COIL中碘氣動(dòng)閥可靠性增長試驗(yàn)的初步研究
本文關(guān)鍵詞:COIL中碘氣動(dòng)閥可靠性增長試驗(yàn)的初步研究 出處:《強(qiáng)激光與粒子束》2016年10期 論文類型:期刊論文
更多相關(guān)文章: 碘氣動(dòng)閥 可靠性增長 Weibull分布
【摘要】:對(duì)COIL中的碘氣動(dòng)閥進(jìn)行可靠性增長試驗(yàn),主要包括可靠性增長模型的討論,試驗(yàn)方案設(shè)計(jì)、數(shù)據(jù)分析與處理等工作,提出了基于碘氣動(dòng)閥密封組件的改造措施,并進(jìn)行了可靠性驗(yàn)證試驗(yàn),試驗(yàn)結(jié)果表明經(jīng)可靠性增長試驗(yàn)后,碘氣動(dòng)閥的可靠性有了較大提高。在此基礎(chǔ)上分析得出了基于碘氣動(dòng)閥的可靠性增長模型。
[Abstract]:The reliability growth test of iodine pneumatic valve in COIL includes the discussion of reliability growth model, the design of test scheme, the analysis and processing of data and so on. The improvement measures based on iodine pneumatic valve seal assembly are put forward and the reliability verification test is carried out. The test results show that after reliability growth test. The reliability of the iodine pneumatic valve has been greatly improved, and the reliability growth model based on the iodine pneumatic valve is obtained.
【作者單位】: 西北核技術(shù)研究所;中國科學(xué)院大連化學(xué)物理研究所;
【基金】:國家重點(diǎn)實(shí)驗(yàn)室基金項(xiàng)目(SKLLIM1003)
【分類號(hào)】:TN248.5
【正文快照】: COIL是目前波長最短的化學(xué)激光器,在高能激光領(lǐng)域占有重要的一席之地。隨著COIL實(shí)用化進(jìn)程的發(fā)展,人們對(duì)其各單元的要求也越來越高,各裝置的工作可靠性成為了激光器的重要優(yōu)化指標(biāo)。碘氣動(dòng)閥作為COIL系統(tǒng)中的重要核心部件,其主要功能是控制碘罐內(nèi)的飽和碘蒸氣進(jìn)入光學(xué)增益腔的
【相似文獻(xiàn)】
相關(guān)期刊論文 前3條
1 鄭殿峰;楊義勇;王家驊;;吸氣式脈沖爆震發(fā)動(dòng)機(jī)鈍體氣動(dòng)閥的設(shè)計(jì)與實(shí)驗(yàn)研究[J];北京大學(xué)學(xué)報(bào)(自然科學(xué)版);2012年03期
2 吳建星;白春華;;氣動(dòng)發(fā)聲的數(shù)值計(jì)算[J];彈箭與制導(dǎo)學(xué)報(bào);2007年05期
3 ;[J];;年期
相關(guān)重要報(bào)紙文章 前1條
1 李黎翔;要善于運(yùn)用精神激勵(lì)[N];中國石化報(bào);2003年
相關(guān)博士學(xué)位論文 前2條
1 宮繼雙;提高氣動(dòng)閥式脈沖爆震發(fā)動(dòng)機(jī)性能的技術(shù)研究[D];南京航空航天大學(xué);2012年
2 劉鴻;六管氣動(dòng)閥式兩相脈沖爆震發(fā)動(dòng)機(jī)試驗(yàn)研究[D];南京航空航天大學(xué);2010年
相關(guān)碩士學(xué)位論文 前2條
1 李春野;小型PDE兩相摻混特性的研究[D];南京航空航天大學(xué);2009年
2 劉玉杰;核電廠氣動(dòng)閥可靠性研究與維修策略的建立[D];上海交通大學(xué);2007年
,本文編號(hào):1394673
本文鏈接:http://sikaile.net/kejilunwen/dianzigongchenglunwen/1394673.html