fā)生結(jié)構(gòu)共振故障的原因及結(jié)構(gòu)共振源的判斷方法。結(jié)合核電站現(xiàn)場立式泵共振故障的分析與診斷方法,對立式泵組通過改變固有頻率及現(xiàn)場動平衡來解決結(jié)構(gòu)共振問題的思路與方法進行了研究,為此類轉(zhuǎn)動設(shè)備的故障診斷提供了重要依據(jù)。
[Abstract]:Based on the structure and installation characteristics of the vertical pump set in nuclear power plant, the causes of frequent structural resonance faults and the method of judging the structural resonance source are analyzed.Combined with the analysis and diagnosis method of the resonance fault of the nuclear power station vertical pump, the train of thought and method of solving the structural resonance problem by changing the natural frequency and the field dynamic balance of the opposing pump group are studied.It provides an important basis for fault diagnosis of this kind of rotating equipment.
【作者單位】: 中廣核工程有限公司設(shè)備采購與成套中心;
【分類號】:TH38;TM623