基于不平衡系數(shù)對熱短路抑制措施的研究
發(fā)布時間:2018-02-17 07:42
本文關(guān)鍵詞: 地源熱泵 熱響應(yīng)實驗 分布式光纖 熱短路現(xiàn)象 數(shù)值模擬 出處:《建筑科學(xué)》2016年12期 論文類型:期刊論文
【摘要】:本文通過熱響應(yīng)實驗,驗證了FLUENT所建立三維非穩(wěn)態(tài)地埋管系統(tǒng)的數(shù)值模型。在所建模型上,通過熱短路不平衡系數(shù)定量分析了不同回填材料和流速對地埋管熱短路現(xiàn)象的影響。根據(jù)熱短路現(xiàn)象的強弱,針對3種代表性工況對隔板式地埋管換熱器進行了模擬研究。研究結(jié)果表明:隔熱板作為熱短路現(xiàn)象的抑制措施對不同工況下的系統(tǒng)換熱量的影響有較大差異。
[Abstract]:In this paper, the numerical model of 3D unsteady buried pipe system established by FLUENT is verified by the thermal response experiment. The influence of different backfill materials and flow rate on the thermal short-circuit phenomenon of buried pipes is quantitatively analyzed by the thermal short-circuit imbalance coefficient. In this paper, the heat exchanger of the diaphragm type ground buried tube is simulated under three typical working conditions. The results show that the heat transfer of the system under different working conditions is influenced greatly by the heat insulation board as the suppression measure of the hot short circuit phenomenon.
【作者單位】: 內(nèi)蒙古科技大學(xué)能源與環(huán)境學(xué)院;北京華清榮昊新能源開發(fā)有限責(zé)任公司;內(nèi)蒙古自治區(qū)白云鄂博礦多金屬資源綜合利用重點實驗室;
【基金】:內(nèi)蒙古自治區(qū)自然科學(xué)基金資助項目“內(nèi)蒙地區(qū)太陽能-土壤源熱泵耦合系統(tǒng)運行特性研究”(2014MS0530);內(nèi)蒙古自治區(qū)自然科學(xué)基金資助項目“基于地下水滲流的復(fù)雜土壤結(jié)構(gòu)熱物性參數(shù)計算模型研究”(2015MS0561)
【分類號】:TU83