天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

當(dāng)前位置:主頁(yè) > 科技論文 > 電氣論文 >

壓縮感知理論在小電流接地故障選線中的應(yīng)用

發(fā)布時(shí)間:2018-05-18 20:28

  本文選題:小電流接地系統(tǒng) + 故障選線; 參考:《西南交通大學(xué)》2016年碩士論文


【摘要】:小電流接地系統(tǒng)憑借自身優(yōu)越的供電可靠性,得以在國(guó)內(nèi)中低壓配電網(wǎng)中被廣泛采用?墒,單相接地故障現(xiàn)象在電網(wǎng)中發(fā)生的頻率較高,由于發(fā)生單相接地故障時(shí)產(chǎn)生的故障電流很小、選線獲取的樣本數(shù)據(jù)過(guò)多造成選線時(shí)間長(zhǎng)、故障信號(hào)的精確獲取難等很多因素,對(duì)于單相接地故障選線這個(gè)難題,很長(zhǎng)時(shí)間以來(lái)都在尋找相應(yīng)的有效對(duì)策。怎樣才能使得故障線路的排除過(guò)程變得更加準(zhǔn)確、快速,無(wú)疑是非常重要且意義深遠(yuǎn)的。本文針對(duì)這一難題,圍繞開(kāi)展相關(guān)研究工作,在人們已有的大量研究基礎(chǔ)上,進(jìn)一步探索和完善故障選線方法,彌補(bǔ)現(xiàn)有選線方式存在的不足。先針對(duì)小電流接地系統(tǒng)發(fā)生單相接地故障時(shí)會(huì)有哪些突出的特點(diǎn)顯現(xiàn)出來(lái),本文對(duì)此展開(kāi)了較為具體的討論和梳理,并且就穩(wěn)態(tài)以及暫態(tài)兩個(gè)方面,歸納總結(jié)了故障特征量在非故障線路與故障線路上所存在的不同之處。以此為后續(xù)的研究分析做好充足的準(zhǔn)備以及鋪好扎實(shí)的理論基礎(chǔ)。其次介紹了當(dāng)前已經(jīng)存在的幾種傳統(tǒng)選線方式,分析它們目前各自面對(duì)著哪些約束,并對(duì)這些方法中所存在問(wèn)題及缺陷進(jìn)行歸納。最后,通過(guò)以上的分析和研究說(shuō)明,如果要使得最初的故障分析更加精確快速、使得選線更加準(zhǔn)確,那么剛開(kāi)始對(duì)于故障信號(hào)的精確獲取是非常重要的。當(dāng)前采用暫態(tài)分量來(lái)對(duì)線路進(jìn)行故障判斷的方法,很多是通過(guò)線路的零序量所存在的特征差異來(lái)判斷的,而傳統(tǒng)的高速采樣有可能會(huì)使部分高頻分量發(fā)生折疊,導(dǎo)致信號(hào)混淆。因此能否獲得更加精確的零序量關(guān)系著選線的成敗,但是只有達(dá)到了高速的采樣頻率才能使得故障信號(hào)的獲取更加準(zhǔn)確。本文對(duì)一種剛剛興起的全新的數(shù)據(jù)采集方法壓縮感知理論進(jìn)行分析研究,并將其應(yīng)用于小電流單相接地故障選線中,從根本上解決采樣率限制的問(wèn)題,精確獲取故障信號(hào),從而提高故障選線的準(zhǔn)確度。本文通過(guò)應(yīng)用一種較新的壓縮感知理論,嘗試實(shí)現(xiàn)在采樣頻率上的突破,使得故障選線方法不再受其條件的約束,然后獲取精確的恢復(fù)信號(hào)。除此之外,還將該理論與希爾伯特一黃變換(HHT)相融合,建立仿真模型并驗(yàn)證該選線方法在不同類型下小電流接地故障選線的正確性以及可靠性,獲得了預(yù)期的效果。
[Abstract]:Low-current grounding system is widely used in medium-low-voltage distribution network because of its superior power supply reliability. However, the frequency of single-phase grounding fault is high in the power network. Because the fault current generated by single-phase grounding fault is very small and the sample data of line selection is too much, the line selection time is long. There are many factors such as the difficulty of obtaining the fault signal accurately. For a long time the problem of single-phase grounding fault line selection has been looking for the corresponding effective countermeasures. How to make the troubleshooting process more accurate and rapid is undoubtedly very important and far-reaching. In view of this problem, this paper focuses on the related research work, on the basis of a large number of existing research, further exploration and improvement of fault line selection methods, to make up for the shortcomings of the existing methods of line selection. In this paper, the characteristics of single-phase grounding fault in low-current grounding system are discussed and combed in detail, and the steady state and transient state are discussed as well. The differences of fault characteristics between non-fault lines and fault lines are summarized. This is the following research and analysis to make adequate preparation and lay a solid theoretical foundation. Secondly, this paper introduces several existing traditional route selection methods, analyzes the constraints they face at present, and sums up the problems and defects in these methods. Finally, through the above analysis and research, if we want to make the initial fault analysis more accurate and fast, and make the line selection more accurate, it is very important to obtain the fault signal at the beginning. At present, the transient component is used to judge the fault of the transmission line, many of them are judged by the characteristic difference of the zero-sequence quantity of the line, while the traditional high-speed sampling may make part of the high-frequency component fold and cause the signal confusion. Therefore, the success of line selection depends on whether or not a more accurate zero sequence can be obtained, but only with a high sampling frequency can the fault signal be obtained more accurately. In this paper, a new data acquisition method, compression sensing theory, is analyzed and studied, and it is applied to the fault line selection of single-phase earthing fault with small current. The problem of limiting the sampling rate is solved fundamentally and the fault signal is obtained accurately. In order to improve the accuracy of fault line selection. By applying a new compression sensing theory, this paper attempts to achieve a breakthrough in the sampling frequency so that the fault line selection method is no longer constrained by its conditions, and then the accurate recovery signal is obtained. In addition, the theory is combined with Hilbert-Huang transform (HHT) to establish a simulation model and verify the correctness and reliability of this method in different types of low-current grounding fault line selection. The expected results are obtained.
【學(xué)位授予單位】:西南交通大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2016
【分類號(hào)】:TM862

【相似文獻(xiàn)】

相關(guān)期刊論文 前10條

1 苑舜;張磊;蔡志遠(yuǎn);宋云東;;電纜網(wǎng)故障選線方法的研究[J];高壓電器;2011年01期

2 張鈞;何正友;賈勇;;基于S變換的故障選線新方法[J];中國(guó)電機(jī)工程學(xué)報(bào);2011年10期

3 李原;廖海斌;;基于小波包多頻帶相關(guān)分析的故障選線方法[J];安徽科技學(xué)院學(xué)報(bào);2011年04期

4 苑舜;張磊;蔡志遠(yuǎn);宋云東;;電纜網(wǎng)故障選線方法的研究[J];電工文摘;2011年03期

5 王林川;史雪峰;陳寶生;;基于灰靶理論在諧振接地故障選線中的應(yīng)用[J];電測(cè)與儀表;2012年02期

6 黃景光;劉會(huì)家;呂艷萍;;基于冗余表決的行波小波系數(shù)極大值極性法配電網(wǎng)接地故障選線原理研究[J];繼電器;2006年07期

7 朱珂;裴佑楠;陳晨;徐文遠(yuǎn);;自適應(yīng)控流型故障選線方案[J];電工技術(shù)學(xué)報(bào);2009年08期

8 黑曉紅;;經(jīng)消弧線圈接地系統(tǒng)故障選線保護(hù)[J];甘肅科技;2010年09期

9 王彥文;左忠祥;徐康勇;楊凡信;;基于5次諧波的混沌檢測(cè)原理的故障選線方法的研究[J];電氣應(yīng)用;2011年08期

10 李濤濤;何金朋;郭們君;;基于網(wǎng)絡(luò)數(shù)據(jù)共享的小波包故障選線方法研究[J];電工技術(shù);2011年12期

相關(guān)會(huì)議論文 前7條

1 張凱;袁兆強(qiáng);范李平;;基于模糊粗糙集理論的故障選線融合技術(shù)研究[A];中國(guó)高等學(xué)校電力系統(tǒng)及其自動(dòng)化專業(yè)第二十四屆學(xué)術(shù)年會(huì)論文集(中冊(cè))[C];2008年

2 張偉剛;張保會(huì);胡海松;徐靖東;;小波包分析在配電網(wǎng)故障選線中的應(yīng)用[A];中國(guó)高等學(xué)校電力系統(tǒng)及其自動(dòng)化專業(yè)第二十四屆學(xué)術(shù)年會(huì)論文集(中冊(cè))[C];2008年

3 熊志偉;蔡金錠;;6~35kV配電網(wǎng)電纜系統(tǒng)的故障選線方法[A];2008中國(guó)電力系統(tǒng)保護(hù)與控制學(xué)術(shù)研討會(huì)論文集[C];2008年

4 戴宇;;暫態(tài)行波在小電流接地故障選線中的應(yīng)用[A];貴州省電機(jī)工程學(xué)會(huì)2010年優(yōu)秀論文集[C];2010年

5 龐清樂(lè);曹銀杰;穆健;郎豐法;;基于粗集理論的小電流接地系統(tǒng)故障選線研究[A];2006年首屆ICT大會(huì)信息、知識(shí)、智能及其轉(zhuǎn)換理論第一次高峰論壇會(huì)議論文集[C];2006年

6 呂曉平;楊志偉;張?chǎng)?史英;;基于小波奇異熵的小電流接地故障選線新方法[A];山東電機(jī)工程學(xué)會(huì)第五屆供電專業(yè)學(xué)術(shù)交流會(huì)論文集[C];2008年

7 高志鵬;;小電流接地系統(tǒng)接地故障選線與定位研究的創(chuàng)新理論與應(yīng)用[A];山東省石油學(xué)會(huì)油田電力、通信及自動(dòng)化技術(shù)研討會(huì)優(yōu)秀工程技術(shù)論文集[C];2009年

相關(guān)博士學(xué)位論文 前7條

1 劉洋;配電網(wǎng)電纜線路故障檢測(cè)與故障源定位方法研究[D];沈陽(yáng)工業(yè)大學(xué);2015年

2 高利;諧振接地系統(tǒng)故障選線與定位方法研究[D];昆明理工大學(xué);2015年

3 李德臣;基于可拓理論的小電流故障選線方法研究[D];中國(guó)礦業(yè)大學(xué);2010年

4 王念彬;基于小波神經(jīng)網(wǎng)絡(luò)的小電流接地系統(tǒng)故障選線方法的研究[D];中國(guó)礦業(yè)大學(xué)(北京);2010年

5 龐清樂(lè);基于智能算法的小電流接地故障選線研究[D];山東大學(xué);2007年

6 周志成;基于多源信息融合的模糊決策故障選線判據(jù)及裝置研究[D];華中科技大學(xué);2007年

7 柯碩灝;配網(wǎng)故障自診自愈新原理與新方法研究[D];華中科技大學(xué);2011年

相關(guān)碩士學(xué)位論文 前10條

1 鄭韻如;基于k-means聚類分析的配電網(wǎng)故障選線方法[D];昆明理工大學(xué);2015年

2 黨義鵬;基于暫態(tài)特征的諧振接地故障選線方法的研究[D];遼寧工業(yè)大學(xué);2016年

3 顧偉揚(yáng);小電流接地系統(tǒng)接地故障選線定位方法的研究[D];東南大學(xué);2015年

4 許寧;基于HHT與分形維數(shù)的配電網(wǎng)故障選線研究[D];東北電力大學(xué);2016年

5 郭曉霞;有源全補(bǔ)償消弧裝置中相似度故障選線技術(shù)研究[D];湖北工業(yè)大學(xué);2016年

6 張小潔;基于PSO-SVM的小電流接地系統(tǒng)故障選線方法[D];河南理工大學(xué);2015年

7 王怡軒;適用于高阻接地故障的諧振接地系統(tǒng)故障選線技術(shù)研究[D];山東大學(xué);2016年

8 楊雪蓮;壓縮感知理論在小電流接地故障選線中的應(yīng)用[D];西南交通大學(xué);2016年

9 李蒙;中壓配電網(wǎng)故障選線研究[D];鄭州大學(xué);2016年

10 趙磊;基于模糊神經(jīng)網(wǎng)絡(luò)的配電網(wǎng)故障選線方法研究[D];山東理工大學(xué);2016年

,

本文編號(hào):1907093

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/1907093.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶a780f***提供,本站僅收錄摘要或目錄,作者需要?jiǎng)h除請(qǐng)E-mail郵箱bigeng88@qq.com