某大型物流倉庫自動噴水滅火系統(tǒng)設計參數(shù)的設定與探析
發(fā)布時間:2018-10-24 17:58
【摘要】:結合實際工程,對早期抑制快速響應(ESFR)自動噴水滅火系統(tǒng)在某大型物流倉庫中的應用進行了簡要闡述,并對系統(tǒng)的設計參數(shù)進行了探析,尤其是對穩(wěn)高壓供水系統(tǒng)中穩(wěn)壓泵的流量、揚程及氣壓水罐有效容積的設定提出了設計建議。
[Abstract]:Combined with the actual project, the application of the early suppression of rapid response (ESFR) automatic sprinkler system in a large logistics warehouse is briefly described, and the design parameters of the system are analyzed. In particular, the design suggestions for the setting of flow rate, head and effective volume of pressure tank in stable high pressure water supply system are put forward.
【作者單位】: 中國移動通信集團設計院有限公司;中國建筑設計院有限公司;
【分類號】:TU892
本文編號:2292124
[Abstract]:Combined with the actual project, the application of the early suppression of rapid response (ESFR) automatic sprinkler system in a large logistics warehouse is briefly described, and the design parameters of the system are analyzed. In particular, the design suggestions for the setting of flow rate, head and effective volume of pressure tank in stable high pressure water supply system are put forward.