DX-600水冷發(fā)射機“冷卻故障”分析與應急處理
發(fā)布時間:2018-09-18 18:22
【摘要】:在發(fā)射機維護的過程中發(fā)現(xiàn),對于水冷的DX發(fā)射機來講,"冷卻故障"出現(xiàn)時,PB單元或發(fā)射機將直接關機,除非故障排除手動開機,嚴重威脅安全播出。本文通過對"冷卻故障"進行原理性的分析,結合典型故障,對PB200單元出現(xiàn)的"冷卻故障",以及在觸摸屏(MMI)上的顯示,完整地總結了引起冷卻故障的原因及應急處理方法。
[Abstract]:In the course of transmitter maintenance, it is found that, for water-cooled DX transmitter, when "cooling failure" occurs, the unit or transmitter will be shut down directly unless the malfunction is removed by manual operation, which seriously threatens the safety of broadcasting. Through the principle analysis of "cooling fault", combined with typical fault, the "cooling fault" of PB200 unit and the display on touch screen (MMI), this paper summarizes the cause of cooling fault and emergency treatment method.
【作者單位】: 國家新聞出版廣電總局953臺;
【分類號】:TN838
本文編號:2248735
[Abstract]:In the course of transmitter maintenance, it is found that, for water-cooled DX transmitter, when "cooling failure" occurs, the unit or transmitter will be shut down directly unless the malfunction is removed by manual operation, which seriously threatens the safety of broadcasting. Through the principle analysis of "cooling fault", combined with typical fault, the "cooling fault" of PB200 unit and the display on touch screen (MMI), this paper summarizes the cause of cooling fault and emergency treatment method.
【作者單位】: 國家新聞出版廣電總局953臺;
【分類號】:TN838
【相似文獻】
相關期刊論文 前2條
1 董明;DX-600發(fā)射機射頻功放模塊的維護[J];廣播與電視技術;2003年11期
2 ;[J];;年期
相關會議論文 前1條
1 馮東亮;;基于單片機的DX-600發(fā)射機冷卻控制系統(tǒng)的研究與設計[A];中國新聞技術工作者聯(lián)合會第六次會員代表大會、2014年學術年會暨第七屆《王選新聞科學技術獎》和優(yōu)秀論文獎頒獎大會論文集(三等獎)[C];2014年
,本文編號:2248735
本文鏈接:http://sikaile.net/kejilunwen/wltx/2248735.html