既有供熱系統(tǒng)改擴建方法研究
[Abstract]:With the development of urbanization in our country, people's demand for heat supply is increasing gradually. The newly-built heating system not only covers a large area, but also has huge investment and difficult economic recovery. In view of the primary network transformation method of the heating network, this paper mainly studies the related problems of the application of the distributed water pump system in the annular heating system. Firstly, it analyzes the economy of the heating system and establishes the economic model of the universality. The pressure distribution of each pipe section in the heat pipe network is expressed by the average specific friction. Based on the universal economic model, the economic model for the distributed pump system in the annular pipe network is established. The formula for calculating the economic specific friction is derived. Secondly, the characteristics of the distributed pump system in the annular pipe network are studied, mainly aiming at the zero in the system. Based on the model and engineering case, the economic specific frictional resistance formula is used to analyze the new ring system project and verify the economy of the economic specific frictional resistance. According to the renovation project of a heating system in Harbin and based on the renovation design process of the existing pipe network, the renovation method of applying distributed water pump system to the loop pipe network in the actual project is explained. The definition, system form and pipe network form of the system are given. Secondly, the restriction conditions of the series single pipe reformation system are studied, and the method of maximum extension calculation is obtained. Finally, according to the specific case, combined with the economic model of heating system, the economic efficiency of the traditional transformation mode and the series single-pipe system transformation mode is compared, and the influence of the connection location between the new heating load area and the new users on the economic efficiency of the system transformation is considered respectively, and the characteristics of this transformation mode are obtained. The way of design and research provides a theoretical basis and decision-making basis for practical projects.
【學(xué)位授予單位】:哈爾濱工業(yè)大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2017
【分類號】:TU995
【參考文獻】
相關(guān)期刊論文 前10條
1 那海濤;方修睦;;分布式水泵系統(tǒng)和傳統(tǒng)方式在某區(qū)域熱源應(yīng)用對比分析研討[J];應(yīng)用能源技術(shù);2015年09期
2 尹榮杰;;分布式變頻泵供熱系統(tǒng)的運行調(diào)節(jié)方式[J];區(qū)域供熱;2015年01期
3 王中華;楊濤;;基于遺傳算法的區(qū)域供冷供熱管網(wǎng)優(yōu)化設(shè)計方法的改進研究[J];建筑節(jié)能;2014年06期
4 石兆玉;楊同球;;全網(wǎng)分布式輸配供熱系統(tǒng)的優(yōu)越性[J];區(qū)域供熱;2013年04期
5 趙曉靖;;不同的熱源供熱溫度在多熱源聯(lián)網(wǎng)系統(tǒng)中的應(yīng)用與探討[J];區(qū)域供熱;2013年01期
6 王春玲;;集中供熱的現(xiàn)狀及發(fā)展趨勢[J];林業(yè)科技情報;2012年03期
7 王云琦;;吸收式熱泵機組在城市集中熱網(wǎng)應(yīng)用的適應(yīng)性分析[J];區(qū)域供熱;2012年02期
8 王們;鄒平華;雷翠紅;;分布式水泵供熱系統(tǒng)零壓差點與輸送功率的關(guān)系[J];暖通空調(diào);2011年10期
9 白振宇;段立豐;王磊;孫剛;;分布式循環(huán)水泵供暖系統(tǒng)的設(shè)計[J];區(qū)域供熱;2010年04期
10 姚東文;邱林;;分布式變頻泵供熱系統(tǒng)節(jié)能影響因素[J];煤氣與熱力;2010年04期
相關(guān)博士學(xué)位論文 前1條
1 王海超;多熱源聯(lián)合供熱系統(tǒng)調(diào)峰方式及綜合優(yōu)化研究[D];哈爾濱工業(yè)大學(xué);2013年
相關(guān)碩士學(xué)位論文 前10條
1 李振遠;單向環(huán)主干線熱水供熱管網(wǎng)調(diào)節(jié)方式的研究[D];哈爾濱工業(yè)大學(xué);2016年
2 林愛玲;雙熱源單向環(huán)狀供熱管網(wǎng)運行調(diào)節(jié)與調(diào)度研究[D];哈爾濱工業(yè)大學(xué);2015年
3 田野;區(qū)域供熱系統(tǒng)聯(lián)絡(luò)方式和多熱源位置優(yōu)化的研究[D];哈爾濱工業(yè)大學(xué);2015年
4 李秋華;供熱管網(wǎng)熱力可及性及單向環(huán)供熱系統(tǒng)相關(guān)問題研究[D];哈爾濱工業(yè)大學(xué);2014年
5 武磊;單向環(huán)主干線管網(wǎng)供熱系統(tǒng)的可靠性研究[D];哈爾濱工業(yè)大學(xué);2014年
6 高光洋;分布式熱水集中供熱系統(tǒng)水力特性分析及運行調(diào)節(jié)[D];山東建筑大學(xué);2014年
7 季明星;熱水供熱梯級混水系統(tǒng)的研究[D];哈爾濱工業(yè)大學(xué);2012年
8 雒俐暖;單管供熱系統(tǒng)及其應(yīng)用研究[D];太原理工大學(xué);2012年
9 馬琳;多熱源環(huán)狀管網(wǎng)定壓及運行調(diào)節(jié)的研究[D];長安大學(xué);2011年
10 張志雄;單管混水直接供熱系統(tǒng)設(shè)計方法的研究[D];太原理工大學(xué);2010年
,本文編號:2232338
本文鏈接:http://sikaile.net/jianzhugongchenglunwen/2232338.html