薄鋼板PEC柱-削弱截面鋼梁框架層間抗震試驗研究
本文選題:薄鋼板組合截面PEC柱 + 削弱梁截面 ; 參考:《西南交通大學學報》2017年04期
【摘要】:為研究薄鋼板組合PEC柱(強軸)-削弱截面鋼梁組合框架的層間抗震性能,設計制作1榀組合框架中間層子結構1∶2縮尺試件并對其進行水平循環(huán)往復荷載抗震試驗.基于試驗現(xiàn)象和測試數(shù)據(jù)整理,得到了試件破壞模式與滯回特征曲線,并對試件水平抗側剛度、耗能性能和變形模式等進行了分析.研究結果顯示:采用梁端截面削弱方式可通過梁端塑性鉸形成位置偏離節(jié)點區(qū)以滿足"強節(jié)點"的抗震要求;試件整體與層間中間層位移延性系數(shù)分別大于4.05和4.81,對應等效粘滯阻尼比最大值分別為0.288和0.286;試件結構水平抗側剛度沿高度均勻分布,側移變形呈理想倒三角彎剪型側移變形模式;試件結構破壞模式為梁端削弱截面充分屈服形成塑性鉸的理想塑性破壞機構,且其承載力下降到極限承載力85%時,對應試件整體與層間側移角分別為0.043 3 rad和0.039 4 rad,相應超過框架結構大震層間側移限值0.035 0 rad,說明試件結構具有良好的抗震延性.
[Abstract]:In order to study the interstory seismic behavior of PEC column (strong axis) and steel beam composite frame with thin steel plate, a substructure of composite frame with intermediate story at 1:2 scale was designed and fabricated and tested by horizontal cyclic reciprocating load. Based on the experimental phenomena and test data, the failure mode and hysteretic characteristic curve were obtained, and the horizontal lateral stiffness, energy dissipation and deformation mode were analyzed. The results show that the beam ends can be formed by plastic hinges to deviate from the joint area to meet the seismic requirements of "strong joints". The displacement ductility coefficients of the whole specimen and the interlayer layer are greater than 4.05 and 4.81, respectively, corresponding to the maximum of equivalent viscous damping ratio of 0.288 and 0.286 respectively. The horizontal lateral stiffness of the specimen is uniformly distributed along the height. The lateral displacement and deformation show an ideal reverse triangular bending shear mode, and the failure mode of the specimen structure is an ideal plastic failure mechanism where the beam end weakens the section to yield fully to form a plastic hinge, and its bearing capacity decreases to 85% of the ultimate bearing capacity. The overall and interstory lateral displacement angles of the specimens are 0.043 3 rad and 0.039 4 radrespectively, which exceed the limit of 0.035 rads for the lateral displacement between the layers of the frame structures, which indicates that the tested structures have good seismic ductility.
【作者單位】: 蘇州科技大學江蘇省結構重點實驗室;蘇州建筑設計研究院有限公司;
【基金】:國家自然科學基金面上基金資助項目(51478286,51078247) 江蘇省“青藍工程”中青年學術帶頭人資助項目(2014) 江蘇省高校首批優(yōu)秀中青年教師出國研修計劃資助項目(2011)
【分類號】:TU352.11
【相似文獻】
相關期刊論文 前10條
1 柳炎樵;;中、薄鋼板變形的熱壓矯正[J];工業(yè)建筑;1964年06期
2 胡彥元;;用薄鋼板代替磚砌底模[J];建筑技術;1984年09期
3 余富明;;薄鋼板中性焰切割[J];建筑工人;1997年11期
4 ;非均勻升溫下薄鋼板的抗剪性能數(shù)值分析[J];鋼結構;2014年06期
5 ;神戶鋼鐵公司開發(fā)出建材用耐蝕性薄鋼板[J];鞍鋼技術;2002年01期
6 宋波;王利;羅曉玲;孫北東;許曉慧;;大型反應器加勁薄鋼板結構屈曲性能[J];北京科技大學學報;2010年08期
7 覃志清;姚建偉;;大面積薄鋼板平鋪焊接變形的控制技術[J];青島理工大學學報;2007年04期
8 吳波;劉春暉;趙新宇;劉瓊祥;;外置薄鋼板再生混合墻抗震性能試驗研究[J];建筑結構學報;2011年11期
9 彭桂蒸;張紀剛;韓建;鄧文艷;;大面積薄鋼板焊接殘余應力的試驗研究[J];低溫建筑技術;2010年08期
10 ;常溫和高溫下冷成型薄鋼板抗剪連接件的性能[J];鋼結構;2013年04期