毛細管柱氣相色譜法測定工作場所空氣中環(huán)己酮
發(fā)布時間:2018-09-10 14:05
【摘要】:目的建立工作場所空氣中環(huán)己酮的毛細管柱氣相色譜測定方法。方法采用活性炭管采集空氣樣品,以二硫化碳解吸,經(jīng)FFAP毛細管色譜柱分離后,以火焰離子化檢測器檢測,標(biāo)準(zhǔn)曲線法定量。結(jié)果環(huán)己酮在質(zhì)量濃度為10.00~1 000.00 mg/L時呈線性關(guān)系,相關(guān)系數(shù)為0.999 9,檢出限和定量下限分別為1.31和4.37 mg/L,最低檢出濃度和最低定量濃度分別為4.37和13.11 mg/m~3(以采集1.5 L工作場所空氣計算);平均解吸效率為95.80%~97.88%。批內(nèi)、批間相對標(biāo)準(zhǔn)偏差分別為0.52%~3.12%和3.28%~4.75%。樣品在室溫下可保存7 d。結(jié)論本方法操作簡單、準(zhǔn)確度高,適用于大批量樣品的測定。
[Abstract]:Objective to establish a capillary column gas chromatography method for the determination of cyclohexanone in workplace air. Methods the air samples were collected by activated carbon tube and desorbed by carbon disulfide. The samples were separated by FFAP capillary column and detected by flame ionization detector. Results there was a linear relationship between cyclohexanone and cyclohexanone at 000.00 mg/L. The correlation coefficient was 0.999, the detection limit and the lower limit of quantification were 1.31 and 4.37 mg/L, respectively, the minimum detectable concentration and the minimum quantitative concentration were 4.37 and 13.11 mg/m~3, respectively, and the average desorption efficiency was 95.80 and 97.88, respectively. The relative standard deviations between batches were 0.52% and 3.28%, respectively. The samples can be preserved for 7 days at room temperature. Conclusion this method is simple, accurate and suitable for the determination of mass samples.
【作者單位】: 武漢科技大學(xué)醫(yī)學(xué)院公共衛(wèi)生學(xué)院"職業(yè)危害識別與控制"湖北省重點實驗室;
【分類號】:O657.71;R134.4
本文編號:2234656
[Abstract]:Objective to establish a capillary column gas chromatography method for the determination of cyclohexanone in workplace air. Methods the air samples were collected by activated carbon tube and desorbed by carbon disulfide. The samples were separated by FFAP capillary column and detected by flame ionization detector. Results there was a linear relationship between cyclohexanone and cyclohexanone at 000.00 mg/L. The correlation coefficient was 0.999, the detection limit and the lower limit of quantification were 1.31 and 4.37 mg/L, respectively, the minimum detectable concentration and the minimum quantitative concentration were 4.37 and 13.11 mg/m~3, respectively, and the average desorption efficiency was 95.80 and 97.88, respectively. The relative standard deviations between batches were 0.52% and 3.28%, respectively. The samples can be preserved for 7 days at room temperature. Conclusion this method is simple, accurate and suitable for the determination of mass samples.
【作者單位】: 武漢科技大學(xué)醫(yī)學(xué)院公共衛(wèi)生學(xué)院"職業(yè)危害識別與控制"湖北省重點實驗室;
【分類號】:O657.71;R134.4
【相似文獻】
相關(guān)期刊論文 前3條
1 李少旦;彭衛(wèi)芳;;石墨爐原子吸收光譜法測定工作場所空氣中鉻及其化合物[J];理化檢驗(化學(xué)分冊);2012年03期
2 向靜;茍勇;;超聲浸取—原子吸收法測定工作場所空氣中鉛 鎘及化合物[J];微量元素與健康研究;2014年05期
3 王金鳳;趙敏;王千;陳月萌;童月嬋;;毛細管柱氣相色譜法同時測定工作場所空氣中7種有機物[J];理化檢驗(化學(xué)分冊);2014年08期
,本文編號:2234656