天堂国产午夜亚洲专区-少妇人妻综合久久蜜臀-国产成人户外露出视频在线-国产91传媒一区二区三区

當(dāng)前位置:主頁 > 科技論文 > 電氣論文 >

基于突變電容值的高壓直流輸電線路的故障定位

發(fā)布時(shí)間:2018-01-20 15:03

  本文關(guān)鍵詞: VSC-HVDC 故障定位 零模網(wǎng)絡(luò) 識(shí)別電容 Bergeron模型 出處:《新疆大學(xué)》2017年碩士論文 論文類型:學(xué)位論文


【摘要】:為了滿足現(xiàn)代電網(wǎng)的發(fā)展需求,柔性高壓直流輸電系統(tǒng)逐漸被采用,柔性高壓直流輸電系統(tǒng)采用全控型器件IGBT,它可以實(shí)現(xiàn)系統(tǒng)電流的自關(guān)斷,相對(duì)于傳統(tǒng)的高壓直流輸電系統(tǒng),柔性高壓直流輸電系統(tǒng)可以向無源網(wǎng)絡(luò)供電,遠(yuǎn)距離的孤立負(fù)荷,因此柔性直流輸電系統(tǒng)勢(shì)必將要不斷地發(fā)展。而在高壓直流輸電系統(tǒng)中,線路一般都比較長(zhǎng),并且運(yùn)行環(huán)境惡劣,所以與其他輸電設(shè)備相比故障率比較高。為了保障直流輸電系統(tǒng)的安全穩(wěn)定運(yùn)行,需要在直流線路發(fā)生故障時(shí),及時(shí)確定故障點(diǎn)位置并且清除故障,因此精確的故障定位方法是十分必要的。通過對(duì)兩種常用的故障測(cè)距方法即單端測(cè)距法和雙端測(cè)距法的比較,選用雙端測(cè)距法對(duì)直流線路上的單極接地故障進(jìn)行故障測(cè)距;根據(jù)VSC-HVDC系統(tǒng)中的主要元件的特性,對(duì)直流輸電線路的接地故障需要應(yīng)用的VSC-HVDC的零模網(wǎng)絡(luò)和1模網(wǎng)絡(luò)進(jìn)行了比較;文中通過零模網(wǎng)絡(luò)與1模網(wǎng)絡(luò)的仿真圖,得出了柔性直流輸電系統(tǒng)中的部分結(jié)構(gòu)在零模網(wǎng)絡(luò)中等效網(wǎng)絡(luò)圖,從而得出在零模網(wǎng)絡(luò)中,VSC-HVDC系統(tǒng)中的整流器部分可以等效為并聯(lián)電容的結(jié)論,提出了基于突變電容值的故障定位原理;為了比較零模電壓、零模電流和識(shí)別電容之間的關(guān)系,還需要將零模網(wǎng)絡(luò)中的電壓電流分量進(jìn)行解耦,通過解耦后的電壓電流分量來計(jì)算出零模識(shí)別電容的數(shù)值;為了研究直流線路上發(fā)生故障時(shí),故障行波波頭到達(dá)的時(shí)刻,文中在PSCAD中搭建了直流輸電線路,對(duì)于柔性直流輸電系統(tǒng)的整流部分和換流部分采用的是PSCAD軟件中自帶的模型;對(duì)于直流線路的模型搭建選擇的是遠(yuǎn)方終止模式的搭建方式,輸電線路分布參數(shù)模型選用的是Bergeron模型;最后在搭建好的直流線路模型上進(jìn)行單極接地故障的仿真,在全長(zhǎng)100kM,額定直流電壓為±110kV的直流線路上進(jìn)行故障設(shè)置,比較零模電壓、零模電流和識(shí)別電容的突變圖形在直流線路上不同的位置上且經(jīng)不同的過渡電阻的情況下發(fā)生的變化,從而得出結(jié)論,即在零模網(wǎng)絡(luò)中,基于突變電容值的故障定位能夠可靠識(shí)別故障發(fā)生后故障行波波頭到達(dá)的時(shí)刻,并且不受故障距離,電氣量波形漸變的影響以及能適應(yīng)經(jīng)不同過渡電阻的高阻接地故障。
[Abstract]:In order to meet the needs of the development of modern power grid, the flexible HVDC transmission system is gradually adopted. The full control device IGBT is used in the flexible HVDC transmission system, which can realize the self-turn-off of the system current. Compared with the traditional HVDC system, the flexible HVDC system can supply power to the passive network with long distance isolated load. Therefore, the flexible direct current transmission system is bound to continue to develop, but in the HVDC transmission system, the lines are generally longer, and the operating environment is poor. Therefore, compared with other transmission equipment, the failure rate is higher. In order to ensure the safe and stable operation of HVDC system, it is necessary to determine the location of the fault point and clear the fault in time when the DC line fault occurs. Therefore, accurate fault location method is very necessary. Through the comparison of two common fault location methods, one end location method and two end location method. The fault location of unipolar grounding fault on DC line is carried out by using two-terminal location method. According to the characteristics of main components in VSC-HVDC system, the zero-mode network and 1-mode network of VSC-HVDC which need to be applied to ground fault of HVDC transmission line are compared. In this paper, through the simulation diagram of zero-mode network and 1-mode network, the equivalent network diagram of some structures of flexible direct current transmission system in zero-mode network is obtained, and then the equivalent network diagram in zero-mode network is obtained. The conclusion that the rectifier part of VSC-HVDC system can be equivalent to parallel capacitance is put forward, and the fault location principle based on the value of abrupt capacitance is put forward. In order to compare the relationship between zero-mode voltage, zero-mode current and recognition capacitance, it is necessary to decouple the voltage and current components in zero-mode network. The zero-mode recognition capacitance is calculated by decoupling the voltage and current components. In order to study the arrival time of the fault wave head on the DC line, a DC transmission line is built in PSCAD. For the rectifier part and commutation part of the flexible direct current transmission system, the model included in PSCAD software is adopted. For the DC line model, the remote termination mode is chosen, and the transmission line distribution parameter model is the Bergeron model. Finally, the single-pole grounding fault simulation is carried out on the established DC line model. The fault setting is carried out on the DC line with a total length of 100kM and rated DC voltage of 鹵110kV, and the zero-mode voltage is compared. The change of the zero mode current and the abrupt pattern of the recognition capacitance in different position on the DC line and the different transition resistance, thus the conclusion is drawn, that is, in the zero mode network. The fault location based on the abrupt capacitance value can reliably identify the arrival time of the fault traveling wave head after the fault occurs, and can not be subjected to the fault distance. The influence of the gradual change of electrical waveform and the ability to adapt to the high resistance grounding fault through different transition resistance.
【學(xué)位授予單位】:新疆大學(xué)
【學(xué)位級(jí)別】:碩士
【學(xué)位授予年份】:2017
【分類號(hào)】:TM755

【參考文獻(xiàn)】

相關(guān)期刊論文 前10條

1 徐海洋;宋國(guó)兵;樊占峰;靳幸福;;行波波頭的參數(shù)識(shí)別方法在高壓直流輸電系統(tǒng)中的應(yīng)用[J];西安交通大學(xué)學(xué)報(bào);2016年02期

2 高本鋒;董沛毅;劉辛?xí)?張學(xué)偉;張?jiān)茣?馬玉龍;趙書強(qiáng);;高壓直流輸電線路微分欠壓保護(hù)特性與定值整定[J];電網(wǎng)技術(shù);2015年08期

3 蔣冠前;李志勇;楊慧霞;楊靜;;柔性直流輸電系統(tǒng)拓?fù)浣Y(jié)構(gòu)研究綜述[J];電力系統(tǒng)保護(hù)與控制;2015年15期

4 關(guān)紅兵;黃立濱;劉濤;李書勇;田慶;;高壓直流輸電系統(tǒng)直流差動(dòng)保護(hù)的改進(jìn)及仿真[J];南方電網(wǎng)技術(shù);2015年06期

5 劉劍;邰能靈;范春菊;;基于電流波形匹配的高壓直流輸電線路縱聯(lián)保護(hù)[J];電網(wǎng)技術(shù);2015年06期

6 劉誠(chéng)斌;;關(guān)于高壓直流輸電線路的故障定位分析[J];科技視界;2015年14期

7 饒宏;李凌飛;許樹楷;;2014年國(guó)際大電網(wǎng)會(huì)議學(xué)術(shù)動(dòng)態(tài)系列報(bào)道高壓直流輸電和電力電子技術(shù)[J];電力系統(tǒng)自動(dòng)化;2015年06期

8 于洋;孫學(xué)鋒;高鵬;劉興華;陳勇強(qiáng);劉琳;;高壓直流輸電線路暫態(tài)保護(hù)分析與展望[J];電力系統(tǒng)保護(hù)與控制;2015年02期

9 何軍娜;陳劍云;艾穎梅;林鵬;馮秋實(shí);;電力系統(tǒng)行波測(cè)距方法及其發(fā)展[J];電力系統(tǒng)保護(hù)與控制;2014年24期

10 韓昆侖;蔡澤祥;徐敏;賀智;;高壓直流輸電線路微分欠壓保護(hù)特征量動(dòng)態(tài)特性分析與整定[J];電力自動(dòng)化設(shè)備;2014年02期

相關(guān)會(huì)議論文 前1條

1 尤敏;張保會(huì);張嵩;張偉剛;;高壓直流輸電線路保護(hù)的現(xiàn)狀和展望[A];中國(guó)高等學(xué)校電力系統(tǒng)及其自動(dòng)化專業(yè)第二十四屆學(xué)術(shù)年會(huì)論文集(中冊(cè))[C];2008年

相關(guān)博士學(xué)位論文 前2條

1 徐敏;直流線路繼電保護(hù)解析分析方法與新型保護(hù)原理研究[D];華南理工大學(xué);2014年

2 吳大立;輸電線路保護(hù)新原理及實(shí)現(xiàn)技術(shù)的研究[D];華中科技大學(xué);2008年

相關(guān)碩士學(xué)位論文 前7條

1 王娟娟;VSC-HVDC系統(tǒng)典型故障仿真與分析[D];西安建筑科技大學(xué);2015年

2 張?jiān)糯?基于HHT的小電流接地系統(tǒng)故障行波定位研究[D];蘭州交通大學(xué);2014年

3 張映鴻;基于Hilbert-Huang變換的高壓直流輸電線路保護(hù)研究[D];華南理工大學(xué);2013年

4 潘偉明;高壓直流輸電線路的行波保護(hù)研究[D];南京理工大學(xué);2013年

5 蘇黎;高壓直流輸電對(duì)交流系統(tǒng)暫態(tài)穩(wěn)定影響的研究[D];西南交通大學(xué);2008年

6 董鑫;高壓直流輸電線路行波保護(hù)的研究[D];東北電力大學(xué);2008年

7 李學(xué)鵬;高壓直流輸電線路行波保護(hù)及其故障定位的研究[D];華北電力大學(xué)(北京);2006年

,

本文編號(hào):1448634

資料下載
論文發(fā)表

本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/1448634.html


Copyright(c)文論論文網(wǎng)All Rights Reserved | 網(wǎng)站地圖 |

版權(quán)申明:資料由用戶77ddc***提供,本站僅收錄摘要或目錄,作者需要?jiǎng)h除請(qǐng)E-mail郵箱bigeng88@qq.com