【摘要】:風(fēng)電機(jī)組的基礎(chǔ)整體抗扭剛度是復(fù)合地基基礎(chǔ)設(shè)計(jì)的一項(xiàng)關(guān)鍵性參數(shù)。通過應(yīng)用ANSYS建立有限元模型并對結(jié)構(gòu)進(jìn)行分析,提取和變換相應(yīng)的剛度矩陣,確定包括地基在內(nèi)的風(fēng)機(jī)基礎(chǔ)扭轉(zhuǎn)剛度,最后與根據(jù)規(guī)范計(jì)算得到的結(jié)果進(jìn)行比對驗(yàn)證,可知該簡化的有限元方法可靠、有效,提供了一個(gè)對于計(jì)算復(fù)合基礎(chǔ)扭轉(zhuǎn)剛度行之有效的方法。
[Abstract]:The overall torsional stiffness of wind turbine is a key parameter in the design of composite foundation. The finite element model is established by using ANSYS and the structure is analyzed and the corresponding stiffness matrix is extracted and transformed. The torsional stiffness of fan foundation including foundation is determined and compared with the calculated results according to the code, the simplified finite element method is proved to be reliable and effective. An effective method for calculating torsional stiffness of composite foundation is provided.
【作者單位】: 水能資源利用關(guān)鍵技術(shù)湖南省重點(diǎn)實(shí)驗(yàn)室;中國電建集團(tuán)中南勘測設(shè)計(jì)研究院有限公司;
【分類號】:TM614
【正文快照】: 0引言近幾年來,我國風(fēng)力發(fā)電事業(yè)發(fā)展迅速,風(fēng)力發(fā)電總裝機(jī)容量顯著增加,但機(jī)組的安全事故也時(shí)有發(fā)生,風(fēng)機(jī)基礎(chǔ)的剛度與其結(jié)構(gòu)安全性具有直接聯(lián)系。在當(dāng)前的風(fēng)電場設(shè)計(jì)中,風(fēng)電機(jī)組生產(chǎn)廠商一般是基于一個(gè)假定的基礎(chǔ)扭轉(zhuǎn)剛度提出上部荷載,因此會(huì)對基礎(chǔ)的抗扭剛度提出明確的要求