【摘要】:人口的迅速增長(zhǎng)促進(jìn)了全球范圍內(nèi)的城市化進(jìn)程,城市建設(shè)用地的日益緊張催生越來越多的高層建筑甚至超高層建筑。同時(shí)一些國(guó)家和地區(qū)為了追求超高建筑所帶來的名片效應(yīng),正在規(guī)劃建設(shè)高度超過800m巨型建筑。我國(guó)計(jì)劃建設(shè)一座千米級(jí)巨型建筑使其成為下一個(gè)全球最高建筑,但目前世界上還沒有建成的千米級(jí)巨型建筑,許多研究領(lǐng)域仍處于空白階段。因此有必要對(duì)相關(guān)的建造技術(shù)展開研究,為我國(guó)建設(shè)全球最高建筑提供相應(yīng)的技術(shù)儲(chǔ)備。建筑高度是巨型建筑最為顯著的屬性,本研究重點(diǎn)關(guān)注寒區(qū)室外環(huán)境的垂直變化對(duì)建筑空調(diào)負(fù)荷和風(fēng)壓熱壓作用效果的影響,并以一座正在規(guī)劃當(dāng)中的設(shè)計(jì)案例為研究對(duì)象展開相關(guān)研究工作。首先,基于中尺度氣象模式WRFv3.4(Weather Research and Forecasting model)對(duì)建筑所在地區(qū)的氣象條件進(jìn)行模擬研究,并且采用當(dāng)?shù)貧庀笥^測(cè)得到的探空實(shí)驗(yàn)數(shù)據(jù)對(duì)模擬得到的氣象參數(shù)垂直分布進(jìn)行了驗(yàn)證,結(jié)果表明WRF模式對(duì)0~1000m高度范圍內(nèi)的氣象條件模擬性能良好。在此基礎(chǔ)之上,通過數(shù)據(jù)整理得到室外環(huán)境不同高度氣象參數(shù)相對(duì)于近地面高度氣象參數(shù)隨高度的變化規(guī)律,結(jié)果表明:在0~1000m高度范圍內(nèi),大氣溫度和壓力均隨著高度升高而線性降低;大氣相對(duì)濕度隨高度升高先線性升高后線性降低;風(fēng)速隨著高度升高先近似指數(shù)增大,后逐漸緩慢減小,最后略微增大。其次,根據(jù)模擬得到室外環(huán)境氣象參數(shù)的垂直變化規(guī)律,分別對(duì)大氣溫度、濕度、壓力進(jìn)行數(shù)據(jù)擬合,擬合得到不同高度氣象參數(shù)相對(duì)于近地面氣象參數(shù)隨高度變化的關(guān)系式。然后基于TRNSYS16瞬態(tài)模擬程序開發(fā)建立了巨型建筑空調(diào)負(fù)荷動(dòng)態(tài)方法,并將擬合得到的氣象參數(shù)與近地面氣象參數(shù)、高度的關(guān)系式導(dǎo)入空調(diào)負(fù)荷動(dòng)態(tài)模擬模型,對(duì)巨型建筑內(nèi)部不同高度標(biāo)準(zhǔn)層房間的空調(diào)負(fù)荷進(jìn)行動(dòng)態(tài)模擬,具體包括室內(nèi)負(fù)荷和新風(fēng)負(fù)荷。其中室內(nèi)負(fù)荷考慮不同高度、不同朝向、不同圍護(hù)結(jié)構(gòu)傳熱特性對(duì)室內(nèi)負(fù)荷的影響;新風(fēng)負(fù)荷同時(shí)考慮不同高度房間和不同高度新風(fēng)口對(duì)新風(fēng)負(fù)荷的影響。針對(duì)高度對(duì)空調(diào)負(fù)荷影響,分別定義了室內(nèi)負(fù)荷和新風(fēng)負(fù)荷的高度修正系數(shù),定量分析了高度對(duì)空調(diào)負(fù)荷的影響。此外,通過對(duì)新風(fēng)負(fù)荷隨房間高度和新風(fēng)口高度變化機(jī)理的分析,定義了室內(nèi)空氣密度影響因子和室內(nèi)外空氣焓差影響因子,定量分析了房間高度和新風(fēng)口高度對(duì)新風(fēng)負(fù)荷影響的比重。再次,根據(jù)模擬得到的0~1000m高度范圍內(nèi)的風(fēng)速垂直分布,整理得到建筑所在地風(fēng)速的垂直分布規(guī)律,并以此分布規(guī)律為基礎(chǔ)建立巨型建筑風(fēng)洞風(fēng)壓測(cè)試的風(fēng)速入口邊界條件,通過被動(dòng)模擬方法,在風(fēng)洞中模擬當(dāng)?shù)?~1000m高度范圍內(nèi)的風(fēng)廓,結(jié)合巨型建筑分段模型,對(duì)其外表面風(fēng)壓進(jìn)行了測(cè)試。此外,為了比較忽略高度適用性而采用標(biāo)準(zhǔn)大氣邊界層模型測(cè)得的風(fēng)壓與采用當(dāng)?shù)卣鎸?shí)風(fēng)廓所測(cè)風(fēng)壓的偏差,在風(fēng)洞中采用被動(dòng)模擬的方法模擬了B類地貌的標(biāo)準(zhǔn)大氣邊界層風(fēng)廓,并測(cè)試了其風(fēng)壓,進(jìn)而通過風(fēng)壓系數(shù)比較了采用兩種風(fēng)廓進(jìn)行風(fēng)壓測(cè)試得到結(jié)果的不同,研究發(fā)現(xiàn),如果以建筑頂部風(fēng)速作為風(fēng)壓系數(shù)計(jì)算的參考風(fēng)速,采用B類地貌標(biāo)準(zhǔn)風(fēng)廓所測(cè)的風(fēng)壓系數(shù)在巨型建筑較低樓層明顯偏小,在巨型建筑較高樓層差異不明顯。最后,結(jié)合風(fēng)洞實(shí)驗(yàn)測(cè)試得到的巨型建筑外表面風(fēng)壓系數(shù)分布,基于CONTAM3.2多區(qū)網(wǎng)絡(luò)模型對(duì)巨型建筑在風(fēng)壓與熱壓共同作用下的建筑內(nèi)部壓力垂直分布特性進(jìn)行了模擬研究,并且重點(diǎn)關(guān)注并分析各垂直和水平通道內(nèi)隔斷門兩側(cè)的壓力分布。另外,在對(duì)巨型建筑內(nèi)部熱壓控制策略定性分析的基礎(chǔ)上,對(duì)不同控制措施下作用在隔斷門上的壓力進(jìn)行對(duì)比分析,具體包括水平隔斷和垂直隔斷。通過與未采取任何控制措施的室內(nèi)壓力對(duì)比發(fā)現(xiàn),采用垂直隔斷相當(dāng)于降低了建筑高度,對(duì)各通道內(nèi)隔斷門兩側(cè)壓力的控制效果良好。本研究基于中尺度氣象模式WRFv3.4對(duì)寒區(qū)室外環(huán)境的垂直分布情況進(jìn)行了模擬,并基于此對(duì)室外環(huán)境垂直變化對(duì)巨型建筑的空調(diào)負(fù)荷和風(fēng)壓熱壓的影響展開相關(guān)研究。本文的研究方法可為與室外環(huán)境相關(guān)的建筑風(fēng)熱環(huán)境研究提供一些的借鑒,其研究成果可為巨型建筑的空調(diào)負(fù)荷預(yù)測(cè)和風(fēng)壓熱壓控制提供一些參考。
[Abstract]:The rapid growth of the population has promoted the process of urbanization around the world. More and more high-rise buildings and even super high-rise buildings are being generated by the increasing tension in urban construction land. At the same time, in order to pursue the business card effect of super high buildings, some countries and regions are planning to build a high degree of superstructure over 800m. Gigantic gigantic buildings have made it the next largest building in the world, but there are still no gigantic gigantic buildings in the world. Many research fields are still in the blank stage. Therefore, it is necessary to study the related construction techniques to provide the corresponding technical reserve for the construction of the highest building in the world. The height of the building is a giant building. The most significant attribute of this study is to focus on the influence of vertical change of outdoor environment on the effect of air conditioning load and pressure on the effect of the wind pressure on the effect of the effect of the effect of the building air conditioning load and pressure hot pressure. The research work is carried out on a planned design case. First, based on the mesoscale meteorological model WRFv3.4 (Weather Research and Forecasting model) ) to simulate the weather conditions in the area where the building is located, and to verify the vertical distribution of the simulated meteorological parameters using the local meteorological observation data. The results show that the WRF model has good simulation performance on the weather conditions in the high range of 0~1000m. On this basis, the data is collated to get the room. The results show that the atmospheric temperature and pressure decrease linearly with height in the 0~1000m height range, and the atmospheric relative humidity increases linearly with height, and the wind speed increases with the height rise first. Secondly, the vertical change law of meteorological parameters of outdoor environment is obtained by simulation, and the atmospheric temperature, humidity and pressure are fitted separately, and the relation between the weather parameters of different heights relative to the height of the near ground weather parameters is obtained, and then based on the TRNSYS16 transient simulation process. The dynamic method of air conditioning load of giant building is established in order to develop the dynamic simulation model of air conditioning load in the room with different height of the giant building, including indoor load and new wind load. The internal load takes into account the influence of different height, orientation, and heat transfer characteristics of different enclosure structures on the indoor load; the new wind load takes into account the influence of different height rooms and new air vent on the new wind load at the same time. In addition, through the analysis of the change mechanism of the new air load with the height of the room and the height of the new air vent, the influence factors of the indoor air density and the air enthalpy difference between indoor and outdoor are defined, and the proportion of the room height and the new air vent height to the new wind load is quantitatively analyzed. Again, according to the simulated 0~ The vertical distribution of wind speed in the 1000m height range is arranged to get the vertical distribution of the wind speed in the building. Based on this distribution law, the wind velocity entrance boundary condition of the wind tunnel test of the giant building is established. Through the passive simulation method, the wind profile in the local 0~1000m height range is simulated in the wind tunnel, and the segmented model of the giant building is combined. In addition, in order to compare the wind pressure measured by the standard atmospheric boundary layer model and the wind pressure measured by the local real wind profile, a passive simulation method is used to simulate the wind profile of the standard atmospheric boundary layer of B geomorphology in the wind tunnel, and the wind pressure is tested. By comparing the wind pressure coefficient, the results are different with the wind pressure test using two kinds of wind profiles. It is found that if the wind velocity is used as the reference wind speed of the wind pressure coefficient, the wind pressure coefficient measured by the B geomorphic standard wind profile is obviously smaller in the lower floor of the giant building, and the difference in the higher floor is not obvious in the mega building. Finally, based on the CONTAM3.2 multi zone network model, the vertical distribution characteristics of the internal pressure of the building under the joint action of wind pressure and hot press are simulated on the basis of the wind tunnel test, and the pressure on both sides of the vertical and horizontal passages is focused on and analyzed. In addition, on the basis of the qualitative analysis of the internal thermal pressure control strategy of the giant building, the pressure of the different control measures on the partition door is compared and analyzed, including the horizontal partition and the vertical partition. It is found that the vertical partition is equivalent to the reduction of the vertical partition by comparing with the indoor pressure that has not taken any control measures. The building height has good control effect on the pressure on both sides of the partition door. Based on the mesoscale meteorological model WRFv3.4, the vertical distribution of the outdoor environment in the cold region is simulated. Based on this, the influence of the vertical change of the outdoor environment on the air conditioning load and the pressure and hot pressure of the giant buildings is studied. The method can provide some reference for the research on the wind and heat environment related to the outdoor environment. The research results can provide some reference for the air conditioning load prediction and the wind pressure control of the mega buildings.

【學(xué)位授予單位】:哈爾濱工業(yè)大學(xué)
【學(xué)位級(jí)別】:博士
【學(xué)位授予年份】:2017
【分類號(hào)】:TU831.2

【相似文獻(xiàn)】

相關(guān)期刊論文 前10條

1 陳剛,李仲,劉澤華,王漢青;確定戶式空調(diào)負(fù)荷的方法探討[J];南華大學(xué)學(xué)報(bào)(理工版);2003年02期

2 鄭就;;中央空調(diào)負(fù)荷采用計(jì)算機(jī)軟件的計(jì)算與分析[J];制冷與空調(diào)(四川);2008年04期

3 劉馨宜;;空調(diào)負(fù)荷控制策略分析[J];科技資訊;2009年35期

4 盧麗;宗通;王國(guó)磊;;建筑遮擋對(duì)空調(diào)負(fù)荷影響的分析與探討[J];中國(guó)住宅設(shè)施;2011年02期

5 李斌;林弘宇;徐石明;顏慶國(guó);肖文舉;張磊;楊永標(biāo);;智能電網(wǎng)框架下公共樓宇空調(diào)負(fù)荷資源化應(yīng)用[J];供用電;2014年03期

6 李英娜,顧平道,莊琛;大中型商場(chǎng)空調(diào)負(fù)荷影響因素的探討[J];應(yīng)用能源技術(shù);2004年02期

7 溫權(quán),李敬如,趙靜;空調(diào)負(fù)荷計(jì)算方法及應(yīng)用[J];電力需求側(cè)管理;2005年04期

8 李東梅;李敬如;趙靜;溫權(quán);;北京空調(diào)負(fù)荷結(jié)構(gòu)及調(diào)控措施研究[J];電力技術(shù)經(jīng)濟(jì);2005年06期

9 李民;朱慰慈;;2005年夏季鎮(zhèn)江地區(qū)空調(diào)負(fù)荷特點(diǎn)分析[J];江蘇電機(jī)工程;2006年02期

10 楊潔;張旭;王凌飛;;上海世博會(huì)展館建筑空調(diào)負(fù)荷指標(biāo)的影響因素分析[J];暖通空調(diào);2006年09期

相關(guān)會(huì)議論文 前10條

1 張春路;李灝;丁國(guó)良;陳芝久;;空調(diào)負(fù)荷新型計(jì)算方法研究[A];上海市制冷學(xué)會(huì)一九九七年學(xué)術(shù)年會(huì)論文集[C];1997年

2 林真國(guó);付祥釗;張素云;;論由照明引起的空調(diào)負(fù)荷計(jì)算[A];全國(guó)暖通空調(diào)制冷2000年學(xué)術(shù)年會(huì)論文集[C];2000年

3 蔣騫;龍惟定;;雙層立面建筑的空調(diào)負(fù)荷計(jì)算[A];第13屆全國(guó)暖通空調(diào)技術(shù)信息網(wǎng)技術(shù)交流大會(huì)文集[C];2005年

4 龍洋波;吳祥生;孫秀平;;幾種常見空調(diào)負(fù)荷動(dòng)態(tài)計(jì)算方法介紹[A];2005西南地區(qū)暖通空調(diào)熱能動(dòng)力年會(huì)論文集[C];2005年

5 何大四;張旭;;改進(jìn)的季節(jié)性指數(shù)平滑法預(yù)測(cè)空調(diào)負(fù)荷實(shí)例研究[A];全國(guó)暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)資料摘要集(2)[C];2004年

6 周娟;陳友明;胡敏;;空調(diào)負(fù)荷計(jì)算新方法的應(yīng)用研究[A];全國(guó)暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)資料摘要集(2)[C];2004年

7 高立新;陸亞俊;;智能化空調(diào)負(fù)荷計(jì)算軟件的開發(fā)[A];全國(guó)暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)資料摘要集(2)[C];2004年

8 張春路;李灝;丁國(guó)良;陳芝久;;空調(diào)負(fù)荷新型計(jì)算方法研究[A];全國(guó)暖通空調(diào)制冷1998年學(xué)術(shù)年會(huì)論文集(2)[C];1998年

9 何大四;張旭;;改進(jìn)的季節(jié)性指數(shù)平滑法預(yù)測(cè)空調(diào)負(fù)荷的實(shí)例研究[A];上海市制冷學(xué)會(huì)二○○三年學(xué)術(shù)年會(huì)論文集[C];2003年

10 王春麗;李曉冬;;分層空調(diào)負(fù)荷與溫度場(chǎng)動(dòng)態(tài)多區(qū)熱質(zhì)平衡模型探討[A];全國(guó)暖通空調(diào)制冷2004年學(xué)術(shù)年會(huì)資料摘要集(2)[C];2004年

相關(guān)重要報(bào)紙文章 前10條

1 藍(lán)旺;給空調(diào)負(fù)荷“降溫”[N];中國(guó)電力報(bào);2004年

2 建文;國(guó)務(wù)院下發(fā)通知要求嚴(yán)格執(zhí)行公共建筑空調(diào)溫度控制標(biāo)準(zhǔn)[N];中華建筑報(bào);2007年

3 劉豐;福建將大力發(fā)展綠色建筑[N];建筑時(shí)報(bào);2014年

4 陳哲;26℃背后的節(jié)能之道[N];中華建筑報(bào);2007年

5 記者 劉月月;北京明確綠色建筑十項(xiàng)重點(diǎn)任務(wù)[N];中國(guó)建設(shè)報(bào);2013年

6 廣東建設(shè)報(bào)記者 談健;鄭愛軍:推行綠色建筑關(guān)鍵在大業(yè)主[N];廣東建設(shè)報(bào);2011年

7 南方日?qǐng)?bào)記者 謝慶!(shí)習(xí)生 吳曉彭;新樓能耗比老宅高10倍多[N];南方日?qǐng)?bào);2010年

8 南方日?qǐng)?bào)記者 謝慶裕;空調(diào)負(fù)荷將耗盡10個(gè)三峽電站[N];南方日?qǐng)?bào);2011年

9 ;空調(diào)負(fù)荷來勢(shì)兇猛 電網(wǎng)企業(yè)應(yīng)對(duì)有力[N];國(guó)家電網(wǎng)報(bào);2012年

10 馮海波邋通訊員 高凌波;標(biāo)志性建筑將更多“廣東建造”[N];廣東科技報(bào);2007年

相關(guān)博士學(xué)位論文 前7條

1 曹鈞亮;寒區(qū)巨型建筑空調(diào)負(fù)荷與風(fēng)壓熱壓特性研究[D];哈爾濱工業(yè)大學(xué);2017年

2 李洋;建筑能量系統(tǒng)熱力學(xué)分析與低?優(yōu)化研究[D];西安建筑科技大學(xué);2015年

3 韓天鶴;建筑圍護(hù)結(jié)構(gòu)與暖通空調(diào)能量系統(tǒng)熱力學(xué)基礎(chǔ)研究[D];湖南大學(xué);2015年

4 周智勇;建筑能耗定額的理論與實(shí)證研究[D];重慶大學(xué);2010年

5 龍恩深;建筑能耗基因理論研究[D];重慶大學(xué);2005年

6 徐斌;BuildingEnergy軟件開發(fā)及建筑圍護(hù)結(jié)構(gòu)輻射特性的優(yōu)化研究[D];中國(guó)科學(xué)技術(shù)大學(xué);2012年

7 楊小山;室外微氣候?qū)ㄖ照{(diào)能耗影響的模擬方法研究[D];華南理工大學(xué);2012年

相關(guān)碩士學(xué)位論文 前10條

1 尹璐;空調(diào)負(fù)荷特性分析及其對(duì)電壓穩(wěn)定性的影響[D];鄭州大學(xué);2015年

2 陸婷婷;空調(diào)負(fù)荷的儲(chǔ)能建模和控制策略研究[D];東南大學(xué);2015年

3 張榮祥;計(jì)及用戶舒適度的空調(diào)負(fù)荷參與電力系統(tǒng)頻率控制研究[D];山東大學(xué);2016年

4 謝威;電網(wǎng)友好型空調(diào)負(fù)荷的能效優(yōu)化管理方法研究[D];湖南大學(xué);2016年

5 王續(xù)芳;公共樓宇大規(guī)?照{(diào)負(fù)荷虛擬調(diào)峰關(guān)鍵技術(shù)研究[D];東南大學(xué);2016年

6 朱峰;空調(diào)負(fù)荷需求響應(yīng)特性及其調(diào)控策略研究[D];東南大學(xué);2016年

7 張志強(qiáng);基于電網(wǎng)側(cè)的空調(diào)負(fù)荷特性分析及其調(diào)控措施研究[D];華北電力大學(xué)(北京);2007年

8 糜作維;空調(diào)負(fù)荷的預(yù)測(cè)與建模[D];河海大學(xué);2006年

9 李育燕;空調(diào)負(fù)荷的特性分析與建模[D];河海大學(xué);2004年

10 寧勇飛;夏熱冬冷地區(qū)住宅空調(diào)負(fù)荷特征與節(jié)能分析[D];南華大學(xué);2006年

,

本文編號(hào):1849109

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/jianzhugongchenglunwen/1849109.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶c0078***提供,本站僅收錄摘要或目錄,作者需要?jiǎng)h除請(qǐng)E-mail郵箱bigeng88@qq.com