復(fù)雜情況下架空輸電線路參數(shù)在線校準(zhǔn)方法研究
[Abstract]:As an important part of power system, the accuracy of transmission line parameters plays an important role in the safe and stable operation of the system. This paper analyzes the characteristics of several equivalent models of single-circuit transmission lines, establishes the zero-sequence lumped parameter model of multi-circuit transmission lines, and transforms the equivalent circuit equations of the model, which lays a theoretical foundation for the calibration of transmission line parameters. The calculation method of transmission line sequence component is deduced by using the basic principles of engineering electromagnetism. The influence of the new transmission line at different intervals on the original transmission line parameters is analyzed by using the calculation method and electromagnetic simulation software respectively, and the accuracy of the calculation method is verified. At the same time, the influence of electromagnetic coupling on the parameters of the original transmission line is summarized. In view of the parallel new transmission lines near the running transmission lines, the on-line calibration method of the parameters of multi-circuit transmission lines is studied. According to different line combinations, a specific parameter calibration scheme is proposed. The parameters of the original line after the new ground line are modified by electromagnetic theory calculation method, and the voltage and current phasor of transmission line are measured synchronously by the incremental method. The zero-sequence parameters of multi-circuit transmission lines are calculated by using lumped parameter model of multi-circuit transmission lines, and the parameters of multi-circuit transmission lines measured are decoupled by using the decoupling method of transmission line parameters with complete parallelism at the head and end of transmission lines. Calibrate original line parameters. The simulation model of transmission line parameter calibration is established for different transmission line combinations. The accuracy of transmission line parameter calibration method is verified by simulating and analyzing the on-line calibration method of transmission line parameters.
【學(xué)位授予單位】:華北電力大學(xué)
【學(xué)位級別】:碩士
【學(xué)位授予年份】:2017
【分類號】:TM75
【參考文獻(xiàn)】
相關(guān)期刊論文 前10條
1 趙進(jìn)全;尹建華;夏建生;趙艷軍;劉桓瑞;高巖;;一種非對稱輸電線路參數(shù)的在線測量方法[J];西安交通大學(xué)學(xué)報(bào);2016年02期
2 趙艷軍;陳曉科;尹建華;趙進(jìn)全;李賀龍;姜良剛;;一種新型的同塔雙回輸電線路工頻阻抗參數(shù)測量方法[J];電工技術(shù)學(xué)報(bào);2015年02期
3 張斌;陳水明;莊池杰;張波;鄧世聰;;同塔雙回輸電線路電氣不平衡度的改善措施[J];電網(wǎng)技術(shù);2014年12期
4 任正某;孫振權(quán);汪雨辰;;同桿雙回輸電線路換位方式的比較[J];電氣技術(shù);2014年11期
5 吳靜文;張龍偉;曹保江;朱軍;吳廣寧;石超群;;特高壓交流同塔雙回輸電線路電磁耦合分量的計(jì)算分析[J];中國電力;2014年06期
6 牛勝鎖;張達(dá);梁志瑞;霍曉娣;;基于抗差總體最小二乘法的電力系統(tǒng)諧波狀態(tài)估計(jì)[J];電力系統(tǒng)保護(hù)與控制;2014年11期
7 梁志瑞;宮瑞邦;牛勝鎖;趙飛;張思為;;雙回耦合輸電線路的零序參數(shù)在線測量[J];電力自動化設(shè)備;2013年07期
8 趙艷軍;陳曉科;尹建華;趙進(jìn)全;李賀龍;姜良剛;;一種新的輸電線路工頻阻抗參數(shù)測試儀研制[J];陜西電力;2013年06期
9 展伯平;;中小型防爆電機(jī)的噪聲控制[J];產(chǎn)業(yè)與科技論壇;2012年10期
10 牛勝鎖;梁志瑞;張建華;蘇海鋒;;基于多時(shí)段同步測量信息的T接線路參數(shù)在線測量[J];電工技術(shù)學(xué)報(bào);2012年05期
相關(guān)博士學(xué)位論文 前1條
1 牛勝鎖;面向配電網(wǎng)的廣域測量關(guān)鍵技術(shù)研究及系統(tǒng)開發(fā)[D];華北電力大學(xué);2013年
相關(guān)碩士學(xué)位論文 前10條
1 霍曉娣;多回并行輸電線路工頻參數(shù)混合測量方法研究[D];華北電力大學(xué);2015年
2 郎凱;500kV輸電線路工頻參數(shù)的測量與計(jì)算[D];華北電力大學(xué);2013年
3 秦文龍;輸電線路參數(shù)測量的研究[D];西南交通大學(xué);2011年
4 潘雪;輸電線路參數(shù)在線計(jì)算方法研究[D];重慶大學(xué);2011年
5 趙德奎;架空輸電線路工頻參數(shù)測量研究[D];西南交通大學(xué);2010年
6 易楊;高壓同塔多回輸電線路參數(shù)計(jì)算及軟件的設(shè)計(jì)與研究[D];華中科技大學(xué);2009年
7 吳尊東;輸電線路工頻參數(shù)變頻抗干擾測試的研究[D];浙江大學(xué);2009年
8 牛勝鎖;基于GPS的電力系統(tǒng)交流電量同步采集器的研究[D];華北電力大學(xué)(河北);2005年
9 薛志英;輸電線路工頻參數(shù)在線測量方法的研究[D];華北電力大學(xué)(河北);2005年
10 徐瑋;輸電線路參數(shù)測量及諧波分析系統(tǒng)(參數(shù)測量部分)研究[D];武漢大學(xué);2004年
,本文編號:2138720
本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/2138720.html