35kV變電站繼電保護系統(tǒng)的設計與應用

發(fā)布時間:2018-11-22 19:06
【摘要】:如今,在電力系統(tǒng)的不斷發(fā)展和電網(wǎng)安全穩(wěn)定運行前提下,電能給國民經(jīng)濟和社會發(fā)展帶來了巨大動力和效益。但是,電力系統(tǒng)在運行中,往往會由于自然或者人為因素造成電氣設備發(fā)生絕緣損壞、斷線、過負荷等情況,使電網(wǎng)進入異常運行狀態(tài)。如果不能及時有效控制,就會引起電力系統(tǒng)震蕩,供電穩(wěn)定失衡,甚至使電網(wǎng)瓦解,并導致大面積停電,造成嚴重后果。為了防止事故發(fā)生,現(xiàn)代化智能變電站電氣設備上都安裝繼電保護裝置,電力系統(tǒng)繼電保護是自動切除故障設備和消除異常情況的技術與裝備,對電力系統(tǒng)的維護具有很大的意義。本論文以真實事故案例作為出發(fā)點,結(jié)合原始數(shù)據(jù),將設備接線方式(內(nèi)橋接線與單母分段接線)進行詳細的研究與對比,確定適合的一次接線方案(35kV側(cè)內(nèi)橋,10kV側(cè)單母分段);對電路進行分析,運用兩種運行方式(最大運行方式、最小運行方式)計算出短路電流、設備及線路的保護定值,并進行整定計算與校驗;研究分析真實事故發(fā)生的原因,進一步提高對電力系統(tǒng)繼電保護的認識,得出電力系統(tǒng)繼電保護的配置與定值,并對改善電力系統(tǒng)繼電保護靈敏度提出自己的看法,進一步闡明如何保證電網(wǎng)安全及供電穩(wěn)定。
[Abstract]:Nowadays, with the continuous development of power system and the safe and stable operation of power grid, electric energy has brought huge power and benefit to the national economy and social development. However, in the operation of electric power system, the electrical equipment will often be damaged, broken and overloaded due to natural or human factors, which makes the power network enter into abnormal operation state. If it can not be controlled in time and effectively, it will cause the power system oscillation, power supply stability imbalance, even make the power network collapse, and lead to a large area of power outages, resulting in serious consequences. In order to prevent accidents, modern intelligent substations are equipped with relay protection devices. The relay protection of power system is the technology and equipment to automatically remove the fault equipment and eliminate the abnormal situation. It is of great significance to the maintenance of power system. This paper takes the real accident case as the starting point, unifies the original data, carries on the detailed research and the contrast to the equipment wiring way (the internal bridge and the single bus segment connection), determines the suitable primary connection scheme (35kV side internal bridge), 10kV); The circuit is analyzed, and the short-circuit current, equipment and circuit protection setting are calculated by using two operation modes (maximum operation mode and minimum operation mode), and the setting calculation and verification are carried out. This paper studies and analyzes the causes of real accidents, further improves the understanding of power system relay protection, obtains the configuration and fixed value of power system relay protection, and puts forward its own views on improving the sensitivity of power system relay protection. Further expound how to ensure the security of power grid and power supply stability.
【學位授予單位】:河北科技大學
【學位級別】:碩士
【學位授予年份】:2017
【分類號】:TM63;TM77

【參考文獻】

相關期刊論文 前5條

1 趙孟;;電力系統(tǒng)繼電保護技術現(xiàn)狀與展望[J];電子技術與軟件工程;2016年04期

2 孫瑩;;電力系統(tǒng)繼電保護技術的現(xiàn)狀及其發(fā)展研究[J];山東工業(yè)技術;2014年13期

3 馮秀賓;;智能變電站的涵義及發(fā)展探討[J];高壓電器;2013年02期

4 修黎明;高湛軍;黃德斌;唐毅;;智能變電站二次系統(tǒng)設計方法研究[J];電力系統(tǒng)保護與控制;2012年22期

5 邸榮光;劉仕兵;;光電式電流互感器技術的研究現(xiàn)狀與發(fā)展[J];電力自動化設備;2006年08期

相關碩士學位論文 前9條

1 郭勇;220kV智能變電站繼電保護配置分析與研究[D];華北電力大學(北京);2016年

2 李智;秦皇島西區(qū)110kV智能變電站設計[D];燕山大學;2016年

3 何曉宇;35KV變電站繼電保護設計與整定[D];東北石油大學;2016年

4 鄒文君;110KV變電站繼電保護的配置及整定計算[D];大連理工大學;2014年

5 林海鋒;智能變電站的線路保護測控裝置的應用設計[D];山東大學;2013年

6 馮晗;泰安地區(qū)110kV智能變電站設計[D];華北電力大學;2013年

7 舒佳;變壓器微機差動保護測控裝置的研究與設計[D];西安工程大學;2012年

8 顧工川;35kV數(shù)字化變電站的設計[D];南昌大學;2012年

9 趙雪菲;110kV變電站設計[D];華北電力大學;2012年



本文編號:2350270

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/2350270.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶4dce1***提供,本站僅收錄摘要或目錄,作者需要刪除請E-mail郵箱bigeng88@qq.com