基于IEC61850智能變電站改擴建方案研究與實踐
發(fā)布時間:2017-12-26 21:24
本文關鍵詞:基于IEC61850智能變電站改擴建方案研究與實踐 出處:《華北電力大學(北京)》2016年碩士論文 論文類型:學位論文
【摘要】:自國網公司2009年提出建設“堅強智能電網”以來,目前在國網系統內已建成各電壓等級的新建、改擴建智能變電站1500余座。隨著智能電網建設的快速推進,智能變電站已面臨大量的檢修的任務,同時也面臨智能變電站擴建、改建等工作需求。智能變電站網絡化的信息傳輸、設備間耦合度緊密、配置文件的應用使二次系統檢修、擴建和改造過程中設備間安全隔離困難,安全措施抽象化、復雜化,這給智能變電站的檢修、擴建和改造工作帶來了極大的安全風險,增加了實施難度;尤其是變電站改、擴建過程中,站內配置文件的變化,導致相關設備和回路受影響,影響范圍的確定和回路的驗證困難,大大增加了檢修、擴建和改造工作的實施難度。針對上述問題,本文對首先分析了國家電網公司典型的智能變電站繼電保護配置模式,并與常規(guī)變電站“明顯電氣斷開點”的安全措施技術相比,分析了智能變電站二次回路各種安全隔離技術的特點;結合現場工程實踐經驗,闡述了智能變電站繼電保護現場作業(yè)時安全措施應遵循的原則,并以典型的220千伏線路保護、500千伏主變保護間隔為例,闡述了在設備定校、缺陷處理等不同現場作業(yè)時所需的二次安全措施;在此基礎上,分析了智能變電站擴建策略和相關安全措施,并以杭州220千伏文津變改擴建工程為例,驗證改擴建策略的正確性和相關安全措施的可靠性;最后,結合智能變電站智能終端改建工作,提出了智能終端改建技術方案,以最大程度減少因改建工程造成的一次設備停役時間。
[Abstract]:Since the construction of "strong smart grid" in 2009 by the State Grid Corporation of China, there are more than 1500 smart substations newly built, expanded or expanded at all voltage levels in the State Grid system. With the rapid development of smart grid construction, smart substations have been faced with a lot of maintenance tasks, and are also facing the needs of expansion and reconstruction of smart substations. The application of information transmission equipment, intelligent substation network coupling between closely, configuration files make two system maintenance, expansion and transformation in the process equipment security isolation security measures difficult, abstract, complex, intelligent substation maintenance, the expansion and renovation work has brought great security risk, increased the difficulty of implementation; especially the substation renovation and expansion process, change station configuration files, related to equipment and circuit affected, and to determine the effect of loop range verification difficult, greatly increased the difficulty of maintenance, expansion and renovation work. Aiming at the above problems, this paper analyzes the typical national Power Grid Corp of intelligent substation relay protection configuration mode, and compared with the conventional substation technical safety measures "clear electrical disconnection point", analyzes the characteristics of smart substation secondary circuit two kinds of security isolation technology; based on the engineering practice experience, expounded the intelligent substation relay protection field work safety measures should follow the principle of taking the typical 220 thousand volt and 500 thousand volt line protection transformer protection interval as an example, describes the two safety measures required in equipment calibration and defect treatment of different field operations; on this basis, analysis of the expansion strategy of intelligent substation and the related security measures. Taking Hangzhou 220 thousand volt Wenjin change expansion project as an example, to verify the reliability and validity of the expansion strategy of relevant safety measures; finally, combined with the wisdom Can the substation intelligent terminal reconstruction work, put forward the intelligent terminal reconstruction technical scheme, in order to minimize the time of equipment shutdown due to the reconstruction project.
【學位授予單位】:華北電力大學(北京)
【學位級別】:碩士
【學位授予年份】:2016
【分類號】:TM63;TM76
【相似文獻】
相關期刊論文 前10條
1 洪天p,
本文編號:1338872
本文鏈接:http://sikaile.net/kejilunwen/dianlidianqilunwen/1338872.html
教材專著