群體高層建筑模型風洞試驗阻塞效應的修正
發(fā)布時間:2018-01-04 01:35
本文關鍵詞:群體高層建筑模型風洞試驗阻塞效應的修正 出處:《同濟大學學報(自然科學版)》2017年01期 論文類型:期刊論文
【摘要】:基于單體高層建筑模型的尾流面積法,提出了適用于群體高層建筑模型風洞試驗阻塞效應的修正方法.給出了群體建筑的流場模式和基本假定,推導了修正公式,將尾流面積法的適用范圍推廣到同時布置兩個或多個建筑的阻塞效應的修正.利用均勻流中典型周邊布置方案的等高雙建筑和等高三建筑的風洞試驗結果進行參數(shù)擬合,并在不同工況下驗證了修正方法.該方法可在較高精度范圍內滿足工程項目的需要.
[Abstract]:Based on the wake area method of single high-rise building model, a modified method for blocking effect in wind tunnel test of group high-rise building model is proposed, and the flow field model and basic assumptions of group building are given. The modified formula is derived. In this paper, the applicable range of wake area method is extended to modify the blocking effect of two or more buildings arranged at the same time. The wind tunnel test results of two or three buildings with typical peripheral arrangement in uniform flow are used for reference. Number fit. At the same time, the modified method is verified under different working conditions, which can meet the needs of engineering projects in a higher precision range.
【作者單位】: 同濟大學土木工程防災國家重點實驗室;上海市政工程設計研究總院(集團)有限公司;
【基金】:國家自然科學基金(91215302,90715040) 土木工程防災國家重點實驗室自主研究課題基金(SLDRCE15-A-04)
【分類號】:TU973.213
【正文快照】: 隨著城鎮(zhèn)化的發(fā)展,建筑周邊通常存在體型較大或數(shù)量密集的周邊建筑群.因此在風洞試驗中阻塞比往往較大,從而導致試驗結果失準.對于超高層建筑或大跨屋蓋結構而言,在強風作用下結構的風荷載是結構安全性和適用性的控制荷載之一[1].為了獲得準確的風荷載,降低試驗阻塞比尤為重要