DG接入配電網(wǎng)的通信式自適應電流保護研究
發(fā)布時間:2018-07-06 10:57
本文選題:DG + 配電網(wǎng)繼電保護 ; 參考:《煤炭工程》2017年10期
【摘要】:分析了分布式電源(DG)并入配電網(wǎng)后,傳統(tǒng)的接線結構由單電源供電網(wǎng)絡變?yōu)榱硕嚯娫垂╇娋W(wǎng)絡,改變了系統(tǒng)的潮流分布,繼而配電網(wǎng)繼電保護出現(xiàn)不協(xié)調的問題。針對DG并網(wǎng)后帶來的誤動、拒動和靈敏度降低等一系列問題,提出了一種通信式自適應電流保護方法,采用GOOSE over UDP實現(xiàn)信息傳輸并和自適應電流整定方法相結合,解決了DG接入配電網(wǎng)帶來的問題。
[Abstract]:After distributed generation (DG) is incorporated into distribution network, the traditional wiring structure is changed from single power supply network to multi-source power supply network, which changes the power flow distribution of the system, and then the distribution of relay protection in distribution network is not coordinated. A communication adaptive current protection method is proposed to solve a series of problems, such as maloperation, rejection and sensitivity decrease after DG is connected to power grid. Goose over UDP is used to realize information transmission and combine with adaptive current setting method. The problem caused by DG access to distribution network is solved.
【作者單位】: 中國礦業(yè)大學信息與電氣工程學院;
【基金】:江蘇省自然科學基金項目(BK20130187) 國家留學基金(201406425007)